==General==
 
==General==
 
<ol>
 
<ol>
<li>This Part covers the design and installation requirements for roofs that support an ''Overburden'', whether it is structurally supported or non-structurally situated on the roof platform.  These ''Overburdens'' include
+
<li>This Part covers the design and installation requirements for roofs that support an ''overburden'', whether it is structurally supported or non-structurally situated on the roof platform.  ''Overburdens'' include
 
<ol>
 
<ol>
 
<li><u>''Roof Coverings''</u> (including, without limitation)
 
<li><u>''Roof Coverings''</u> (including, without limitation)
 
<ol>
 
<ol>
<li>gravel ballast.
+
<li>gravel.
 
<li>wearing surfaces and living spaces (rooftop terraces) – pavers, wood or composite decks and walkways, cast-in-place concrete, rubberized surfaces and playscapes, pet relief areas.
 
<li>wearing surfaces and living spaces (rooftop terraces) – pavers, wood or composite decks and walkways, cast-in-place concrete, rubberized surfaces and playscapes, pet relief areas.
 
<li>gardens/vegetated assemblies (modular and built-in-place).
 
<li>gardens/vegetated assemblies (modular and built-in-place).
Line 22: Line 22:
 
</li></ol>
 
</li></ol>
 
<li>Any ''roof covering'', structure or item of equipment must be installed in a manner that protects the roof membrane and its performance.
 
<li>Any ''roof covering'', structure or item of equipment must be installed in a manner that protects the roof membrane and its performance.
<li>Coverage under the '''''RoofStar Guarantee''''' may be affected by ''roof coverings'' or equipment that impede access to the roof assembly.  Refer to '''Part 1 General''' in this ''Standard''.
+
<li>Coverage under the '''''RoofStar Guarantee''''' may be affected by ''roof coverings'' or equipment that impede access to the ''roof system''.  Refer to '''Part 1 General''' in this ''Standard''.
 
</li></ol>
 
</li></ol>
 
</li></ol>
 
</li></ol>
Line 28: Line 28:
 
===Definitions===
 
===Definitions===
 
Refer to the [http://rpm.rcabc.org/index.php?title=Glossary '''Glossary'''] for further definitions of key terms used in this ''Manual''.
 
Refer to the [http://rpm.rcabc.org/index.php?title=Glossary '''Glossary'''] for further definitions of key terms used in this ''Manual''.
:;''Extensive Vegetated Roof Systems'': sometimes referred to as 'eco-roofs', 'low-profile green roofs,' ' rooftop gardens' or simply as 'green roofs'
+
:;''Extensive Vegetated Roof Systems'': sometimes referred to as "eco-roofs", 'low-profile green roofs," "rooftop gardens" or simply as "green roofs"
 
:#are installed and maintained without the use of penetrating hand tools.
 
:#are installed and maintained without the use of penetrating hand tools.
 
:#utilize pre-assembled trays, boxes, mats or other contained soil or media.
 
:#utilize pre-assembled trays, boxes, mats or other contained soil or media.
Line 36: Line 36:
 
:#are not normally accessed by building occupants.
 
:#are not normally accessed by building occupants.
 
:;
 
:;
:;''Inaccessible Overburden'': means an ''Overburden'' that must be demolished in order to access the roof membrane.  A concrete split slab is a type of inaccessible ''Overburden''.
+
:;''Inaccessible Overburden'': means an ''overburden'' that must be demolished in order to access the roof membrane.  A concrete split slab is a type of inaccessible ''overburden''.
 
:;
 
:;
:;''Overburden'': (also referred to as a wearing course or layer) means a ''roof covering'', structure or item of equipment that is situated on top of, and covering all or a portion of, a constructed ''Waterproofing System''. ''Overburden'' includes, without limitation,
+
:;''Overburden'': (also referred to as a wearing course or layer) means a ''roof covering'', structure or item of equipment that is situated on top of, and covering all or a portion of, a constructed ''waterproofing system''. ''Overburden'' includes, without limitation,
  
 
::<u>''Roof Coverings''</u>
 
::<u>''Roof Coverings''</u>
Line 60: Line 60:
 
:#signage and lighting.
 
:#signage and lighting.
 
:;
 
:;
:;''Roof Platform'': means a ''roof assembly'' which supports an ''Overburden'' or living (amenity) space consisting of ''coverings'', structures or equipment that are not part of the ''assembly''.
+
:;''Roof Platform'': means a ''roof assembly'' which supports an ''overburden'' or living (amenity) space consisting of ''coverings'', structures or equipment that are not part of the ''assembly''.
 
;:
 
;:
 
+
<div id="PLAT_DESIGN"></div>
 
===Design===
 
===Design===
 
<span class="reference">Membrane ''roof systems'' may be utilized for more than simple weather protection; they can be occupied by casual or regular users, for gardening, playing, lounging, or other leisure activities.  Roofs that serve as amenity spaces require that the ''Design Authority'' pay particular attention to the ''system'' selection itself and, especially, to the protection of the roof membrane</span>.
 
<span class="reference">Membrane ''roof systems'' may be utilized for more than simple weather protection; they can be occupied by casual or regular users, for gardening, playing, lounging, or other leisure activities.  Roofs that serve as amenity spaces require that the ''Design Authority'' pay particular attention to the ''system'' selection itself and, especially, to the protection of the roof membrane</span>.
Line 68: Line 68:
 
<span class="reference">A ''Conventionally Insulated System'' is not appropriate for all types of use or ''roof coverings''. For example, the designed live loading for occupied spaces, or the weight of a ''roof covering'', may require the ''Design Authority'' to specify particular materials, and consequently to design a roof as a ''Protected Membrane Roof System''.  Furthermore, some ''roof coverings'' require maintenance that may result in damage to ''Conventionally Insulated Systems''; ''Protected Membrane Roof Systems'' shield the sensitive membrane from this inevitability</span>.
 
<span class="reference">A ''Conventionally Insulated System'' is not appropriate for all types of use or ''roof coverings''. For example, the designed live loading for occupied spaces, or the weight of a ''roof covering'', may require the ''Design Authority'' to specify particular materials, and consequently to design a roof as a ''Protected Membrane Roof System''.  Furthermore, some ''roof coverings'' require maintenance that may result in damage to ''Conventionally Insulated Systems''; ''Protected Membrane Roof Systems'' shield the sensitive membrane from this inevitability</span>.
  
<span class="reference">A ''Protected Membrane Roof Assembly'' (often referred to as an ‘inverted roof’) offers the designer many benefits, including</span>
+
<span class="reference">A ''Protected Membrane Roof System'' (often referred to as an "inverted roof") offers the designer many benefits, including</span>
 
*<span class="reference">longer lasting membranes</span>.
 
*<span class="reference">longer lasting membranes</span>.
 
*<span class="reference">capacity for heavier dead and live loads</span>.
 
*<span class="reference">capacity for heavier dead and live loads</span>.
Line 79: Line 79:
 
Criteria for evaluating the sensitivity of building interiors is left to the ''Design Authority''.
 
Criteria for evaluating the sensitivity of building interiors is left to the ''Design Authority''.
  
This Subsection is written to provide guidance by way of general Standards and Guiding Principles, to assist the ''Design Authority'' in making the best possible choices for the ''roof assembly''.
+
This Subsection is written to provide guidance by way of general standards and guiding principles, to assist the ''Design Authority'' in making the best possible choices for the ''roof assembly''.
  
 
====<big>General</big>====
 
====<big>General</big>====
 
<ol>
 
<ol>
<li>The building structure must be designed to support any live loads required under the Building Code having jurisdiction, together with the loads from any covering, amenity space, structure or live loads superimposed upon the roof platform.
+
<li>The building structure must be designed to support any live loads specified by the Code having jurisdiction.  This includes loads from any covering, amenity space, structure or live loads superimposed upon the roof platform.
 
