Difference between revisions of "Template:Materials - Eave Protection & Underlayment (ASM)"

Jump to: navigation, search

Difference between revisions of "Template:Materials - Eave Protection & Underlayment (ASM)"

Line 41: Line 41:
 
|| '''[[GAF]]''' || [[Materials:Stormguard|Stormguard]] || SBS Modified Bituminous || style="text-align:center;"| Not Stated || style="text-align:center;"| <i class="fa fa-times"></i> || style="text-align:center;"| <i class="fa fa-check"></i> || style="text-align:center;"| <i class="fa fa-check"></i> || style="text-align:center;"| 1.02 (40) || style="text-align:center;"| Self-adhering || style="text-align:center;"| Can be left exposed for up to 60 days
 
|| '''[[GAF]]''' || [[Materials:Stormguard|Stormguard]] || SBS Modified Bituminous || style="text-align:center;"| Not Stated || style="text-align:center;"| <i class="fa fa-times"></i> || style="text-align:center;"| <i class="fa fa-check"></i> || style="text-align:center;"| <i class="fa fa-check"></i> || style="text-align:center;"| 1.02 (40) || style="text-align:center;"| Self-adhering || style="text-align:center;"| Can be left exposed for up to 60 days
 
|-
 
|-
|| '''[[HAL Industries Inc.]]'''|| [[Materials:“Super” Tilemate G100 FW|“Super” Tilemate G100 FW]] || SBS Modified Bituminous || style="text-align:center;"| Woven Polypropylene || style="text-align:center;"| <i class="fa fa-check"></i> || style="text-align:center;"| <i class="fa fa-check"></i> || style="text-align:center;"| <i class="fa fa-check"></i> || style="text-align:center;"| 1.00 (40) || style="text-align:center;"| Self-adhering || style="text-align:center;"| ‒
+
|| '''[[HAL Industries Inc.]]''' || [[Materials:“Super” Tilemate G100 FW|“Super” Tilemate G100 FW]] || SBS Modified Bituminous || style="text-align:center;"| Woven Polypropylene || style="text-align:center;"| <i class="fa fa-check"></i> || style="text-align:center;"| <i class="fa fa-check"></i> || style="text-align:center;"| <i class="fa fa-check"></i> || style="text-align:center;"| 1.00 (40) || style="text-align:center;"| Self-adhering || style="text-align:center;"| ‒
 
|-
 
|-
 
|| '''[[Henry Company Canada]]''' || [[Materials:Blueskin PE 200 HT|Blueskin PE 200 HT]] || SBS Modified Bituminous || style="text-align:center;"| Blue-Cross Laminated Polyethylene || style="text-align:center;"| <i class="fa fa-check"></i> || style="text-align:center;"| <i class="fa fa-check"></i> || style="text-align:center;"| <i class="fa fa-check"></i> || style="text-align:center;"| 1.00 (40) || style="text-align:center;"| Self-adhering || style="text-align:center;"| ‒
 
|| '''[[Henry Company Canada]]''' || [[Materials:Blueskin PE 200 HT|Blueskin PE 200 HT]] || SBS Modified Bituminous || style="text-align:center;"| Blue-Cross Laminated Polyethylene || style="text-align:center;"| <i class="fa fa-check"></i> || style="text-align:center;"| <i class="fa fa-check"></i> || style="text-align:center;"| <i class="fa fa-check"></i> || style="text-align:center;"| 1.00 (40) || style="text-align:center;"| Self-adhering || style="text-align:center;"| ‒
Line 64: Line 64:
 
|-
 
|-
 
|| '''[[Owens Corning Canada]]''' || [[Materials:RhinoRoof U20 |RhinoRoof U20]] ||   Multi-layer polymer-coated woven synthetic underlayment || style="text-align:center;"| Not Stated || style="text-align:center;"| <i class="fa fa-times"></i> || style="text-align:center;"| <i class="fa fa-times"></i> || style="text-align:center;"| <i class="fa fa-check"></i> || style="text-align:center;"| 0.18 (7) || style="text-align:center;"| Nail-applied || style="text-align:center;"|   Underlayment Only for roofs 4:12 or greater  
 
