Difference between revisions of "ASM Curb (Split Panel Flashing)"

Jump to: navigation, search

Difference between revisions of "ASM Curb (Split Panel Flashing)"

(No difference)

Revision as of 22:11, 24 April 2019

RoofStar Guarantee Standards are blue-linked
ASM Details

ASM 11.2.1 Curb, Split Panel.jpg

1 WORK INCLUDED

(1) Underlayment
The type of underlay required is determined by roof slope.
(2) Slip Sheet
Recommended over asphaltic underlays and / or as required by metal roof panel manufacturer.
(3) Metal Panel Clip
Installed to metal roof panel manufacturer's printed instructions.
(4) Architectural Metal Roof Panel
(5) Metal Curb Flashing
(6) Cricket
Required for curbs more than 900 mm (36") wide
(7) Acceptable Caulking
Two rows accepted caulking between overlapping sheets, with preformed closures on trapezoidal ribbed roof panels.
(8) Metal Counter Flashing

2 RELATED WORK BY OTHERS

(A) Acceptable Deck
(B) Wood Curb
200 mm (8") minimum height

NOTE: Refer to RoofStar Guarantee Standards for additional requirements.



RoofStar Guarantee Standards for ASM Roof Assemblies

Back to ASM Construction Details

Back to Construction Details