<li><span class="principles">The ''Design Authority'' should give thought to the inevitability of roof repairs or replacement when designing the coverings, living spaces or structures the roof will support.  This includes, without limitation,</span>
 
<li><span class="principles">The ''Design Authority'' should give thought to the inevitability of roof repairs or replacement when designing the coverings, living spaces or structures the roof will support.  This includes, without limitation,</span>
 
<ol>
 
<ol>
Line 99: Line 99:
 
<li><span class="recommended">includes expansive terrace areas or play spaces</span>.
 
<li><span class="recommended">includes expansive terrace areas or play spaces</span>.
 
</li></ol>
 
</li></ol>
<li>Roofs designed as platforms for ''coverings'', amenity spaces and equipment must take into account the following Standards and Guiding Principles:
+
<li>Roofs designed as platforms for ''coverings'', amenity spaces and equipment must take into account the following standards and guiding principles:
 
<ol>
 
<ol>
 
<li>'''Load bearing''':  
 
<li>'''Load bearing''':  
 
<ol>
 
<ol>
<li>'''Non-structural installations''' - Insulation and ''insulation overlays'' used in a ''Conventionally Insulated System'' or ''Modified Protected Membrane Roof System'' must have a minimum load carrying capacity of 110 Kpa (20 psi), but in any event must be capable of supporting any superimposed loads on the exposed membrane, without compression or distortion of the ''roof system'' or any one of its components.  Otherwise, the roof platform must be designed as a ''Protected Membrane Roof System''.  See also '''8.1.1 Design (Insulation Overlays)'''.
+
<li>'''Non-structural installations''': Insulation and ''insulation overlays'' used in a ''Conventionally Insulated System'' or ''Modified Protected Membrane Roof System'' must have a minimum load carrying capacity of 110 Kpa (20 psi), but in any event must be capable of supporting any superimposed loads on the exposed membrane, without compression or distortion of the ''roof system'' or any one of its components.  Otherwise, the roof platform must be designed as a ''Protected Membrane Roof System''.  See also '''8.1.1 Design (Insulation Overlays)'''.
 
<li>'''Structural installations''' - <span class="principles">structural supports (i.e. curbs) should be considered to bear heavier dead loads, to resist ''Specified Wind Loads'', or to secure the equipment during seismic events</span>.
 
<li>'''Structural installations''' - <span class="principles">structural supports (i.e. curbs) should be considered to bear heavier dead loads, to resist ''Specified Wind Loads'', or to secure the equipment during seismic events</span>.
 
</li></ol>
 
</li></ol>
<li>Membrane thickness and puncture resistance: Membranes must be selected for their ability to resist accidental puncture by human activity on the roof; the minimum puncture resistance must be at least 400 N.  Refer to the table in '''9.1.2''' for minimum membrane thickness and puncture resistance requirements.
+
<li>'''Membrane thickness and puncture resistance''': Membranes must be selected for their ability to resist accidental puncture by human activity on the roof; the minimum puncture resistance must be at least 400 N.  Refer to the table in '''9.1.2''' for minimum membrane thickness and puncture resistance requirements.
 
<li>'''Protection''':
 
<li>'''Protection''':
 
<ol>
 
<ol>
Line 115: Line 115:
 
<li>from maintenance of any installation on top of a ''roof system'', after the building has been commissioned.
 
<li>from maintenance of any installation on top of a ''roof system'', after the building has been commissioned.
 
</li></ol>
 
</li></ol>
<li><span class="recommended">To prevent accidental damage and puncture from falling objects, conventional roofs at elevations lower than those designed for human occupancy should include a protective wearing course or, in the alternative, should be designed as a ''Protected Membrane Roof System''</span>.
+
<li><span class="recommended">To prevent accidental damage and puncture from falling objects, ''Conventional Insulated Systems'' at elevations lower than those designed for human occupancy should include a protective wearing course or, in the alternative, should be designed as a ''Protected Membrane Roof System''</span>.
 
<li>Where membranes installed on vertical surfaces may be damaged from foot traffic or shifting coverings, they must be protected as, for example, with base metal flashings.  See '''13.3.5 Cap, Counter and Base Flashings'''.
 
<li>Where membranes installed on vertical surfaces may be damaged from foot traffic or shifting coverings, they must be protected as, for example, with base metal flashings.  See '''13.3.5 Cap, Counter and Base Flashings'''.
 
<li>Filter fabrics are required for roof platforms supporting
 
<li>Filter fabrics are required for roof platforms supporting
Line 128: Line 128:
 
<li>'''Drainage''':  
 
<li>'''Drainage''':  
 
<ol>
 
<ol>
<li>Roofs designed as platforms to support ''roof coverings'', amenity spaces or equipment must promote unimpeded drainage of storm or irrigation water.  Where a roof covering material naturally drains (gravel, for example), no additional drainage design is required. In all other cases, the design must incorporate a drainage plane above the supporting roof platform.
+
<li>Roofs designed as platforms to support ''roof coverings'', amenity spaces or equipment must promote unimpeded drainage of storm or irrigation water.  Where a ''roof covering'' material naturally drains (gravel, for example), no additional drainage design is required. In all other cases, the design must incorporate a ''drainage plane'' above the supporting roof platform.
 
<li>''Overburden'' must be contained with drain guards, rigid barriers and filter fabric.  See also '''11.2.2 Roof Drains and Scuppers'''.
 
<li>''Overburden'' must be contained with drain guards, rigid barriers and filter fabric.  See also '''11.2.2 Roof Drains and Scuppers'''.
<li>Equipment supports placed on the roof system must not impede the flow of water to drains.  To facilitate the adequate movement of water when supports are oriented perpendicular to drainage flow,
+
<li>Equipment supports placed on the ''roof system'' must not impede the flow of water to drains.  To facilitate the adequate movement of water when supports are oriented perpendicular to drainage flow,
 
<ol>
 
<ol>
 
<li>utilize shorter supports, to a maximum length of 1200 mm (4’).
 
<li>utilize shorter supports, to a maximum length of 1200 mm (4’).
Line 136: Line 136:
 
</li></ol>
 
</li></ol>
 
</li></ol>
 
</li></ol>
<li>'''Clearance and accessibility''': equipment installed on structural supports or on top of the ''roof system'' must be spaced or located in order to promote access to drains, ease of maintenance and worker or occupant safety.
+
<li>'''Clearance and accessibility''': equipment installed on structural supports or on top of the ''roof system'' must be spaced or located to promote access to drains, ease of maintenance and worker or occupant safety.
<li>'''An Integrity Scan'''
+
<li>'''An Integrity Scan''': see '''1.6''' ('''7''') ('''1.6 RoofStar Guarantee: Coverage and Limitations''').
<ol>
+
<li>'''Electronic Leak Detection''' is mandatory for grade-level ''waterproofing systems'', but optional for roof ''Waterproofing Systems''.
<li>must be performed by an RGC-recognized service provider.
 
<li>is required on all ''Waterproofing Systems'', to ensure the waterproofing is leak and damage-free, when ''Overburdens'', amenities or equipment are or will be installed on the completed ''Waterproofing System'' by
 
<ol>
 
<li>anyone other than the ''Contractor''.
 
<li>the ''Contractor'' but only when the ''Overburdens'', amenities or equipment exceed 150 mm (6”) in depth. 
 
</li></ol>
 
<li>is <u>not required</u> when the ''Contractor'' installs overburden, amenities or equipment equal to or less than 150 mm (6”) in depth.
 
</li></ol>
 
<br>
 
An Integrity Scan is <u>not required</u> when the Contractor installs overburden, amenities or equipment equal to or less than 150 mm (6”) in depth.
 
