Difference between revisions of "Vegetated ("Green") Roof Systems"

Jump to: navigation, search

Difference between revisions of "Vegetated ("Green") Roof Systems"

(Replaced content with "{{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}} <div class="row"> <div class="co...")
(Tag: Replaced)
 
(12 intermediate revisions by the same user not shown)
Line 9: Line 9:
 
<hr>
 
<hr>
 
<big><big><big><big><big>Vegetated ("Green") Roof Systems (VRS)</big></big></big></big></big>
 
<big><big><big><big><big>Vegetated ("Green") Roof Systems (VRS)</big></big></big></big></big>
 
+
{{Template:Vegetated Roof Systems (Table)}}
{| class="wikitable sortable mw-datatable" style="margin-left: 20pt; margin-right: auto; border: none;"
 
|+ Vegetated Roof Systems<br><small>Click on a manufacturer's name to see the full list of their vegetated roof systems accepted for use in the RoofStar Guarantee Program.  Click on the System Name to see the materials and documentation for the system.<br>To reset this page to its original view, click your browser refresh button.
 
! style="width:200px;vertical-align:top;background-color:#b7c656;" | VRS Supplier
 
! style="width:300px;vertical-align:top;background-color:#cedf90;" | VR System Name <sup>‡</sup>
 
! style="vertical-align:top;background-color:#cedf90;" | VRS Type *
 
! style="width:100px;vertical-align:top;background-color:#EAF9C0;" | System<br>Min.<br>Depth<br>mm (in) <sup>**</sup>
 
! style="width:100px;vertical-align:top;background-color:#EAF9C0;" | System<br>Max.<br>Depth<br>mm (in)
 
! style="width:100px;vertical-align:top;background-color:#EAF9C0;" | Media<br>Min.<br>Depth<br>mm (in) <sup>**</sup>
 
! style="width:100px;vertical-align:top;background-color:#EAF9C0;" | Media<br>Max.<br>Depth<br>mm (in)
 
! style="width:100px;vertical-align:top;background-color:#EAF9C0;" | System<br>Saturated<br>Weight<br>Kg (lb) <sup>†</sup>
 
! style="width:100px;vertical-align:top;background-color:#EAF9C0;" | Stormwater Mgmt
 
! style="width:100px;vertical-align:top;background-color:#EAF9C0;" | Wind Resistance
 
|-
 
| [[Manufacturers:Carlisle SynTec Systems Canada | Carlisle SynTec Systems Canada]] || style="text-align:center;"| [[Materials:Carlisle Extensive Roof Garden System | Carlisle Extensive Roof Garden System]] || style="text-align:center;"| Extensive || style="text-align:center;"| 101.6 (4) || style="text-align:center;"| 127 (5) || style="text-align:center;"| 70 (1-1/4) || style="text-align:center;"| 127 (5) || style="text-align:center;"| - || style="text-align:center;"| Consult Manufacturer || style="text-align:center;"| Consult Manufacturer
 
|-
 
| [[Manufacturers:Carlisle SynTec Systems Canada | Carlisle SynTec Systems Canada]] || style="text-align:center;"| [[Materials:Carlisle Semi-Intensive Roof Garden System | Carlisle Semi-Intensive Roof Garden System]] || style="text-align:center;"| Semi-intensive || style="text-align:center;"| 158.8 (6-1/4) || style="text-align:center;"| 235 (9-1/4) || style="text-align:center;"| 127 (5) || style="text-align:center;"| 203.2 (8) || style="text-align:center;"| - || style="text-align:center;"| Consult Manufacturer || style="text-align:center;"| Consult Manufacturer
 
|-
 
| [[Manufacturers:Carlisle SynTec Systems Canada | Carlisle SynTec Systems Canada]] || style="text-align:center;"| [[Materials:Carlisle Intensive Roof Garden System | Carlisle Intensive Roof Garden System]] || style="text-align:center;"| Intensive || style="text-align:center;"| 235 (9-1/4) || style="text-align:center;"| No stated max. || style="text-align:center;"| 203.2 (8) || style="text-align:center;"| No stated max. || style="text-align:center;"| - || style="text-align:center;"| Consult Manufacturer || style="text-align:center;"| Consult Manufacturer
 