|| '''[[Owens Corning Canada]]''' || [[Materials:RhinoRoof U20 |RhinoRoof U20]] ||   Multi-layer polymer-coated woven synthetic underlayment || style="text-align:center;"| Not Stated || style="text-align:center;"| <i class="fa fa-times"></i> || style="text-align:center;"| <i class="fa fa-times"></i> || style="text-align:center;"| <i class="fa fa-check"></i> || style="text-align:center;"| 0.18 (7) || style="text-align:center;"| Nail-applied || style="text-align:center;"|   Underlayment Only for roofs 4:12 or greater  
 +
|-
 +
|| '''[[Polyglass USA, Inc.]]''' || [[Materials:Polystick MTS|Polystick MTS]] || Proprietary Compound || style="text-align:center;"| fibreglass mat || style="text-align:center;"| <i class="fa fa-times"></i> || style="text-align:center;"| <i class="fa fa-check"></i> || style="text-align:center;"| <i class="fa fa-check"></i> || style="text-align:center;"| 1.50 (60) || style="text-align:center;"| Self-adhering || style="text-align:center;"| ‒
 
|-
 
|-
 
|| '''[[Protecto Wrap Company]]''' || [[Materials:Jiffy Seal Ice and Water Guard HT|Jiffy Seal Ice and Water Guard HT]] || SBS Modified Bituminous || style="text-align:center;"| tri-layer woven polyolefin || style="text-align:center;"| <i class="fa fa-check"></i> || style="text-align:center;"| <i class="fa fa-check"></i> || style="text-align:center;"| <i class="fa fa-check"></i> || style="text-align:center;"| 1.00 (40) || style="text-align:center;"| Self-adhering || style="text-align:center;"| ‒
 
|| '''[[Protecto Wrap Company]]''' || [[Materials:Jiffy Seal Ice and Water Guard HT|Jiffy Seal Ice and Water Guard HT]] || SBS Modified Bituminous || style="text-align:center;"| tri-layer woven polyolefin || style="text-align:center;"| <i class="fa fa-check"></i> || style="text-align:center;"| <i class="fa fa-check"></i> || style="text-align:center;"| <i class="fa fa-check"></i> || style="text-align:center;"| 1.00 (40) || style="text-align:center;"| Self-adhering || style="text-align:center;"| ‒

Revision as of 21:40, 26 February 2018

The problems resulting from the presence of condensation represent one of the major causes of damage to the structure and fabric of old and modern buildings alike. They are, therefore, of great importance to the specifier in his design role. The increased use of insulation and modern roof construction methods have created further major condensation risks within the roof void.

The specifier must ensure that the risk of condensation is minimised by ensuring the correct design, suitable ventilation in accordance with the B.C. Building Code, and specification of the most suitable underlay.

RoofStar-guaranteed metal roofing systems require a suitable underlay to ensure that any moisture produced by condensation is not introduced into the roofing system components or the structure of the building. Modified bituminous membranes that are not arranged under insulation must have a high softening point bitumen with a minimum flow temperature of 87.7°C (190°F) to prevent material displacement from heat transfer through metal panels during high temperature days. (See UNDERLAYMENT - Eave and Detail Protection (ASM Roof Systems)). All accepted modified bituminous self-adhesive membranes listed exceed a minimum flow temperature of 87.7°C (190°F.).

Accepted No. 30 Asphalt felt or RoofStar-accepted proprietary synthetic underlayments that meet or exceed the CSA A123.3 standards for No. 30 Asphalt Felt are acceptable for use on uninsulated wood decks sloped over 4" in 12". Manufacturer's limitations are to be followed.

For RoofStar-accepted No. 30 asphalt felts refer to BUR Felts in the Accepted Materials section of this Manual.