<li>'''Electronic Leak Detection''' is mandatory for grade-level ''Waterproofing Systems'', but optional for ''Waterproofing Systems'' on roofs.
 
 
<br>
 
<br>
 
<br>
 
<br>
Line 162: Line 151:
 
<li>When gravel is specified as the ''roof covering'',
 
<li>When gravel is specified as the ''roof covering'',
 
<ol>
 
<ol>
<lithe design must include gravel guards around roof drains.
+
<li>the design must include gravel guards around roof drains.
 
<li>only washed gravel may be used.
 
<li>only washed gravel may be used.
 
</li></ol>
 
</li></ol>
Line 177: Line 166:
 
<ol>
 
<ol>
 
<li>the compressive strength of the insulation will support it.
 
<li>the compressive strength of the insulation will support it.
<li>the insulation in the roof assembly is overlaid with a suitable insulation overlay (see '''8.3.1.2 (4)''').
+
<li>the insulation in the ''roof assembly'' is overlaid with a suitable insulation overlay (see '''8.3.1.2''' ('''4''')).
 
<li>the wearing surface does not bond with or touch the roof field membrane or membrane flashing.
 
<li>the wearing surface does not bond with or touch the roof field membrane or membrane flashing.
 
<li>drainage of storm or irrigation water is not impeded.
 
<li>drainage of storm or irrigation water is not impeded.
Line 184: Line 173:
 
<ol>
 
<ol>
 
<li>pedestals.
 
<li>pedestals.
vproprietary pads.
+
<li>proprietary pads.
 
<li>XPS insulation.
 
<li>XPS insulation.
 
<li>drainage mats.
 
<li>drainage mats.
 
</li></ol>
 
</li></ol>
<li><span class="principles">Wearing surfaces may be sloped or level, depending upon the intent of the design, and therefore ''Project'' specifications and drawings should indicate this</span>.
+
<li><span class="principles">Wearing surfaces may be sloped or level, depending upon the intent of the design, and therefore ''project'' specifications and drawings should indicate this</span>.
 
<li>When cast-in-place concrete is used as a ''roof covering'' directly over the roof membrane, the concrete must be separated from the membrane with both of the following:
 
<li>When cast-in-place concrete is used as a ''roof covering'' directly over the roof membrane, the concrete must be separated from the membrane with both of the following:
 
<ol>
 
<ol>
Line 198: Line 187:
 
=====<big><u>Vegetated Roof Systems</u></big>=====
 
=====<big><u>Vegetated Roof Systems</u></big>=====
 
<ol>
 
<ol>
<li>Modular ''Vegetated Roof Systems'' (VRS) must be designed to resist the ''Specified Wind Loads'' calculated using the WIND-MVRA online calculator (see also '''Part 3 SECURING the ROOF ASSEMBLY''').  Since ''Vegetated Roof Systems'' often provide ballast for ''Protected Membrane Roof Systems'' and may be installed by someone other than the ''Contractor'', the ''Design Authority'' must specify the coordination of work to ensure the ''roof system'' is immediately and properly secured.
+
<li>''Vegetated Roof Systems'' (VRS) must be designed to resist the ''Specified Wind Loads'' calculated using the WIND-MVRA online calculator (see also '''Part 3 SECURING the ROOF ASSEMBLY''').  Since ''Vegetated Roof Systems'' often provide ballast for ''Protected Membrane Roof Systems'' and may be installed by someone other than the ''Contractor'', the ''Design Authority'' must specify the coordination of work to ensure the ''roof system'' is immediately and properly secured.
 
<li>''Conventionally Insulated Systems'' may be used to support any type of ''Vegetated Roof System'', provided
 
<li>''Conventionally Insulated Systems'' may be used to support any type of ''Vegetated Roof System'', provided
 
<ol>
 
<ol>
 
<li>the compressive strength of the insulation will support it.
 
<li>the compressive strength of the insulation will support it.
<li>the insulation in the roof assembly is overlaid with a suitable insulation overlay (see '''8.3.1.2 (4)''').
+
<li>the insulation in the ''roof system'' is overlaid with a suitable insulation overlay (see '''8.3.1.2''' ('''4''')).
 
<li>the membrane manufacturer is agreeable to the application and is confident the membrane can withstand the anticipated hydrostatic pressures when the ''Vegetated Roof System'' is fully saturated with water.
 
<li>the membrane manufacturer is agreeable to the application and is confident the membrane can withstand the anticipated hydrostatic pressures when the ''Vegetated Roof System'' is fully saturated with water.
 
<li>the membrane is fully adhered.
 
<li>the membrane is fully adhered.
Line 256: Line 245:
 
<li>'''Pre‐curbs''' must be
 
<li>'''Pre‐curbs''' must be
 
<ol>
 
<ol>
<li>at least 100 mm (4") in height above the water plane of the highest adjacent roof assembly.
+
<li>at least 100 mm (4") in height above the ''drainage plane'' of the highest adjacent ''roof assembly''.
 
<li>completely enveloped with fully adhered acceptable membrane flashing (including all faces of drainage knock‐outs).
 
<li>completely enveloped with fully adhered acceptable membrane flashing (including all faces of drainage knock‐outs).
 
<li>properly waterproofed around dowels {{hilite |in their final position with either of the following|| 2021-February-7 }}:
 
<li>properly waterproofed around dowels {{hilite |in their final position with either of the following|| 2021-February-7 }}:
Line 275: Line 264:
 
<li>When a structural planter adjoins a ''Conventionally Insulated System'', only a plumbed mechanical drain is permissible.
 
<li>When a structural planter adjoins a ''Conventionally Insulated System'', only a plumbed mechanical drain is permissible.
 
<li><span class="recommended">A design review is advisable when a structural water features incorporates penetrations for wiring, lights or other submerged features</span>.
 
<li><span class="recommended">A design review is advisable when a structural water features incorporates penetrations for wiring, lights or other submerged features</span>.
<li>Tiles or other architectural finishes may be applied to the waterproofing membrane, subject to a written Variance from the ''Guarantor'' and approval by the membrane manufacturer.
+
<li>Tiles or other architectural finishes may be applied to the waterproofing membrane, subject to a written Variance from the '''''Guarantor''''' and approval by the membrane manufacturer.
 
<li>Drains, re-circulation inlets and outlets used in water features must include clamping rings and must be sealed to the membrane assembly.
 
<li>Drains, re-circulation inlets and outlets used in water features must include clamping rings and must be sealed to the membrane assembly.
 
<li>When a leak detection system is specified, or required, only non‐ferrous metal drains may be used.
 
<li>When a leak detection system is specified, or required, only non‐ferrous metal drains may be used.
 
<li>Drain connections to internal piping must be made with mechanical compression type seals only.
 
<li>Drain connections to internal piping must be made with mechanical compression type seals only.
 
</li></ol>
 
</li></ol>
 +
<div id="PLAT_MATERIALS"></div>
  
 
==Materials==
 
==Materials==
Line 301: Line 291:
 
See also '''Part 7 INSULATION'''
 
See also '''Part 7 INSULATION'''
 
<ol>
 
<ol>
<li>Insulation that supports an acceptable roof covering must have a minimum compressive strength equal to or exceeding the dead loads and anticipated overall live loads and point loads of the overburden.
+
<li>Insulation used in a ''Protected Membrane Roof System'' must be extruded polystyrene foam Insulation (XPS).
<li>Insulation used in a ''Protected Membrane Roof System'' must be Extruded Polystyrene Foam Insulation (XPS).
+
<li>When XPS (with or without a concrete topping) is specified as the drainage layer, it must be grooved (by the manufacturer or as a post-manufacturing alteration).
<li>When XPS (with or without a concrete topping) is specified as the drainage layer, it must be grooved (by the manufacturer or post-manufacturing).
+
<li>Insulation that supports an acceptable ''roof covering'' must have a minimum compressive strength equal to or exceeding the dead loads and anticipated overall live loads and point loads of the ''overburden''.
 