|-
 
| [[Manufacturers:Carlisle SynTec Systems Canada | Carlisle SynTec Systems Canada]] || style="text-align:center;"| [[Materials:Carlisle Roof Garden Extensive Stormwater Retention System  | Carlisle Roof Garden Extensive Stormwater Retention System ]] || style="text-align:center;"| Extensive || style="text-align:center;"| 140 (5-1/2) || style="text-align:center;"| 140 (5-1/2) || style="text-align:center;"| 101.6 (4) || style="text-align:center;"| 101.6 (4) || style="text-align:center;"| - || style="text-align:center;"| Consult Manufacturer || style="text-align:center;"| Consult Manufacturer
 
|-
 
| [[Manufacturers:Hydrotech Membrane Corporation | Hydrotech Membrane Corporation]] || style="text-align:center;"| [[Materials:Hydrotech Extensive Garden Roof Assembly | Hydrotech Extensive Garden Roof Assembly]] || style="text-align:center;"| Extensive || style="text-align:center;"| 101.6 (4) || style="text-align:center;"| 203.2 (7) || style="text-align:center;"| 76.2  (3) || style="text-align:center;"| 152.4 (6) || style="text-align:center;"| - || style="text-align:center;"| On file || style="text-align:center;"| On file
 
|-
 
| [[Manufacturers:Hydrotech Membrane Corporation | Hydrotech Membrane Corporation]] || style="text-align:center;"| [[Materials:Hydrotech Intensive Garden Roof Assembly | Hydrotech Intensive Garden Roof Assembly]] || style="text-align:center;"| Intensive || style="text-align:center;"| 355.6 (14) || style="text-align:center;"| 939.8 (37) || style="text-align:center;"| 304.8 (12) || style="text-align:center;"| 889 (35) || style="text-align:center;"| - || style="text-align:center;"| On file || style="text-align:center;"| On file
 
|-
 
| [[Manufacturers:Hydrotech Membrane Corporation | Hydrotech Membrane Corporation]] || style="text-align:center;"| [[Materials:Hydrotech Semi-intensive Garden Roof Assembly |Hydrotech Semi-intensive Garden Roof Assembly]] || style="text-align:center;"| Semi-intensive || style="text-align:center;"| 203.2 (8) || style="text-align:center;"| 355.6 (14) || style="text-align:center;"| 152.4 (6) || style="text-align:center;"| 304.8 (12) || style="text-align:center;"| - || style="text-align:center;"| On file || style="text-align:center;"| On file
 
|-
 
| [[Manufacturers:Next Level Stormwater Management | Next Level Stormwater Management]] || style="text-align:center;"| [[Materials:NLSM LiteN'Less | NLSM LiteN'Less]] || style="text-align:center;"| Extensive || style="text-align:center;"| 40.7 (1-5/8) || style="text-align:center;"| 64.0 (2-1/2) || style="text-align:center;"| 25.4 (1) || style="text-align:center;"| 25.4 (1) || style="text-align:center;"| - || style="text-align:center;"| Consult Manufacturer || style="text-align:center;"| On file
 
|-
 
| [[Manufacturers:Next Level Stormwater Management | Next Level Stormwater Management]] || style="text-align:center;"| [[Materials:NLSM LiteN'Less II | NLSM LiteN'Less II]] || style="text-align:center;"| Extensive || style="text-align:center;"| 30.7 (1-1/8) || style="text-align:center;"| 30.7 (1-1/8) || style="text-align:center;"| 20 (13/16) || style="text-align:center;"| 20 (13/16) || style="text-align:center;"| - || style="text-align:center;"| Consult Manufacturer || style="text-align:center;"| On file
 
