;Accepted for '''''RoofStar Guarantee Program''''': Date TBA | ;Accepted for '''''RoofStar Guarantee Program''''': Date TBA | ||
;: | ;: | ||
| − | ;'''Product Summary''': | + | ;'''Product Summary''': |
| + | :'''Roof Assembly''': MECHANICALLY FASTENED MEMBRANE, INSULATED AND UN-INSULATED SYSTEMS | ||
| + | :Slope Limitation: Consult the manufacturer's product Specifications. | ||
| + | :;In-Service Performance Min.: | ||
| + | ::-26°c (-15°F) | ||
| + | :;Temperature of the Membrane: | ||
| + | ::Max.: 46°c (115°F) | ||
| + | |||
| + | |||
| + | :'''Roof Assembly''': ADHERED MEMBRANE, INSULATED AND UNINSULATED SYSTEMS | ||
| + | :Slope Limitation: Consult the manufacturer's product Specifications. | ||
| + | :;In-Service Performance Min.: | ||
| + | ::15°c (50°F) | ||
| + | :;Temperature of the Membrane: | ||
| + | ::Max.: 32°c (90°F) | ||
;: | ;: | ||
;[[Duro-Last PVC Membrane Installation Guidelines|Installation Guidelines]] | ;[[Duro-Last PVC Membrane Installation Guidelines|Installation Guidelines]] | ||
|} | |} | ||
| − | :Click below for the '''Technical Data Sheet''' | + | :Click below for the '''Technical Data Sheet''' |
| − | <div | + | <div class="col-md-2"> |
| − | :[[File:Pdf.png|150 px|link=http://rpm.rcabc.org/images/ | + | :[[File:Pdf.png|150 px|link=http://rpm.rcabc.org/images/8/81/Duro-Last_50_Mil_TDS.pdf|'''Technical Data Sheet (45 mil)''']] |
| + | <div style="text-align: center;"> | ||
| + | :1.27 mm (50 mil) Membrane TDS | ||
| + | </div> | ||
</div> | </div> | ||
| − | + | <div class="col-md-2"> | |
| − | + | :[[File:Pdf.png|150 px|link=http://rpm.rcabc.org/images/f/f5/Duro-Last_60_Mil_TDS.pdf|'''Technical Data Sheet (60 mil)''']] | |
| + | <div style="text-align: center;"> | ||
| + | :1.52 mm (60 mil) Membrane TDS | ||
| + | </div> | ||
| + | </div><div class="col-md-12"> | ||
<hr> | <hr> | ||
| Line 29: | Line 50: | ||
[[Main Page|Home]] | [[Main Page|Home]] | ||
| + | </div> | ||
Latest revision as of 13:59, 9 September 2021
| Notice to the Reader:
The roofing assembly / material information published in the RCABC Roofing Practices Manual and offered below does NOT represent a complete set of the manufacturer’s data or specifications. The preparation of a detailed specification is the responsibility of the design authority. |
Manufacturer: Duro-Last Roofing, Inc.
|
- Click below for the Technical Data Sheet