<li>When an insulation overlay is required (see '''14.1.2.2'''), it must be a composite product
 
<li>When an insulation overlay is required (see '''14.1.2.2'''), it must be a composite product
 
<ol>
 
<ol>
<li>no less than 12.7 mm (½") thick.
+
<li>no less than 12.7 mm (1/2") thick.
 
<li>with a minimum compressive strength of 620 kPa (90 psi).
 
<li>with a minimum compressive strength of 620 kPa (90 psi).
 
</li></ol>
 
</li></ol>
Line 325: Line 315:
 
<li>be manufactured with a minimum thickness of 9.5 mm (3/8”).
 
<li>be manufactured with a minimum thickness of 9.5 mm (3/8”).
 
<li>provide a uniform support for ''roof coverings'', structures or equipment installed on the roof platform.
 
<li>provide a uniform support for ''roof coverings'', structures or equipment installed on the roof platform.
<li>have a compressive strength equal to or greater than the design and anticipated live loads of the roof platform and its supported ''coverings'', structures or equipment.
+
<li>have a compressive strength equal to or greater than the design and anticipated live loads of the roof platform and the ''coverings'', structures or equipment it supports.
 
</li></ol>
 
</li></ol>
 
<li>Fabric filter mats must be  
 
<li>Fabric filter mats must be  
Line 335: Line 325:
 
<ol>
 
<ol>
 
<li>must be sheets or boards that are acceptable to the primary roof membrane manufacturer.
 
<li>must be sheets or boards that are acceptable to the primary roof membrane manufacturer.
<li>may be polyethylene or polypropylene sheeting, provided the material is no less than .2mm (8 mils) thick.
+
<li>may be polyethylene or polypropylene sheeting, provided the material is no less than 0.2mm (8 mils) thick.
 
</li></ol>
 
</li></ol>
 
<li>Membrane protection must be either of the following materials:
 
<li>Membrane protection must be either of the following materials:
Line 349: Line 339:
 
<ol>
 
<ol>
 
<li>Decorative gravel (different in function from gravel ballast) must be washed and may be smooth or crushed.
 
<li>Decorative gravel (different in function from gravel ballast) must be washed and may be smooth or crushed.
<li>Large grade gravel may withstand wind scour more effectively than smaller gravel.  The ''Design Authority'' should determine the gradients, based on the ''Specified Wind Loads'' for the roof.  For size options, see '''12.1.2''' ('''6''') for ''Protected Membrane Roof Assemblies''.
+
<li>Large grade gravel may withstand wind scour more effectively than smaller gravel.  The ''Design Authority'' should determine the gradients, based on the ''Specified Wind Loads'' for the roof.  For size options, see '''12.1.2''' ('''6''') for ''Protected Membrane Roof Systems''.
 
</li></ol>
 
</li></ol>
  
Line 358: Line 348:
 
<ol>
 
<ol>
 
<li><span class="principles">should be adjustable, when a level surface is required</span>.
 
<li><span class="principles">should be adjustable, when a level surface is required</span>.
<li>must be proprietary (purpose-made) and include an integral spacer rib measuring at least a 3mm (⅛”), to uniformly separate pavers.
+
<li>must be proprietary (purpose-made) and include an integral spacer rib measuring at least a 3mm (1/8”), to uniformly separate pavers.
 
</li></ol>
 
</li></ol>
 
</li></ol>
 
</li></ol>
 
+
<div id="PLAT_APPLICATION"></div>
 
==Application==
 
==Application==
 
===General===
 
===General===
 
====Membranes====
 
====Membranes====
 
<ol>
 
<ol>
<li>Membranes and membrane flashing must be installed in keeping with the Standards found elsewhere in this ''Manual''.
+
<li>Membranes and membrane flashing must be installed in keeping with the requirements found elsewhere in this Standard.
 
<li>Protection of roof membranes from mechanical damage caused by tools, accident or the work of others is mandatory during the installation and maintenance of any ''roof covering'' or living space.
 
<li>Protection of roof membranes from mechanical damage caused by tools, accident or the work of others is mandatory during the installation and maintenance of any ''roof covering'' or living space.
 
</li></ol>
 
</li></ol>
Line 385: Line 375:
 
<li>slit to fit over roof penetrations and cut out around roof drains and other openings.
 
<li>slit to fit over roof penetrations and cut out around roof drains and other openings.
 
</li></ol>
 
</li></ol>
<li>Filter fabric must extend up perimeter edges and ''curbs'' and must be placed loose (unattached) under metal counter flashings or wall finishes.  See also '''13.3.5 Cap, Counter and Base Flashings''' ''Linear Metal Flashings''.
+
<li>Filter fabric must extend up perimeter edges and ''curbs'' and must be placed loose (unattached) under metal counter flashings or wall finishes.  See also '''13.3.5 Cap, Counter and Base Flashings''' concerning ''linear metal flashings''.
 
</li></ol>
 
</li></ol>
 
+
<div id="PLAT_ROOF_COVERINGS"></div>
 
===Roof Coverings===
 
===Roof Coverings===
 +
<div id="PLAT_GRAVEL"></div>
 
====<big>Decorative Gravel</big>====
 
====<big>Decorative Gravel</big>====
 
<ol>
 
<ol>
Line 395: Line 386:
 
<li>Crushed gravel specified as a ''roof covering'' must be installed over a geotextile protection layer, or its equivalent, when the gravel is crushed or smaller than 12 mm (1/2”) in diameter.
 
<li>Crushed gravel specified as a ''roof covering'' must be installed over a geotextile protection layer, or its equivalent, when the gravel is crushed or smaller than 12 mm (1/2”) in diameter.
 
</li></ol>
 
</li></ol>
 
+
<div id="PLAT_WEARING"></div>
 
====<big>Wearing Surfaces and Living Spaces</big>====
 
====<big>Wearing Surfaces and Living Spaces</big>====
 
<ol>
 
<ol>
 
<li>Pavers and unit-type masonry, such as brick or stone, must be supported by
 
<li>Pavers and unit-type masonry, such as brick or stone, must be supported by
 
<ol>
 
<ol>
<li>proprietary (purpose-made) pedestals with at least a 3mm (⅛”) integral spacer ribs for uniform spacing of pavers.
+
<li>proprietary (purpose-made) pedestals with at least a 3mm (1/8”) integral spacer ribs for uniform spacing of pavers.
 
<li>a proprietary drainage layer overlaid with a filter fabric mat.
 
<li>a proprietary drainage layer overlaid with a filter fabric mat.
 
<li>a drainage layer of loose aggregate (such as pea gravel) measuring at least 25 mm (1") in depth, installed over a filter fabric.
 
<li>a drainage layer of loose aggregate (such as pea gravel) measuring at least 25 mm (1") in depth, installed over a filter fabric.
 
</li></ol>
 
</li></ol>
<li>Pedestals or a drainage layer must permit at least 12.7 mm (½″) of vertical separation between the paver and the underlying substrate, to provide airflow for drying surfaces and assist in leveling. <span class="principles">Pedestals should not impede the flow of water or air, and should uniformly distribute the dead load of pavers, and other unit masonry products, as well as predicted live loads</span>.
+
<li>Pedestals or a drainage layer must permit at least 12.7 mm (1/2″) of vertical separation between the paver and the underlying substrate, to provide airflow for drying surfaces and assist in leveling. <span class="principles">Pedestals should not impede the flow of water or air, and should uniformly distribute the dead load of pavers, and other unit masonry products, as well as predicted live loads</span>.
 
</li></ol>
 
</li></ol>
 
+
<div id="PLAT_VEGETATED"></div>
 
====<big>Vegetated Roof Systems</big>====
 
====<big>Vegetated Roof Systems</big>====
 
<ol>
 
<ol>
Line 415: Line 406:
 
<li>filter cloth.
 