|-
 
| [[Manufacturers:Next Level Stormwater Management | Next Level Stormwater Management]] || style="text-align:center;"| [[Materials:NLSM LiteN'Less III | NLSM LiteN'Less III]] || style="text-align:center;"| Extensive || style="text-align:center;"| 45.0 (1-13/16) || style="text-align:center;"| 62.0 (2-7/16) || style="text-align:center;"| 20 (13/16) || style="text-align:center;"| 20 (13/16) || style="text-align:center;"| - || style="text-align:center;"| Consult Manufacturer || style="text-align:center;"| On file
 
|-
 
| [[Manufacturers:Next Level Stormwater Management | Next Level Stormwater Management]] || style="text-align:center;"| [[Materials:NLSM TerraEXT | NLSM TerraEXT]] || style="text-align:center;"| Extensive || style="text-align:center;"| 113.0 (4-13/16) || style="text-align:center;"| 188 (7-13/16) || style="text-align:center;"| 95.0 (3-3/4) || style="text-align:center;"| 170 (6-11/16) || style="text-align:center;"| - || style="text-align:center;"| Consult Manufacturer || style="text-align:center;"| On file
 
|-
 
| [[Manufacturers:Next Level Stormwater Management | Next Level Stormwater Management]] || style="text-align:center;"| [[Materials:NLSM StormCap | NLSM StormCap]] || style="text-align:center;"| Extensive || style="text-align:center;"| 114 (4-1/2) || style="text-align:center;"| 264 (10-3/8) || style="text-align:center;"| 70 (2-3/4) || style="text-align:center;"| 170 (6-11/16) || style="text-align:center;"| - || style="text-align:center;"| Consult Manufacturer || style="text-align:center;"| On file
 
|-
 
| [[Manufacturers:Next Level Stormwater Management | Next Level Stormwater Management]] || style="text-align:center;"| [[Materials:NLSM StormCap Detain 3° | NLSM StormCap Detain 3°]] || style="text-align:center;"| Extensive || style="text-align:center;"| 114 (4-1/2) || style="text-align:center;"| 352 (13-7/8) || style="text-align:center;"| 70 (2-3/4) || style="text-align:center;"| 170 (6-11/16) || style="text-align:center;"| - || style="text-align:center;"| Consult Manufacturer || style="text-align:center;"| On file
 
|-
 
| [[Manufacturers:Next Level Stormwater Management | Next Level Stormwater Management]] || style="text-align:center;"| [[Materials:NLSM Eco-Grass | NLSM Eco-Grass]] || style="text-align:center;"| Semi-intensive || style="text-align:center;"| 188 (7-7/16) || style="text-align:center;"| 338 (13-5/16) || style="text-align:center;"| 170 (6-11/16) || style="text-align:center;"| 320 (12-9/16) || style="text-align:center;"| - || style="text-align:center;"| Consult Manufacturer || style="text-align:center;"| Consult Manufacturer
 
|-
 
| [[Manufacturers:Next Level Stormwater Management | Next Level Stormwater Management]] || style="text-align:center;"| [[Materials:NLSM Flora Garden | NLSM Flora Garden]] || style="text-align:center;"| Semi-intensive || style="text-align:center;"| 162 (6-3/8) || style="text-align:center;"| 312 (12-5/16) || style="text-align:center;"| 150.4 (6) || style="text-align:center;"| 304.8 (12) || style="text-align:center;"| - || style="text-align:center;"| Consult Manufacturer || style="text-align:center;"| Consult Manufacturer
 
|-
 
| [[Manufacturers:Soprema Inc. | Soprema Inc.]] || style="text-align:center;"| [[Materials:Soprema SOPRANATURE Extensive-Conventional Vegetated Roof | Soprema SOPRANATURE<sup>®</sup> Extensive-Conv. Vegetated Roof]] || style="text-align:center;"| Extensive || style="text-align:center;"| 85.85 (3-3/8) || style="text-align:center;"| 162 (6-3/8) || style="text-align:center;"| 76.2 (3) || style="text-align:center;"| 152.4 (6) || style="text-align:center;"| - || style="text-align:center;"| On file || style="text-align:center;"| On file
 
