<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>http://rpm.rcabc.org/index.php?action=history&amp;feed=atom&amp;title=TPO_Low_Door_Opening</id>
	<title>TPO Low Door Opening - Revision history</title>
	<link rel="self" type="application/atom+xml" href="http://rpm.rcabc.org/index.php?action=history&amp;feed=atom&amp;title=TPO_Low_Door_Opening"/>
	<link rel="alternate" type="text/html" href="http://rpm.rcabc.org/index.php?title=TPO_Low_Door_Opening&amp;action=history"/>
	<updated>2026-04-29T04:46:39Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.31.1</generator>
	<entry>
		<id>http://rpm.rcabc.org/index.php?title=TPO_Low_Door_Opening&amp;diff=52953&amp;oldid=prev</id>
		<title>James Klassen at 16:23, 7 November 2025</title>
		<link rel="alternate" type="text/html" href="http://rpm.rcabc.org/index.php?title=TPO_Low_Door_Opening&amp;diff=52953&amp;oldid=prev"/>
		<updated>2025-11-07T16:23:56Z</updated>

		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{{Template:RPM Info}}&lt;br /&gt;
&lt;br /&gt;
{{DISPLAYTITLE:&amp;lt;span style=&amp;quot;position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);&amp;quot;&amp;gt;{{FULLPAGENAME}}&amp;lt;/span&amp;gt;}}&lt;br /&gt;
__NOTOC__&lt;br /&gt;
&lt;br /&gt;
&amp;lt;big&amp;gt;&amp;lt;big&amp;gt;Division D - Construction Details&amp;lt;/big&amp;gt;&amp;lt;/big&amp;gt;&lt;br /&gt;
&amp;lt;hr&amp;gt;&lt;br /&gt;
&amp;lt;big&amp;gt;&amp;lt;big&amp;gt;&amp;lt;big&amp;gt;&amp;lt;big&amp;gt;&amp;lt;big&amp;gt;TPO | Low Door Opening ([[TPO_Roof_Systems_Standard#10.3.4.5._Doors.2C_Windows.2C_and_Wall_Openings | Article 10.3.4.5.]])&amp;lt;/big&amp;gt;&amp;lt;/big&amp;gt;&amp;lt;/big&amp;gt;&amp;lt;/big&amp;gt;&amp;lt;/big&amp;gt;&lt;br /&gt;
{{Template:Construction Details Header}}&lt;br /&gt;
&amp;lt;div class=&amp;quot;panel panel-info&amp;quot;&amp;gt;&lt;br /&gt;
&amp;lt;div class=&amp;quot;panel-heading&amp;quot;&amp;gt;&amp;lt;big&amp;gt;'''TPO Details'''&amp;lt;/big&amp;gt;&amp;lt;/div&amp;gt;&lt;br /&gt;
&amp;lt;div class=&amp;quot;panel-body&amp;quot;&amp;gt;&lt;br /&gt;
&amp;lt;div class=&amp;quot;col-md-6&amp;quot;&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;div style=&amp;quot;text-align:center; vertical-align:center&amp;quot;&amp;gt;&lt;br /&gt;
[[File:Part 10 - Construction Detail - Low Door Opening - TPO.png|link=https://rpm.rcabc.org/images/3/32/Part_10_-_Construction_Detail_-_Low_Door_Opening_-_TPO.png |class=img-responsive]]&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&amp;lt;/div&amp;gt;&amp;lt;!-- COL-MD-6 --&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div class=&amp;quot;col-md-6&amp;quot;&amp;gt;&lt;br /&gt;
=== WORK INCLUDED ===&lt;br /&gt;
;(1) [[TPO Roof Systems Standard#PART_1|'''Roof system''']]: Conventionally insulated system shown (refer to the membrane Standard for requirements).&lt;br /&gt;
;(2) [[TPO Roof Systems Standard#PART_9|'''Field membrane''']]: TPO shown (see Part 9 for requirements)&lt;br /&gt;
;(3) [[TPO Roof Systems Standard#PART_10|'''Self-adhered membrane (pre-flashing)''']]: Adhered.  Apply over rough sill or sill woodwork.  Prime as required.&lt;br /&gt;
;(4) [[TPO Roof Systems Standard#PART_10|'''Metal water-stop flashing''']]: Dimensions as specified in design.  Mechanically attach to inside face of door sill.  Cut flashing to fit opening width.&lt;br /&gt;
;(5) [[TPO Roof Systems Standard#PART_10|'''Membrane flashing (not shown)''']]: Optional, if field membrane stops at edge securement. Install to overlap and seal in metal water-stop flashing.&lt;br /&gt;
;(6) [[TPO Roof Systems Standard#PART_10|'''Membrane corner reinforcement''']]: Install as required by the Standard and the ''manufacturer''.&lt;br /&gt;
;(7) [[TPO Roof Systems Standard#PART_13|'''Metal base flashing (under door)''']]: Optional; protection for membrane when pavers are installed (shown), or when exposed membrane is vulnerable to damage.  Mechanical fasteners must be at least 87.5 mm (3-1/2”) above the drainage plane.&lt;br /&gt;
;(8) [[TPO Roof Systems Standard#PART_10|'''Membrane flashing (not shown)''']]: Optional, if field membrane stops at edge securement. Applicable for exterior-insulated walls. Seals roof membrane flashing to air/vapour barrier on wall and provides sufficient exposure for positive union with WRB (by others). Mechanically secure membrane (metal base flashing used for securement in this detail).&lt;br /&gt;
;(9) [[TPO Roof Systems Standard#PART_10|'''Metal base flashing (walls)''']]: Optional; protects membrane flashing from damage, and functions as removable panel to permit access to membrane flashing for future replacement.&lt;br /&gt;
;(10) [[TPO Roof Systems Standard#PART_14|'''Pavers and pedestals''']]: May be installed by others, if specified.  See '''Part 14''' for material and application requirements.  Must be at least 12 mm (1/2”) away from other pavers, and from membrane flashing or metal base flashing, to permit adequate drainage.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;hr&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=== RELATED WORK BY OTHERS ===&lt;br /&gt;
;(A) '''Wall and cladding''': Generic and representative only.&lt;br /&gt;
;(B) '''WRB (Water Resistive Barrier)''': Generic and representative only.&lt;br /&gt;
;(C) '''Door and jamb assembly''': Generic and representative only.&lt;br /&gt;
&amp;lt;/div&amp;gt;&amp;lt;!-- COL-6-MD --&amp;gt;&lt;br /&gt;
&amp;lt;/div&amp;gt;&amp;lt;!-- PANEL BODY --&amp;gt;&lt;br /&gt;
&amp;lt;/div&amp;gt;&amp;lt;!-- PANEL --&amp;gt;&lt;br /&gt;
&lt;br /&gt;
'''NOTE''': See the [[TPO Roof Systems Standard | '''Standard''']] for additional requirements.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;hr&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[TPO Roof System Details|&amp;lt;i class=&amp;quot;fa fa-chevron-circle-left fa&amp;quot; &amp;gt;&amp;lt;/i&amp;gt; Back to ''TPO Roof System Details'']]&lt;br /&gt;
&lt;br /&gt;
[[RCABC Roofing Practices Manual| &amp;lt;i class=&amp;quot;fa fa-home fa&amp;quot;&amp;gt;&amp;lt;/i&amp;gt; Home]]&lt;br /&gt;
&lt;br /&gt;
{{Template:RPM Page Footer with Copyright and Current Date}}&lt;/div&gt;</summary>
		<author><name>James Klassen</name></author>
		
	</entry>
</feed>