<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>http://rpm.rcabc.org/index.php?action=history&amp;feed=atom&amp;title=ASM_Panel_Page_Template_%28for_Active_Members%29</id>
	<title>ASM Panel Page Template (for Active Members) - Revision history</title>
	<link rel="self" type="application/atom+xml" href="http://rpm.rcabc.org/index.php?action=history&amp;feed=atom&amp;title=ASM_Panel_Page_Template_%28for_Active_Members%29"/>
	<link rel="alternate" type="text/html" href="http://rpm.rcabc.org/index.php?title=ASM_Panel_Page_Template_(for_Active_Members)&amp;action=history"/>
	<updated>2026-04-28T23:57:19Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.31.1</generator>
	<entry>
		<id>http://rpm.rcabc.org/index.php?title=ASM_Panel_Page_Template_(for_Active_Members)&amp;diff=51940&amp;oldid=prev</id>
		<title>James Klassen at 17:34, 25 June 2025</title>
		<link rel="alternate" type="text/html" href="http://rpm.rcabc.org/index.php?title=ASM_Panel_Page_Template_(for_Active_Members)&amp;diff=51940&amp;oldid=prev"/>
		<updated>2025-06-25T17:34:08Z</updated>

		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;__NOTOC__&lt;br /&gt;
__NONUMBEREDHEADINGS__&lt;br /&gt;
{{DISPLAYTITLE:&amp;lt;span style=&amp;quot;position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);&amp;quot;&amp;gt;{{FULLPAGENAME}}&amp;lt;/span&amp;gt;}}&lt;br /&gt;
&lt;br /&gt;
&amp;lt;big&amp;gt;&amp;lt;big&amp;gt;Division C - Accepted Materials&amp;lt;/big&amp;gt;&amp;lt;/big&amp;gt;&lt;br /&gt;
&amp;lt;hr&amp;gt;&lt;br /&gt;
&amp;lt;big&amp;gt;&amp;lt;big&amp;gt;&amp;lt;big&amp;gt;&amp;lt;big&amp;gt;&amp;lt;big&amp;gt;Panel Name&amp;lt;/big&amp;gt;&amp;lt;/big&amp;gt;&amp;lt;/big&amp;gt;&amp;lt;/big&amp;gt;&amp;lt;/big&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;big&amp;gt;&amp;lt;big&amp;gt;&amp;lt;big&amp;gt;by Active Member Name&amp;lt;/big&amp;gt;&amp;lt;/big&amp;gt;&amp;lt;/big&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
| style=&amp;quot;background-color: #ffffcc; column-width:100%&amp;quot; | The metal panel listed and described below is accepted for use in the '''''RoofStar Guarantee Program'''''.&lt;br /&gt;
|}&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
;Manufacturer: (Active Member Name here)&lt;br /&gt;
;Contact Address: See the current Membership list and contact information at [http://www.rcabc.org/members/find-a-member/ www.rcabc.org]&lt;br /&gt;
;Product Group: Standing Seam Metal Roof System&lt;br /&gt;
;Panel Machine: Machine Name (Model number)&lt;br /&gt;
;Accepted for the ''RoofStar Guarantee Program'': Date here&lt;br /&gt;
;Accepted for application in: Water-shedding Roof Systems&lt;br /&gt;
;Panel Name: Name&lt;br /&gt;
;Seam Type: Type&lt;br /&gt;
&lt;br /&gt;
The roofing assembly / material information published below and in the [http://{{SERVERNAME}}/index.php?title=Main_Page RCABC Roofing Practices Manual] DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority.  For more information about this product or system, consult the manufacturer.&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
====OVERVIEW====&lt;br /&gt;
(The following overview is boilerplate wording and can be modified to suit the specific panel description.&lt;br /&gt;
The (panel name) metal panel is formed with an on-site/in shop continuous metal roofing panel roll forming machine (Machine name). This machine produces a standing seam panel with a seam height of XX mm (XX&amp;quot;) and profiles can vary from XX mm (XX&amp;quot;) wide up to XX mm (XX&amp;quot;) wide.&lt;br /&gt;
&lt;br /&gt;
On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities in lengths up to XXX'.&lt;br /&gt;
&lt;br /&gt;
====SYSTEM DESCRIPTION====&lt;br /&gt;
&amp;lt;ol&amp;gt;&lt;br /&gt;
&amp;lt;li&amp;gt;'''General''': The (panel name) metal panel is secured with concealed fastener.&lt;br /&gt;
