Difference between revisions of "Asphalt Shingles - Changes in Slope (Inside Angle)"

Jump to: navigation, search

Difference between revisions of "Asphalt Shingles - Changes in Slope (Inside Angle)"

(WORK INCLUDED)
(6 intermediate revisions by the same user not shown)
Line 7: Line 7:
 
<div class="col-md-6">
 
<div class="col-md-6">
 
<div style="text-align:center; vertical-align:center">
 
<div style="text-align:center; vertical-align:center">
<big>Applicable to slopes 1:6 (2" in 12") and greater.</big>
 
  
[[File:ASh 9.1.3 CD.jpg|class=img-responsive]]
+
[[File:ASh 9.1.3 CD.jpg|class=img-responsive | link=http://rpm.rcabc.org/images/5/58/ASh_9.1.3_CD.jpg]]
 
</div>
 
</div>
 
</div><!-- COL-MD-6 -->
 
</div><!-- COL-MD-6 -->
Line 18: Line 17:
 
;(2) [[RoofStar Guarantee Standards for Asphalt Shingle Systems#AShEAVES|'''Self-adhered (eave protection) Membrane''']]: Required for this slope change configuration, to seal the upper edge of the metal transition flashing.  When installed, the SA membrane must overlap the metal by at least 50 mm (2”) and extend upslope past the edge of the lower slope underlayment by at least 50 mm (2”).
 
;(2) [[RoofStar Guarantee Standards for Asphalt Shingle Systems#AShEAVES|'''Self-adhered (eave protection) Membrane''']]: Required for this slope change configuration, to seal the upper edge of the metal transition flashing.  When installed, the SA membrane must overlap the metal by at least 50 mm (2”) and extend upslope past the edge of the lower slope underlayment by at least 50 mm (2”).
 
;(3) [[RoofStar Guarantee Standards for Asphalt Shingle Systems#AShTRANSITIONS|'''Metal Transition Flashing''']]: The lower leg must measure at least 100 mm (4”); the upper leg should measure at least 125 mm (5”).
 
;(3) [[RoofStar Guarantee Standards for Asphalt Shingle Systems#AShTRANSITIONS|'''Metal Transition Flashing''']]: The lower leg must measure at least 100 mm (4”); the upper leg should measure at least 125 mm (5”).
;(4) [[RoofStar Guarantee Standards for Asphalt Shingle Systems#AShFIELDAPPLICATION|'''Starter Shingle''']]:  
+
;(4) '''Clip''': Optional.
;(5) [[RoofStar Guarantee Standards for Asphalt Shingle Systems#AShFIELDAPPLICATION|'''Shingle''']]:  
+
;(5) [[RoofStar Guarantee Standards for Asphalt Shingle Systems#AShFIELDAPPLICATION|'''Starter Shingle''']]:  
 +
;(6) [[RoofStar Guarantee Standards for Asphalt Shingle Systems#AShFIELDAPPLICATION|'''Shingle''']]:
  
 
<hr>
 
<hr>
Line 36: Line 36:
 
[[RoofStar Guarantee Standards for Asphalt Shingle Systems|<i class="fa fa-chevron-circle-left fa" ></i> RoofStar Guarantee Standards for Asphalt Shingle Systems]]
 
[[RoofStar Guarantee Standards for Asphalt Shingle Systems|<i class="fa fa-chevron-circle-left fa" ></i> RoofStar Guarantee Standards for Asphalt Shingle Systems]]
  
[[Asphalt Shingles Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Asphalt Shingles Construction Details'']]
+
[[Asphalt Shingle Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Asphalt Shingles Construction Details'']]
  
 
[[Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Construction Details'']]
 
[[Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Construction Details'']]

Revision as of 22:45, 23 October 2019

RoofStar Guarantee Standards are blue-linked
Asphalt Shingle Details

ASh Slope Change - Inside Angle.jpg

1 WORK INCLUDED

(1) Underlayment
Underlayment on the upper slope must overlap the metal transition flashing and lower slope underlayment.
(2) Self-adhered (eave protection) Membrane
Required for this slope change configuration, to seal the upper edge of the metal transition flashing. When installed, the SA membrane must overlap the metal by at least 50 mm (2”) and extend upslope past the edge of the lower slope underlayment by at least 50 mm (2”).
(3) Metal Transition Flashing
The lower leg must measure at least 100 mm (4”); the upper leg should measure at least 125 mm (5”).
(4) Clip
Optional.
(5) Starter Shingle
(6) Shingle

2 RELATED WORK BY OTHERS

(A) Acceptable Deck

NOTE: Refer to RoofStar Guarantee Standards for additional requirements.



RoofStar Guarantee Standards for Asphalt Shingle Systems

Back to Asphalt Shingles Construction Details

Back to Construction Details