<li>filter cloth.
 
</li></ol>
 
</li></ol>
<li><span class="principles">Roofs that support built-in-place soil or growing media beds should include an additional penetration-resistant protection course between the growing bed and other vegetated assembly materials.  The protection course prevents damage to these materials whenever sharp-pointed or edged tools are used for the maintenance of the ''Vegetated Roof System''</span>.
+
<li><span class="principles">Roofs that support built-in-place soil or growing media beds should include an additional penetration-resistant protection course between the growing bed and other ''Vegetated Roof System'' materials.  The protection course prevents damage to these materials whenever sharp-pointed or edged tools are used for the maintenance of the ''Vegetated Roof System''</span>.
 
<li>Root intrusion barriers must be
 
<li>Root intrusion barriers must be
 
<ol>
 
<ol>
Line 440: Line 431:
 
</li></ol>
 
</li></ol>
 
</li></ol>
 
</li></ol>
 
+
<div id="PLAT_STRUCTURES"></div>
 
===Structures and Equipment===
 
===Structures and Equipment===
 
<ol>
 
<ol>
Line 450: Line 441:
 
<li>'''Pre‐curbs''' must be
 
<li>'''Pre‐curbs''' must be
 
<ol>
 
<ol>
<li>at least 100 mm (4") in height above the water plane of the highest adjacent roof assembly (see Construction Detail [http://rpm.rcabc.org/index.php?title=SBS_14.3.3_Structures_and_Equipment_(planter_pre-curb) '''SBS 14.3.3 Structures and Equipment (planter pre-curb)'''] as an example).
+
<li>at least 100 mm (4") in height above the ''drainage plane'' of the highest adjacent ''roof assembly'' (see Construction Detail [http://rpm.rcabc.org/index.php?title=SBS_14.3.3_Structures_and_Equipment_(planter_pre-curb) '''SBS 14.3.3 Structures and Equipment (planter pre-curb)'''] as an example).
 
<li>completely enveloped with fully adhered acceptable membrane flashing (including all faces of drainage knock‐outs).
 
<li>completely enveloped with fully adhered acceptable membrane flashing (including all faces of drainage knock‐outs).
 
</li></ol>
 
</li></ol>
Line 456: Line 447:
 
<br>
 
<br>
 
{| class="wikitable"; table style="background-color:white"; border="#A9A9A9;"
 
{| class="wikitable"; table style="background-color:white"; border="#A9A9A9;"
|+{{hilite | <small>Figure 14.3.1</small> || 2021-February-7 }}
+
|+{{hilite | '''Figure 14.3.1''' (Click to expand) || 2021-February-7 }}
 
|-
 
|-
 
| [[File:SBS Figure 14.3.1.jpg|link=http://rpm.rcabc.org/images/5/5b/SBS_Figure_14.3.1.jpg | 350 px]]
 
| [[File:SBS Figure 14.3.1.jpg|link=http://rpm.rcabc.org/images/5/5b/SBS_Figure_14.3.1.jpg | 350 px]]
Line 463: Line 454:
 
<ol>
 
<ol>
 
<li>inserted into the pre‐curb after application of the membrane flashing.
 
<li>inserted into the pre‐curb after application of the membrane flashing.
<li>waterproofed {{hilite | in their final position, where they penetrate the pre-curb,|| 2021-February-7 }} using either a reinforced 2-part liquid membrane flashing or two (2) applications of a single-component liquid membrane flashing (fully cured between coats),  
+
<li>waterproofed {{hilite | in their final position, where they penetrate the pre-curb,|| 2021-February-7 }} using either a reinforced 2-component liquid membrane flashing or two (2) applications of a single-component liquid membrane flashing (fully cured between coats),  
 
<ol>
 
<ol>
 
<li>applied to properly prepared surfaces.
 
<li>applied to properly prepared surfaces.
<li>in keeping with the application standards in '''11.3.3.3 Liquid Membrane Flashing''' for 2-part reinforced liquid membrane flashing, or the manufacturer’s instructions for single-component liquid membrane flashing.
+
<li>in keeping with the application standards in '''11.3.3.3 Liquid Membrane Flashing''' for 2-component reinforced liquid membrane flashing, or the manufacturer’s instructions for single-component liquid membrane flashing.
 
<li>applied no less than 50 mm (2”) on vertical surfaces and {{hilite | in a radius ||2021-February-7 }} around the base of each dowel.
 
<li>applied no less than 50 mm (2”) on vertical surfaces and {{hilite | in a radius ||2021-February-7 }} around the base of each dowel.
 
</li></ol>
 
</li></ol>
 
</li></ol>
 
</li></ol>
<li>Structural planters and water features constructed on pre-curbs must be waterproofed on the inside with a fully‐adhered membrane that terminates on the inside vertical surface of the planter at least 100 mm (4”) above the level of soil, growing medium or water, or at the outside edge of the top surface of the planter or water feature wall.
+
<li>Structural planters and water features constructed on pre-curbs must be waterproofed on the inside with a fully‐adhered membrane that terminates on the inside vertical surface of the planter at least 100 mm (4”) above the level of soil, growing medium or water, or at the outside edge of the top surface of the planter or water feature ''wall''.
 
<li>Membranes must be terminated in keeping with the standards in '''Part 11 DRAINS and PENETRATIONS''' and protected with metal reglet or cap flashings in keeping with '''Part 13 METAL FLASHINGS'''.
 
<li>Membranes must be terminated in keeping with the standards in '''Part 11 DRAINS and PENETRATIONS''' and protected with metal reglet or cap flashings in keeping with '''Part 13 METAL FLASHINGS'''.
 
<li>A membrane integrity scan and any resulting repairs must be undertaken before the membrane is covered or submerged.
 
<li>A membrane integrity scan and any resulting repairs must be undertaken before the membrane is covered or submerged.
 
</li></ol>
 
</li></ol>

Latest revision as of 19:34, 12 November 2021

1 General

  1. This Part covers the design and installation requirements for roofs that support an overburden, whether it is structurally supported or non-structurally situated on the roof platform. Overburdens include
    1. Roof Coverings (including, without limitation)
      1. gravel.
      2. wearing surfaces and living spaces (rooftop terraces) – pavers, wood or composite decks and walkways, cast-in-place concrete, rubberized surfaces and playscapes, pet relief areas.
      3. gardens/vegetated assemblies (modular and built-in-place).
    2. Structures and Equipment (including, without limitation)
      1. planters.
      2. furnishings.
      3. hot tubs.
      4. gazebos, pergolas, nets and wind screens.
      5. housekeeping pads.
      6. photovoltaics.
      7. elevated walkways and stairs; satellite equipment; light standards; signage; lightning rods; sculptures.
      8. structural planters, pools and other water features.
    3. Any roof covering, structure or item of equipment must be installed in a manner that protects the roof membrane and its performance.
    4. Coverage under the RoofStar Guarantee may be affected by roof coverings or equipment that impede access to the roof system. Refer to Part 1 General in this Standard.

1.1 Definitions

Refer to the Glossary for further definitions of key terms used in this Manual.