|-
 
| [[Manufacturers:Soprema Inc. | Soprema Inc.]] || style="text-align:center;"| [[Materials:Soprema SOPRANATURE Extensive-Inverted Vegetated Roof | Soprema SOPRANATURE<sup>®</sup> Extensive-Inverted Vegetated Roof]] || style="text-align:center;"| Extensive || style="text-align:center;"| 88.1 (3-6/16) || style="text-align:center;"| 164.3 (6-6/16) || style="text-align:center;"| 76.3 (3) || style="text-align:center;"| 152.4 (6) || style="text-align:center;"| - || style="text-align:center;"| On file || style="text-align:center;"| Consult Manufacturer
 
|-
 
| [[Manufacturers:Soprema Inc. | Soprema Inc.]] || style="text-align:center;"| [[Materials:Soprema SOPRANATURE Modular-Conventional Vegetated Roof | Soprema SOPRANATURE<sup>®</sup> Modular-Conv. Vegetated Roof]] || style="text-align:center;"| Extensive || style="text-align:center;"| 100.5 (3-15/16) || style="text-align:center;"| 100.5 (3-15/16) || style="text-align:center;"| 100 (3-7/8) || style="text-align:center;"| 100 (3-7/8) || style="text-align:center;"| - || style="text-align:center;"| On file || style="text-align:center;"| On file
 
|-
 
| [[Manufacturers:Soprema Inc. | Soprema Inc.]] || style="text-align:center;"| [[Materials:Soprema SOPRANATURE Modular-Inverted Vegetated Roof | Soprema SOPRANATURE<sup>®</sup> Modular-Inverted Vegetated Roof]] || style="text-align:center;"| Extensive || style="text-align:center;"| 100.5 (3-15/16) || style="text-align:center;"| 100.5 (3-15/16) || style="text-align:center;"| 100 (3-7/8) || style="text-align:center;"| 100 (3-7/8) || style="text-align:center;"| - || style="text-align:center;"| On file || style="text-align:center;"| Consult Manufacturer
 
|-
 
| [[Manufacturers:Soprema Inc. | Soprema Inc.]] || style="text-align:center;"| [[Materials:Soprema SOPRANATURE Semi-Intensive-Conventional (or Urban Agriculture) Vegetated Roof | Soprema SOPRANATURE<sup>®</sup> Semi-Intensive-Conv. Vegetated Roof]] || style="text-align:center;"| Semi-intensive || style="text-align:center;"| 162 (6-3/8) || style="text-align:center;"| 314.4 (12-3/8) || style="text-align:center;"| 152.4 (6) || style="text-align:center;"| 304.8 (12) || style="text-align:center;"| - || style="text-align:center;"| On file || style="text-align:center;"| Consult Manufacturer
 
|-
 
| [[Manufacturers:Soprema Inc. | Soprema Inc.]] || style="text-align:center;"| [[Materials:Soprema SOPRANATURE Semi-Intensive-Inverted (or Urban Agriculture) Vegetated Roof | Soprema SOPRANATURE<sup>®</sup> Semi-Intensive-Inverted Vegetated Roof]] || style="text-align:center;"| Semi-intensive || style="text-align:center;"| 164.3 (6-6/16) || style="text-align:center;"| 316.7 (12-6/16) || style="text-align:center;"| 152.4 (6) || style="text-align:center;"| 304.8 (12) || style="text-align:center;"| - || style="text-align:center;"| On file || style="text-align:center;"| Consult Manufacturer
 
|-
 
| [[Manufacturers:Soprema Inc. | Soprema Inc.]] || style="text-align:center;"| [[Materials:Soprema SOPRANATURE Intensive-Conventional Vegetated Roof | Soprema SOPRANATURE<sup>®</sup> Intensive-Conv. Vegetated Roof]] || style="text-align:center;"| Intensive/<br>Intensive (Cultivate) || style="text-align:center;"| 314.4 (12-3/8) || style="text-align:center;"| 314.4 (12-3/8) + || style="text-align:center;"| 304.8 (12) || style="text-align:center;"| 304.8 (12) + || style="text-align:center;"| - || style="text-align:center;"| On file || style="text-align:center;"| Consult Manufacturer
 
