TS Details:E4.7.1 (Tile - Hips & Ridges)

Jump to: navigation, search

TS Details:E4.7.1 (Tile - Hips & Ridges)

Revision as of 21:07, 7 September 2021 by James Klassen (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)



Division D - Construction Details


TS Details:E4.7.1 (Tile - Hips & Ridges)

Notice to Reader
Images used in a Construction Detail are representative and not prescriptive. Nor are they necessarily drawn to scale. Rather, they are provided to visually convey the requirements of the Standard they represent. Unless otherwise required by the Standard, dimensions, the selection of materials and their application remains the responsibility of the Design Authority.

The full text of the referenced requirements in the Standard may be read by using the blue hyperlinks
Tile Roofing Details

7.3.2.2.12.jpg

7.3.2.2.13.jpg

1 WORK INCLUDED

(1) Ridge and hip tiles
Ridge and hip tiles are applied after the field tiles are terminated against the nailer board.
(2) Sealant
A sealant, mortar or plaster cement should be applied to the tops of the field tile and between laps of the ridge / hip tile. This prevents entry of wind driven rain or snow.
(3) Tiles
Tiles are started at the low end of hips or the leeward end of ridges. Each tile is nailed through the hole provided into the nailer. The lap of the next tile covers the nail. The last ridge tile nails will have to be caulked.

NOTE: See the Standard for additional requirements.


Back to Tile System Details

Home

© RCABC 2024
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.