Extensive Vegetated Roof Systems
sometimes referred to as "eco-roofs", 'low-profile green roofs," "rooftop gardens" or simply as "green roofs"
  1. are installed and maintained without the use of penetrating hand tools.
  2. utilize pre-assembled trays, boxes, mats or other contained soil or media.
  3. have minimal plant species diversity.
  4. are irrigated only to establish plants.
  5. have a soil depth no more than 150 mm (6").
  6. are not normally accessed by building occupants.
Inaccessible Overburden
means an overburden that must be demolished in order to access the roof membrane. A concrete split slab is a type of inaccessible overburden.
Overburden
(also referred to as a wearing course or layer) means a roof covering, structure or item of equipment that is situated on top of, and covering all or a portion of, a constructed waterproofing system. Overburden includes, without limitation,
Roof Coverings
  1. loose growing media, gravel (used as a covering, not exclusively as ballast), sand or any other granular material.
  2. void fill.
  3. tiles, pavers, supporting pedestals or other similar materials.
  4. vegetated assemblies in trays, mats, other similar containers.
  5. cast-in-place concrete.
  6. playing surfaces.
  7. pet relief areas.
Structures
  1. planters, inclusive of everything they contain
  2. gazebos, decks, benches.
  3. water features & hot tubs.
Equipment
  1. satellite / Communications.
  2. lightning rods.
  3. photovoltaics.
  4. signage and lighting.
Roof Platform
means a roof assembly which supports an overburden or living (amenity) space consisting of coverings, structures or equipment that are not part of the assembly.

1.2 Design

Membrane roof systems may be utilized for more than simple weather protection; they can be occupied by casual or regular users, for gardening, playing, lounging, or other leisure activities. Roofs that serve as amenity spaces require that the Design Authority pay particular attention to the system selection itself and, especially, to the protection of the roof membrane.

A Conventionally Insulated System is not appropriate for all types of use or roof coverings. For example, the designed live loading for occupied spaces, or the weight of a roof covering, may require the Design Authority to specify particular materials, and consequently to design a roof as a Protected Membrane Roof System. Furthermore, some roof coverings require maintenance that may result in damage to Conventionally Insulated Systems; Protected Membrane Roof Systems shield the sensitive membrane from this inevitability.

A Protected Membrane Roof System (often referred to as an "inverted roof") offers the designer many benefits, including

  • longer lasting membranes.
  • capacity for heavier dead and live loads.
  • only one control layer to seal and join with the rest of the building envelope.
  • fewer waterproofing challenges around penetrations.
  • the capacity for electronic leak detection (whether passive or monitored).


For RoofStar Guarantee Standards pertaining to the securement of a ballasted Protected Membrane Roof Systems, refer to Part 3 SECURING the ROOF ASSEMBLY, 3.3.2 Ballasted Roof Assemblies.

Criteria for evaluating the sensitivity of building interiors is left to the Design Authority.

This Subsection is written to provide guidance by way of general standards and guiding principles, to assist the Design Authority in making the best possible choices for the roof assembly.

1.2.1 General

  1. The building structure must be designed to support any live loads specified by the Code having jurisdiction. This includes loads from any covering, amenity space, structure or live loads superimposed upon the roof platform.
  2. The Design Authority should give thought to the inevitability of roof repairs or replacement when designing the coverings, living spaces or structures the roof will support. This includes, without limitation,
    1. access for maintenance.
    2. material removal, storage and replacement logistics.
  3. The Design Authority is responsible for the appropriate securement design of coverings, living (amenity) spaces and structures, to resist anticipated Specified Wind Loads. Where structural securement is desirable or required, it must be made to fully waterproofed structural supports (curbs, sleepers, posts) and must be secured to the structural support at least 200 mm (8”) above the water plane. See Part 11 PENETRATIONS and DRAINS. See also Part 3 SECURING the ROOF ASSEMBLY.
  4. A roof designed and constructed as a Protected Membrane Roof System is strongly recommended when the roof covering or living (amenity) space
    1. exceeds 150 mm (6”) in depth (excluding any plants).
    2. is an intensive or semi-intensive Vegetated Roof System.
    3. includes cast-in-place concrete surfaces.
    4. is installed over a podium roof area adjacent to residential high-rise structures.
    5. includes water features or pools.
    6. includes expansive terrace areas or play spaces.
  5. Roofs designed as platforms for coverings, amenity spaces and equipment must take into account the following standards and guiding principles:
    1. Load bearing:
      1. Non-structural installations: Insulation and insulation overlays used in a Conventionally Insulated System or Modified Protected Membrane Roof System must have a minimum load carrying capacity of 110 Kpa (20 psi), but in any event must be capable of supporting any superimposed loads on the exposed membrane, without compression or distortion of the roof system or any one of its components. Otherwise, the roof platform must be designed as a Protected Membrane Roof System. See also 8.1.1 Design (Insulation Overlays).
      2. Structural installations - structural supports (i.e. curbs) should be considered to bear heavier dead loads, to resist Specified Wind Loads, or to secure the equipment during seismic events.
    2. Membrane thickness and puncture resistance: Membranes must be selected for their ability to resist accidental puncture by human activity on the roof; the minimum puncture resistance must be at least 400 N. Refer to the table in 9.1.2 for minimum membrane thickness and puncture resistance requirements.
    3. Protection:
      1. Membranes must be protected from damage incurred
        1. during the construction of a building.
        2. from normal use and occupancy of the roof.
        3. from maintenance of any installation on top of a roof system, after the building has been commissioned.
      2. To prevent accidental damage and puncture from falling objects, Conventional Insulated Systems at elevations lower than those designed for human occupancy should include a protective wearing course or, in the alternative, should be designed as a Protected Membrane Roof System.
      3. Where membranes installed on vertical surfaces may be damaged from foot traffic or shifting coverings, they must be protected as, for example, with base metal flashings. See 13.3.5 Cap, Counter and Base Flashings.
      4. Filter fabrics are required for roof platforms supporting
        1. growing media and vegetation.
        2. sand and other fine materials.
        3. gravel with a diameter less than 12.7 mm (1/2”).
        4. wet mortar or concrete.
        5. XPS insulation above the membrane, in order to contain the insulation and thereby prevent ‘insulation stacking’ (displacement) when insulation boards become buoyant in water, and to prevent "fines" from settling at the membrane level and filling the voids between insulation board joints.
    4. Drainage:
      1. Roofs designed as platforms to support roof coverings, amenity spaces or equipment must promote unimpeded drainage of storm or irrigation water. Where a roof covering material naturally drains (gravel, for example), no additional drainage design is required. In all other cases, the design must incorporate a drainage plane above the supporting roof platform.
      2. Overburden must be contained with drain guards, rigid barriers and filter fabric. See also 11.2.2 Roof Drains and Scuppers.
      3. Equipment supports placed on the roof system must not impede the flow of water to drains. To facilitate the adequate movement of water when supports are oriented perpendicular to drainage flow,
        1. utilize shorter supports, to a maximum length of 1200 mm (4’).
        2. incorporate drainage mats beneath the supports longer than 1200 mm (4’) in any direction.
    5. Clearance and accessibility: equipment installed on structural supports or on top of the roof system must be spaced or located to promote access to drains, ease of maintenance and worker or occupant safety.
    6. An Integrity Scan: see 1.6 (7) (1.6 RoofStar Guarantee: Coverage and Limitations).
    7. Electronic Leak Detection is mandatory for grade-level waterproofing systems, but optional for roof Waterproofing Systems.

      See 1.3.4 Waterpoofing Integrity Scans and Electronic Leak Detection. See also 1.6 RoofStar Guarantee: Coverage and Limitations.

1.2.2 Roof Coverings

1.2.2.1 Gravel

Note that gravel used as ballast on a Protected Membrane Roof System or Modified Protected Membrane Roof System is considered a means of securement and is covered in Part 3 SECURING the ROOF ASSEMBLY and in 12.1 Protected and Modified Protected Membrane Systems.