&amp;lt;li&amp;gt;'''Seam Height''': XX mm (XX&amp;quot;)&lt;br /&gt;
&amp;lt;li&amp;gt;'''Panel Widths''': XX mm (XX&amp;quot;) wide up to XX mm (XX&amp;quot;) wide&lt;br /&gt;
&amp;lt;li&amp;gt;'''Maximum Length''': XX m (XX')&lt;br /&gt;
&amp;lt;li&amp;gt;'''Range of Application''': Installed on wood or steel sloped roofs, in commercial, institutional, industrial and residential construction. For re-roofing or new construction.&lt;br /&gt;
&amp;lt;li&amp;gt;'''Panel Attachment''': Fastening is site specific, engineer must confirm fixing specifications.&lt;br /&gt;
&amp;lt;li&amp;gt;'''Fasteners (Screws)''': &lt;br /&gt;
&amp;lt;ol&amp;gt;&lt;br /&gt;
&amp;lt;li&amp;gt;Fasteners used to attach panel clips to steel must be No. XX-XX by XX mm (X&amp;quot;) long self-drilling, (screw type - i.e., self-tapping pancake head plated steel) screws.  Use (i.e., two fasteners per panel clip), inserted into panel clip guide holes.&lt;br /&gt;
&amp;lt;li&amp;gt;Fasteners used to attach panel clips to plywood must be No. XX-XX by XX mm (X&amp;quot;) long (screw type - i.e., self-tapping pancake head plated steel) screws for wood. Use (i.e., two fasteners per panel clip), inserted into panel clip guide holes.&lt;br /&gt;
&amp;lt;/li&amp;gt;&amp;lt;/ol&amp;gt;&lt;br /&gt;
&amp;lt;li&amp;gt;'''Panel Clips''': One piece assembly XX mm (X&amp;quot;) wide, XX mm (X&amp;quot;) high, manufactured by (name of panel manufacturer) (or approved equal). Minimum thickness 0.022 in. (No. 22 MSG). Clips spaced maximum 600 mm (24&amp;quot;) O.C., or as specified on engineered shop drawings (Ref. Standard for Architectural Sheet Metal (ASM) Roof Systems, [http://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#3.1.3.3._Resistance_to_Specified_Wind_Loads  Article 3.1.3.3.] and [http://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#3.1.3.5._Submittals Article 3.1.3.5.]).&lt;br /&gt;
&amp;lt;li&amp;gt;'''Deck Requirements''': in keeping with the [http://rpm.rcabc.org/index.php?title=Standard_for_Architectural_Sheet_Metal_(ASM)_Systems Standard for Architectural Sheet Metal (ASM) Systems].&lt;br /&gt;
&amp;lt;/li&amp;gt;&amp;lt;/ol&amp;gt;&lt;br /&gt;
&lt;br /&gt;
====PROFILE====&lt;br /&gt;
N/A&lt;br /&gt;
&lt;br /&gt;
====TECHNICAL DATA SHEET====&lt;br /&gt;
N/A&lt;br /&gt;
&lt;br /&gt;
====SITE CONDITIONS====&lt;br /&gt;
Minimum roof slope is 1:6 (2&amp;quot; in 12&amp;quot;). Severe conditions (heavy snow or ice) minimum slope is 1:1.5 (8&amp;quot; in 12&amp;quot;).&lt;br /&gt;
&lt;br /&gt;
====PERFORMANCE REQUIREMENTS====&lt;br /&gt;
&amp;lt;ol&amp;gt;&lt;br /&gt;
&amp;lt;li&amp;gt;'''Wind Uplift Resistance''': Panel securement shall conform to the requirements in [https://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#PART_3 Part 3] of the [http://rpm.rcabc.org/index.php?title=Standard_for_Architectural_Sheet_Metal_(ASM)_Systems Standard for Architectural Sheet Metal (ASM) Systems].&lt;br /&gt;
&amp;lt;li&amp;gt;'''Materials''':RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the requirements published in [https://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#Section_9.2._Materials Section 9.2.] of the Standard.&lt;br /&gt;
&amp;lt;/li&amp;gt;&amp;lt;/ol&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;hr&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[[Architectural Metal Roofing|&amp;lt;i class=&amp;quot;fa fa-chevron-circle-left fa&amp;quot; &amp;gt;&amp;lt;/i&amp;gt; Back to ''Site-Formed Metal Roofing Systems'']]&lt;br /&gt;
&lt;br /&gt;
[[Materials by Product Type|&amp;lt;i class=&amp;quot;fa fa-chevron-circle-left fa&amp;quot; &amp;gt;&amp;lt;/i&amp;gt; Back to ''Accepted Materials'']]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[[Main Page|Home]]&lt;/div&gt;</summary>
		<author><name>James Klassen</name></author>
		
	</entry>
</feed>