<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>http://rpm.rcabc.org/index.php?action=history&amp;feed=atom&amp;title=Working_Page_3</id>
	<title>Working Page 3 - Revision history</title>
	<link rel="self" type="application/atom+xml" href="http://rpm.rcabc.org/index.php?action=history&amp;feed=atom&amp;title=Working_Page_3"/>
	<link rel="alternate" type="text/html" href="http://rpm.rcabc.org/index.php?title=Working_Page_3&amp;action=history"/>
	<updated>2026-04-29T08:10:41Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.31.1</generator>
	<entry>
		<id>http://rpm.rcabc.org/index.php?title=Working_Page_3&amp;diff=52238&amp;oldid=prev</id>
		<title>James Klassen at 21:50, 26 September 2025</title>
		<link rel="alternate" type="text/html" href="http://rpm.rcabc.org/index.php?title=Working_Page_3&amp;diff=52238&amp;oldid=prev"/>
		<updated>2025-09-26T21:50:39Z</updated>

		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{{DISPLAYTITLE:&amp;lt;span style=&amp;quot;position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);&amp;quot;&amp;gt;{{FULLPAGENAME}}&amp;lt;/span&amp;gt;}}&lt;br /&gt;
__NOTOC__&lt;br /&gt;
&lt;br /&gt;
&amp;lt;big&amp;gt;&amp;lt;big&amp;gt;Division D - Construction Details&amp;lt;/big&amp;gt;&amp;lt;/big&amp;gt;&lt;br /&gt;
&amp;lt;hr&amp;gt;&lt;br /&gt;
&amp;lt;big&amp;gt;&amp;lt;big&amp;gt;&amp;lt;big&amp;gt;&amp;lt;big&amp;gt;&amp;lt;big&amp;gt;SBS | Window Opening ([[SBS_Roof_Systems_Standard#10.3.4.5._Doors.2C_Windows.2C_and_Wall_Openings | Article 10.3.4.5.]])&amp;lt;/big&amp;gt;&amp;lt;/big&amp;gt;&amp;lt;/big&amp;gt;&amp;lt;/big&amp;gt;&amp;lt;/big&amp;gt;&lt;br /&gt;
{{Template:Construction Details Header}}&lt;br /&gt;
&amp;lt;div class=&amp;quot;panel panel-success&amp;quot;&amp;gt;&lt;br /&gt;
&amp;lt;div class=&amp;quot;panel-heading&amp;quot;&amp;gt;&amp;lt;big&amp;gt;'''SBS Details'''&amp;lt;/big&amp;gt;&amp;lt;/div&amp;gt;&lt;br /&gt;
&amp;lt;div class=&amp;quot;panel-body&amp;quot;&amp;gt;&lt;br /&gt;
&amp;lt;div class=&amp;quot;col-md-6&amp;quot;&amp;gt;&lt;br /&gt;
&amp;lt;div style=&amp;quot;text-align:center; vertical-align:center&amp;quot;&amp;gt;&lt;br /&gt;
[[File:10.3.3.6.jpg|link=http://rpm.rcabc.org/images/6/6f/10.3.3.6.jpg | class=img-responsive]]&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&amp;lt;/div&amp;gt;&amp;lt;!-- COL-MD-6 --&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div class=&amp;quot;col-md-6&amp;quot;&amp;gt;&lt;br /&gt;
=== WORK INCLUDED ===&lt;br /&gt;
&lt;br /&gt;
;(1) [[SBS Roof Systems Standard#PART_9|'''Primary Roof Membrane''']]: Installed per ''RoofStar Guarantee Standards''. &lt;br /&gt;
;(2) [[SBS Roof Systems Standard#PART_10|'''Membrane Flashing''']]: Carried up walls a minimum 200 mm (8&amp;quot;) above roof surface. At window curbs membrane flashing must be 200mm (8&amp;quot;) in height above the top of extruded polystyrene insulation or protection/drainage layer, extended under the window mullion (fenestration assembly) and carried to the inside edge of the curb. Membrane gussets must be installed at all corners and transitions.&lt;br /&gt;
;(3) [[SBS Roof Systems Standard#PART_11|'''Protection/Drainage Layer''']] '''- Insulation Surfacing''': Assemblies to be determined by Design Authority. Paver systems are required to have proprietary pedestals that incorporate a minimum 3mm (1/8&amp;quot;) gap between adjacent units.   See additional requirements under [[SBS Roof Systems Standard#PART_12|'''12.1 Protected and Modified Protected Membrane Roof Assemblies''']].&lt;br /&gt;
;(4) [[SBS Roof Systems Standard#PART_13|'''Metal Wall Flashing''']]: Required on roof assemblies using gravel ballast, filter mats and drainage mediums at insulation /curb interfaces.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;hr&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=== WORK BY OTHERS ===&lt;br /&gt;
;(A) [[SBS Roof Systems Standard#PART_2|'''Acceptable Supporting Deck Structure''']]: Concrete slab shown &lt;br /&gt;
;(B) [[SBS Roof Systems Standard#PART_11|'''Supporting Curb''']]: Height varies depending on the insulation thickness and type of roof assembly.&lt;br /&gt;
;(C) '''Metal Water Stop Flashing''': Mechanically attached to the top of the window curb. Cut flashing to fit the opening and pan fold, weld, or solder seams at all corners and mitres.&lt;br /&gt;
;(D) '''Metal Water Stop Flashing Seam''': Overlap metal water stop joints a minimum of 150mm (6&amp;quot;) and seal joints with two rows of structural sealant.&lt;br /&gt;
;(E) '''Building Envelope Membrane Flashing''': Must be compatible with and overlap the roof membrane flashing. Membrane gussets must be installed at all corners and transitions.&lt;br /&gt;
;(F) [[SBS Roof Systems Standard#PART_13|'''Metal Cap Flashing''']]: Adhere metal cap flashing to membrane flashing with a membrane compatible structural sealant. Mechanical attachment of metal flashing through the membrane flashing is not acceptable.&lt;br /&gt;
;(G) '''Fenestration Assembly''': CAUTION -  Securement fasteners &amp;lt;b&amp;gt;MUST NOT&amp;lt;/b&amp;gt; penetrate the metal or membrane flashing.&lt;br /&gt;
;(H)  '''Fenestration Assembly Securement Bar''': Fasten securement bar ONLY through upper vertical leg of the window mullion (frame).&lt;br /&gt;
&amp;lt;/div&amp;gt;&amp;lt;!-- COL-6-MD --&amp;gt;&lt;br /&gt;
&amp;lt;/div&amp;gt;&amp;lt;!-- PANEL BODY --&amp;gt;&lt;br /&gt;
&amp;lt;/div&amp;gt;&amp;lt;!-- PANEL --&amp;gt;&lt;br /&gt;
&lt;br /&gt;
'''NOTE''': See the [[SBS Roof Systems Standard | '''Standard''']] for additional requirements.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;hr&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[SBS Roof System Details|&amp;lt;i class=&amp;quot;fa fa-chevron-circle-left fa&amp;quot; &amp;gt;&amp;lt;/i&amp;gt; Back to ''&amp;quot;SBS&amp;quot; Roof System Details'']]&lt;br /&gt;
&lt;br /&gt;
[[Main Page | &amp;lt;i class=&amp;quot;fa fa-home fa&amp;quot;&amp;gt;&amp;lt;/i&amp;gt; Home]]&lt;br /&gt;
&lt;br /&gt;
{{Tempate:RPM Page Footer with Copyright and Current Date}}&lt;/div&gt;</summary>
		<author><name>James Klassen</name></author>
		
	</entry>
</feed>