Click on a manufacturer's name to see the full list of their products accepted for use in the RoofStar Guarantee Program
Manufacturer Product Name Product Type Top Surface Use as Slip Sheet Eaves & Valleys Under -layment Nominal Thickness - mm (mil) Application Method Special Notes
No. 30 Asphalt Felt Various Felt underlayment Non-woven Felt Variable Nail-applied For uninsulated wood decks only with slopes of 1:3 (4" in 12") or greater
Building Products of Canada Corp. Gripgard SBS Modified Bituminous Sanded 1.00 (40) Self-adhering
CertainTeed Corporation DiamondDeck Reinforced synthetic Synthetic Polymer N/A Nail-applied
Firestone Building Products Clad-Gard SA SBS Modified Bituminous Woven Polyethylene 1.00 (40) Self-adhering Can be left exposed for up to 90 days
Firestone Building Products Clad-Gard MA SBS Modified Bituminous Not Stated N/A Self-adhering Synthetic underlayment only for slopes greater than 5:12 / can be left exposed for up to 90 days
FT Synthetics FT Synthetics PLATINUM Water-resistant Polyolefin Polyolefin 0.50 (20) Nail-applied Underlayment Only for roofs 4:12 or greater
FT Synthetics FT Synthetics GOLD Water-resistant Polyolefin Polyolefin 0.40 (16) Nail-applied Underlayment Only for roofs 4:12 or greater
FT Synthetics FT Synthetics SILVER Water-resistant Polyolefin Polyolefin 0.30 (12) Nail-applied
FT Synthetics FT Synthetics PLATINUM HT-SA Water-resistant Polyolefin GRIPSPOT TM 1.04 (41) Self-adhering
GAF Stormguard SBS Modified Bituminous Not Stated 1.02 (40) Self-adhering Can be left exposed for up to 60 days
HAL Industries Inc. “Super” Tilemate G100 FW SBS Modified Bituminous Woven Polypropylene 1.00 (40) Self-adhering
Henry Company Canada Blueskin PE 200 HT SBS Modified Bituminous Blue-Cross Laminated Polyethylene 1.00 (40) Self-adhering
Henry Company Canada Blueskin RF 200 SBS Modified Bituminous Slip-resistant Film 1.00 (40) Self-adhering
Henry Company Canada Eaveguard SBS Modified Bituminous Sanded 1.30 (50) Self-adhering
IKO Industries Ltd. Armourgard Ice & Water Protector SBS Modified Bituminous Sanded 1.80 (71) Self-adhering
Malarkey Roofing Products Right Start™ UDL SBS Modified Bituminous Sanded 1.40 (55) Nail-applied For uninsulated wood decks only with slopes of 1:3 (4" in 12") or greater
Malarkey Roofing Products Arctic Seal Ice & Water Guard SBS Modified Bituminous Sanded 1.52 (60) Self-adhering
Owens Corning Canada Titanium UDL 25 Polypropylene Synthetic Synthetic (not stated) 0.38 (15) Nail-applied
Owens Corning Canada Titanium UDL 30 Polypropylene Synthetic Synthetic (not stated) 0.63 (25) Nail-applied
Owens Corning Canada Titanium UDL 50 Polypropylene Synthetic Synthetic (not stated) 0.75 (30) Nail-applied
Owens Corning Canada Titanium PSU 30 SBS Modified Bituminous Synthetic Polymer 1.10 (45) Self-adhering
Owens Corning Canada RhinoRoof U20 Multi-layer polymer-coated woven synthetic underlayment Not Stated 0.18 (7) Nail-applied Underlayment Only for roofs 4:12 or greater
Polyglass USA, Inc. Polystick MTS Proprietary Compound fibreglass mat 1.50 (60) Self-adhering
Protecto Wrap Company Jiffy Seal Ice and Water Guard HT SBS Modified Bituminous tri-layer woven polyolefin 1.00 (40) Self-adhering
Protecto Wrap Company Jiffy Seal Butyl Ice and Water Guard HT SBS Modified Bituminous tri-layer woven polyolefin 0.75 (30) Self-adhering
Soprema Inc. Lastobond 195 SBS Modified Bituminous Sanded 1.60 (63) Self-adhering
Soprema Inc. Lastobond 240 SBS Modified Bituminous Sanded 1.60 (63) Self-adhering
Soprema Inc. Lastobond Shield SBS Modified Bituminous tri-laminate woven polyethylene 1.00 (40) Self-adhering
Soprema Inc. Lastobond Shield HT SBS Modified Bituminous tri-laminate woven polyethylene 1.00 (40) Self-adhering
Soprema Inc. Sopraseal Stick 1100 T SBS Modified Bituminous tri-laminate woven polyethylene 1.00 (40) Self-adhering