  1. When gravel is specified as the roof covering,
    1. the design must include gravel guards around roof drains.
    2. only washed gravel may be used.
  2. When the gravel used as a roof covering is crushed, or is smaller than 12 mm (1/2”),
    1. a geotextile protection layer must be installed immediately above the roof membrane.
    2. the gravel must be deep enough to retain the geotextile protection layer.
1.2.2.2 Wearing Surfaces and Living Spaces
  1. Any wearing surface may be installed on a Conventionally Insulated System, provided
    1. the compressive strength of the insulation will support it.
    2. the insulation in the roof assembly is overlaid with a suitable insulation overlay (see 8.3.1.2 (4)).
    3. the wearing surface does not bond with or touch the roof field membrane or membrane flashing.
    4. drainage of storm or irrigation water is not impeded.
  2. When concrete paver walkways or platforms are specified, they must promote free drainage of water. This can be achieved by using adequately spaced
    1. pedestals.
    2. proprietary pads.
    3. XPS insulation.
    4. drainage mats.
  3. Wearing surfaces may be sloped or level, depending upon the intent of the design, and therefore project specifications and drawings should indicate this.
  4. When cast-in-place concrete is used as a roof covering directly over the roof membrane, the concrete must be separated from the membrane with both of the following:
    1. A bond-breaking material, such as a proprietary drainage mat or XPS insulation.
    2. A filter fabric or barrier material acceptable to the membrane manufacturer, able to prevent the concrete slurry from reaching the membrane.
1.2.2.3 Vegetated Roof Systems
  1. Vegetated Roof Systems (VRS) must be designed to resist the Specified Wind Loads calculated using the WIND-MVRA online calculator (see also Part 3 SECURING the ROOF ASSEMBLY). Since Vegetated Roof Systems often provide ballast for Protected Membrane Roof Systems and may be installed by someone other than the Contractor, the Design Authority must specify the coordination of work to ensure the roof system is immediately and properly secured.
  2. Conventionally Insulated Systems may be used to support any type of Vegetated Roof System, provided
    1. the compressive strength of the insulation will support it.
    2. the insulation in the roof system is overlaid with a suitable insulation overlay (see 8.3.1.2 (4)).
    3. the membrane manufacturer is agreeable to the application and is confident the membrane can withstand the anticipated hydrostatic pressures when the Vegetated Roof System is fully saturated with water.
    4. the membrane is fully adhered.
  3. Notwithstanding the above, Semi-intensive and Intensive Vegetated Roof Systems should be designed as part of a Protected Membrane Roof System. See also 14.1.2.1 (4) above.
  4. Every roof that supports a Vegetated Roof System must have, in addition to a drainage layer and membrane protection, a
    1. root barrier.
    2. filter fabric layer.
  5. Vegetated Roof Systems that are built in place should be designed with an additional layer of protection immediately below the growing media and above the rest of the roof system, to ensure the protection of these materials from tools.
  6. Separation Zones, which are free of growing media or vegetation and protect vulnerable membrane seams from root damage, must be
    1. at least 300 mm (12”) wide, or greater as determined through Specified Wind Load calculations (see also Part 3 SECURING the ROOF ASSEMBLY).
    2. bordered by a non-penetrating, surface-installed physical barrier (for example, a retention Tee).
    3. installed around the perimeter of the Vegetated Roof System, and around any of the following, which may be contained within the area covered by the Vegetated Roof System:
      1. roof drains.
      2. roof penetrations.
      3. sleepers and curbs.
      4. any mechanical equipment not supported by a curb.
      5. expansion or control joints.
  7. Membrane flashing must be protected from damage, both during the installation of a Vegetated Roof System and during ongoing maintenance. Refer to Part 13 METAL FLASHINGS for guidance.

1.2.3 Structures and Equipment

  1. Refer to the general design standards and guidelines in 14.1.2.1 General.
  2. Non-structural installations
    1. are strongly recommended whenever practical, since they
      1. minimize the number of penetrations, curbs or sleepers necessary for structural securement.
      2. eliminate possible weak points in the roof system, where a leak may occur.
      3. avoid dedicated mechanical drainage.
      4. simplify removal of materials when membrane repairs are required.
    2. must be placed on an appropriate protection layer or supported by pedestals, pavers or other means of distributing weight and point loading.
    3. may be placed on a Conventionally Insulated System provided the insulation is capable of supporting all anticipated dead loads, live loads and point loads (see 14.1.2.1 (1)).
  3. A structural concrete planter or water feature that is
    1. cast-in-place should be constructed on a pre‐curb that is continuously waterproofed as part of the primary roof membrane and waterproofed independently of the primary roof membrane.
    2. pre-cast must be secured to
      1. a pre‐curb that is continuously waterproofed as part of the primary roof membrane.
      2. structural supports that are waterproofed in keeping with the Standards in Part 11 PENETRATIONS and DRAINS.
  4. When concrete walls or structures are constructed without a pre-curb, all concrete surfaces must be fully and continuously enveloped with the primary roof membrane. See also 1.6 (9).
  5. Pre‐curbs must be
    1. at least 100 mm (4") in height above the drainage plane of the highest adjacent roof assembly.
    2. completely enveloped with fully adhered acceptable membrane flashing (including all faces of drainage knock‐outs).
    3. properly waterproofed around dowels in their final position with either of the following:
      1. a 2-component catalyzed polymethyl methacrylate (PMMA) reinforced liquid membrane flashing system.
      2. two cured coats of an Accepted polyurethane or silicon-based single-component liquid flashing system. See 11.3.3.1 General for application standards.
  6. When a structural planter adjoins a Protected Membrane Roof System, the planter design must include either of the following options for drainage:
    1. a plumbed mechanical drain that
      1. incorporates a debris guard and maintenance access.
      2. extends above the top surface of the growing media at least 50 mm (2”).
    2. drainage knock-outs in the pre-curb wall, which should be wide enough to allow for the free flow of water over or past of the membrane flashing plies.
  7. When a structural planter adjoins a Conventionally Insulated System, only a plumbed mechanical drain is permissible.
  8. A design review is advisable when a structural water features incorporates penetrations for wiring, lights or other submerged features.
  9. Tiles or other architectural finishes may be applied to the waterproofing membrane, subject to a written Variance from the Guarantor and approval by the membrane manufacturer.
  10. Drains, re-circulation inlets and outlets used in water features must include clamping rings and must be sealed to the membrane assembly.
  11. When a leak detection system is specified, or required, only non‐ferrous metal drains may be used.
  12. Drain connections to internal piping must be made with mechanical compression type seals only.

2 Materials

2.1 Membranes

  1. Refer to the table in 9.2.1 for minimum membrane thickness and puncture resistance requirements.

2.2 Membrane Protection

  1. Membranes must be protected by using one of the following materials directly above the roof membrane:
    1. drainage mat.
    2. asphaltic core board measuring at least 3 mm (1/8”) thick.
    3. XPS insulation measuring at least 25 mm (1”) thick.
    4. a geotextile protection layer with a minimum thickness/weight of 200 g/m2 (used in Vegetated Roof System applications, where decorative gravel is crushed or smaller than 12 mm (1/2”) in diameter, or where the roof covering, superimposed structure or equipment does not exceed the load-bearing capacity of the protection material).

2.3 Insulation and Insulation Overlays

See also Part 7 INSULATION

  1. Insulation used in a Protected Membrane Roof System must be extruded polystyrene foam Insulation (XPS).
  2. When XPS (with or without a concrete topping) is specified as the drainage layer, it must be grooved (by the manufacturer or as a post-manufacturing alteration).
  3. Insulation that supports an acceptable roof covering must have a minimum compressive strength equal to or exceeding the dead loads and anticipated overall live loads and point loads of the overburden.
  4. When an insulation overlay is required (see 14.1.2.2), it must be a composite product
    1. no less than 12.7 mm (1/2") thick.
    2. with a minimum compressive strength of 620 kPa (90 psi).

