Difference between revisions of "Template:AARS (SBS)"
Difference between revisions of "Template:AARS (SBS)"
Line 394: | Line 394: | ||
| style="vertical-align:center;text-align:center;" | <b> -60 </b> | | style="vertical-align:center;text-align:center;" | <b> -60 </b> | ||
| <html><!-- Single button --><div class="btn-group"><button type="button" class="btn btn-warning dropdown-toggle" data-toggle="dropdown" aria-haspopup="true" aria-expanded="false">View summary<span class="caret"></span></button><ul class="dropdown-menu"> <li><a href="#"><b>Cap membrane</b>: torch-applied</a></li><li><a href="#"><b>Base membrane</b>: N/A (See Insulation Overlay)</a></li><li><a href="#"><b>Insulation overlay</b>: N/A</a></li><li><a href="#"><b>Insulation (top layer)</b>: adhered</a></li></li><li><a href="#"><b>Insulation (bottom layer)</b>: N/A</a></li><li><a href="#"><b>Air/Vapour control layer</b>: self-adhered</a></li><li><a href="#"><b>Deck overlay (thermal barrier)</b>: N/A</a></li><li><a href="#"><b>Roof deck</b></a></li> </ul></div></html> | | <html><!-- Single button --><div class="btn-group"><button type="button" class="btn btn-warning dropdown-toggle" data-toggle="dropdown" aria-haspopup="true" aria-expanded="false">View summary<span class="caret"></span></button><ul class="dropdown-menu"> <li><a href="#"><b>Cap membrane</b>: torch-applied</a></li><li><a href="#"><b>Base membrane</b>: N/A (See Insulation Overlay)</a></li><li><a href="#"><b>Insulation overlay</b>: N/A</a></li><li><a href="#"><b>Insulation (top layer)</b>: adhered</a></li></li><li><a href="#"><b>Insulation (bottom layer)</b>: N/A</a></li><li><a href="#"><b>Air/Vapour control layer</b>: self-adhered</a></li><li><a href="#"><b>Deck overlay (thermal barrier)</b>: N/A</a></li><li><a href="#"><b>Roof deck</b></a></li> </ul></div></html> | ||
− | | style="vertical-align:center;text-align:center;" | [http://rpm.rcabc.org/images/ | + | | style="vertical-align:center;text-align:center;" | [http://rpm.rcabc.org/images/a/a2/SOP-AARS3.pdf '''SOP AARS 3-A'''] |
| style="vertical-align:center;text-align:center;" | <b> 5, 10 </b> | | style="vertical-align:center;text-align:center;" | <b> 5, 10 </b> | ||
| <html><!-- Single button --><div class="btn-group"><button type="button" class="btn btn-success dropdown-toggle" data-toggle="dropdown" aria-haspopup="true" aria-expanded="false">View options <span class="caret"></span></button><ul class="dropdown-menu"> <li><a href="#">Sopralene Flam 250 GR</a></li> </ul></div></html> | | <html><!-- Single button --><div class="btn-group"><button type="button" class="btn btn-success dropdown-toggle" data-toggle="dropdown" aria-haspopup="true" aria-expanded="false">View options <span class="caret"></span></button><ul class="dropdown-menu"> <li><a href="#">Sopralene Flam 250 GR</a></li> </ul></div></html> |
Revision as of 19:35, 1 March 2021
Tested Assembly Report Data | RoofStar Guarantee |
Primary Materials | Other System Materials & Deck | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Manufacturer | Dynamic Uplift Resistance | Roof Assembly Summary |
Test Report | Term† | Cap Membrane |
Base Membrane |
Plies | Insulation Overlay |
Insulation | Deck Overlay |
Deck Type | |
kPa | Psf |