2.4 Components for Vegetated Roof Systems and Other Roof Coverings

  1. While drainage mats, filter fabrics, root barriers and other Vegetated Roof System components are ancillary to the roof assembly, they nevertheless must be
    1. acceptable to the manufacturer of the primary membrane and XPS insulation (when used).
    2. suitable for the installed roof covering.
    3. selected for their ability to support dead loads, live loads and point loads.
    4. capable of permitting the anticipated flow rate of water.
  2. Geosynthetic drainage cores, and geocomposites with factory-laminated filter fabrics, must
    1. be molded (dimpled) or woven plastic grids so that it contacts no more than 40% of XPS insulation surface area.
    2. be manufactured with a minimum thickness of 9.5 mm (3/8”).
    3. provide a uniform support for roof coverings, structures or equipment installed on the roof platform.
    4. have a compressive strength equal to or greater than the design and anticipated live loads of the roof platform and the coverings, structures or equipment it supports.
  3. Fabric filter mats must be
    1. water permeable and have proven long term weather resistance.
    2. strong enough to withstand traffic abuse and prevent displacement of insulation boards under flotation conditions.
  4. Root intrusion barriers
    1. must be sheets or boards that are acceptable to the primary roof membrane manufacturer.
    2. may be polyethylene or polypropylene sheeting, provided the material is no less than 0.2mm (8 mils) thick.
  5. Membrane protection must be either of the following materials:
    1. asphaltic core board measuring at least 3 mm (1/8”) thick.
    2. XPS insulation measuring at least 25 mm (1”) thick.
    3. a geotextile protection layer with a minimum thickness/weight of 200 g/m2 (applicable when the gravel is crushed or smaller than 12 mm (1/2”) in diameter).
  6. Moisture retention and reservoir layers must be acceptable to the manufacturer/supplier of the Vegetated Roof System.

2.5 Decorative Gravel

  1. Decorative gravel (different in function from gravel ballast) must be washed and may be smooth or crushed.
  2. Large grade gravel may withstand wind scour more effectively than smaller gravel. The Design Authority should determine the gradients, based on the Specified Wind Loads for the roof. For size options, see 12.1.2 (6) for Protected Membrane Roof Systems.

2.6 Pavers and Pedestals

  1. Pavers that are partially supported (i.e. with pedestals) should be capable of resisting anticipated loads (consider, for example, hydraulically pressed concrete pavers).
  2. Pedestals
    1. should be adjustable, when a level surface is required.
    2. must be proprietary (purpose-made) and include an integral spacer rib measuring at least a 3mm (1/8”), to uniformly separate pavers.

3 Application

3.1 General

3.1.1 Membranes

  1. Membranes and membrane flashing must be installed in keeping with the requirements found elsewhere in this Standard.
  2. Protection of roof membranes from mechanical damage caused by tools, accident or the work of others is mandatory during the installation and maintenance of any roof covering or living space.

3.1.2 Drainage

  1. A drainage mat must be installed below the XPS insulation. A second drainage layer may be installed above the insulation, but this is at the discretion of the Design Authority.
  2. Specialized proprietary drainage products must be acceptable to the membrane manufacturer.

3.1.3 Filter Fabric

  1. Fabric filter mats must be
    1. installed loose-laid (un-bonded) over the insulation and below any type of ballast or roof covering.
    2. overlapped at all edges a minimum of 300mm (12").
    3. at least 2.5 m x 2.5 m (8’ x 8’) in size.
    4. slit to fit over roof penetrations and cut out around roof drains and other openings.
  2. Filter fabric must extend up perimeter edges and curbs and must be placed loose (unattached) under metal counter flashings or wall finishes. See also 13.3.5 Cap, Counter and Base Flashings concerning linear metal flashings.

3.2 Roof Coverings

3.2.1 Decorative Gravel

  1. When gravel is specified as a roof covering, only washed gravel may be used.
  2. Ballast guards must be installed around all roof drains. See 11.2.2 Roof Drains & Scuppers.
  3. Crushed gravel specified as a roof covering must be installed over a geotextile protection layer, or its equivalent, when the gravel is crushed or smaller than 12 mm (1/2”) in diameter.

3.2.2 Wearing Surfaces and Living Spaces

  1. Pavers and unit-type masonry, such as brick or stone, must be supported by
    1. proprietary (purpose-made) pedestals with at least a 3mm (1/8”) integral spacer ribs for uniform spacing of pavers.
    2. a proprietary drainage layer overlaid with a filter fabric mat.
    3. a drainage layer of loose aggregate (such as pea gravel) measuring at least 25 mm (1") in depth, installed over a filter fabric.
  2. Pedestals or a drainage layer must permit at least 12.7 mm (1/2″) of vertical separation between the paver and the underlying substrate, to provide airflow for drying surfaces and assist in leveling. Pedestals should not impede the flow of water or air, and should uniformly distribute the dead load of pavers, and other unit masonry products, as well as predicted live loads.

3.2.3 Vegetated Roof Systems

  1. All Vegetated Roof Systems must be installed as specified and shown on drawings, and in any case must include a
    1. root barrier.
    2. drainage layer.
    3. filter cloth.
  2. Roofs that support built-in-place soil or growing media beds should include an additional penetration-resistant protection course between the growing bed and other Vegetated Roof System materials. The protection course prevents damage to these materials whenever sharp-pointed or edged tools are used for the maintenance of the Vegetated Roof System.
  3. Root intrusion barriers must be
    1. installed in a continuous plane above the roof membrane.
    2. located within the Vegetated Roof System as specified by the Design Authority.
    3. sealed at all seams and laps with a compatible tape, as directed by the manufacturer's instructions.
    4. carried up the inside of soil retention perimeters (separation zones).
    5. sealed to the Separation Zone edge material.
  4. Separation Zones must be
    1. at least 300 mm (12”) wide.
    2. bordered by a non-penetrating, surface-installed physical barrier.
    3. installed along all roof perimeters.
    4. installed around
      1. up-stands.
      2. roof drains.
      3. penetrations.
      4. sleepers and curbs. mechanical equipment.
      5. expansion or control joints.

3.3 Structures and Equipment

  1. Structural planters and water features (pools, ponds, water courses) must be constructed with
    1. a pre‐curb (start‐up curb), onto which the planter or water feature wall is formed and poured.
    2. full-height walls that are formed and poured in direct contact with the structural deck.
  2. Pre‐curbs must be
    1. at least 100 mm (4") in height above the drainage plane of the highest adjacent roof assembly (see Construction Detail SBS 14.3.3 Structures and Equipment (planter pre-curb) as an example).
    2. completely enveloped with fully adhered acceptable membrane flashing (including all faces of drainage knock‐outs).
  3. Full-height walls must be fully enveloped with roof membrane, on all faces. See Figure 14.3.1.
    Figure 14.3.1 (Click to expand)
    SBS Figure 14.3.1.jpg
  4. Dowels (reinforcement bar) must be
    1. inserted into the pre‐curb after application of the membrane flashing.
    2. waterproofed in their final position, where they penetrate the pre-curb, using either a reinforced 2-component liquid membrane flashing or two (2) applications of a single-component liquid membrane flashing (fully cured between coats),
      1. applied to properly prepared surfaces.
      2. in keeping with the application standards in 11.3.3.3 Liquid Membrane Flashing for 2-component reinforced liquid membrane flashing, or the manufacturer’s instructions for single-component liquid membrane flashing.
      3. applied no less than 50 mm (2”) on vertical surfaces and in a radius around the base of each dowel.
  5. Structural planters and water features constructed on pre-curbs must be waterproofed on the inside with a fully‐adhered membrane that terminates on the inside vertical surface of the planter at least 100 mm (4”) above the level of soil, growing medium or water, or at the outside edge of the top surface of the planter or water feature wall.
  6. Membranes must be terminated in keeping with the standards in Part 11 DRAINS and PENETRATIONS and protected with metal reglet or cap flashings in keeping with Part 13 METAL FLASHINGS.
  7. A membrane integrity scan and any resulting repairs must be undertaken before the membrane is covered or submerged.