|-
 
| [[Manufacturers:Soprema Inc. | Soprema Inc.]] || style="text-align:center;"| [[Materials:Soprema SOPRANATURE Intensive-Inverted Vegetated Roof | Soprema SOPRANATURE<sup>®</sup> Intensive-Inverted Vegetated Roof]] || style="text-align:center;"| Intensive/<br>Intensive (Cultivate) || style="text-align:center;"| 361.7 (12-6/16) || style="text-align:center;"| 361.7 (12-6/16) + || style="text-align:center;"| 304.8 (12) || style="text-align:center;"| 304.8 (12) + || style="text-align:center;"| - || style="text-align:center;"| On file || style="text-align:center;"| Consult Manufacturer
 
|-
 
| [[Manufacturers:Soprema Inc. | Soprema Inc.]] || style="text-align:center;"| [[Materials:Soprema SKYWATER Ballasted-Conventional Hybrid Roof | Soprema SKYWATER<sup>®</sup> Ballasted-Conv. Hybrid Roof]] || style="text-align:center;"| All || style="text-align:center;"| 107.9 (4-1/4) || style="text-align:center;"| 336.5 (13-1/4) + || style="text-align:center;"| 76.3 (3) || style="text-align:center;"| 304.8 (12) + || style="text-align:center;"| - || style="text-align:center;"| On file || style="text-align:center;"| Consult Manufacturer
 
|-
 
| [[Manufacturers:Soprema Inc. | Soprema Inc.]] || style="text-align:center;"| [[Materials:Soprema SKYWATER Ballasted-Inverted Hybrid Roof | Soprema SKYWATER<sup>®</sup> Ballasted-Inverted Hybrid Roof]] || style="text-align:center;"| All || style="text-align:center;"| 107.9 (4-1/4) || style="text-align:center;"| 336.5 (13-1/4) + || style="text-align:center;"| 76.3 (3) || style="text-align:center;"| 304.8 (12) + || style="text-align:center;"| - || style="text-align:center;"| On file || style="text-align:center;"| Consult Manufacturer
 
|-
 
| [[Manufacturers:Soprema Inc. | Soprema Inc.]] || style="text-align:center;"| [[Materials:Soprema SKYWATER SOPRAFLOW CONTROL-Conventional Hybrid Roof | Soprema SKYWATER<sup>®</sup> SOPRAFLOW CONTROL-Conventional Hybrid Roof]] || style="text-align:center;"| All || style="text-align:center;"| 136.9 (5-3/8) || style="text-align:center;"| 265.2 (14-3/8) || style="text-align:center;"| 76.3 (3) || style="text-align:center;"| 304.8 (12) + || style="text-align:center;"| - || style="text-align:center;"| On file || style="text-align:center;"| Consult Manufacturer
 
|-
 
| [[Manufacturers:ZinCo Canada Inc. | ZinCo Canada Inc.]] || style="text-align:center;"| [[Materials:ZinCo Sedum Roof |ZinCo Sedum Roof]] || style="text-align:center;"| Extensive || style="text-align:center;"| 101.6 (4) || style="text-align:center;"| 127 (5) || style="text-align:center;"| 80 (3-1/8) || style="text-align:center;"| 80 (3-1/8) || style="text-align:center;"| - || style="text-align:center;"| Consult Manufacturer || style="text-align:center;"| On file
 
|-
 
| [[Manufacturers:ZinCo Canada Inc. | ZinCo Canada Inc.]] || style="text-align:center;"| [[Materials:ZinCo Sedum Roof XL | ZinCo Sedum Roof XL]] || style="text-align:center;"| Extensive || style="text-align:center;"| 114.3 (4-1/2) || style="text-align:center;"| 152.4 mm (6) || style="text-align:center;"| 80 (3-1/8) || style="text-align:center;"| 80 (3-1/8) || style="text-align:center;"| - || style="text-align:center;"| Consult Manufacturer || style="text-align:center;"| On file
 
|-
 
| [[Manufacturers:ZinCo Canada Inc. | ZinCo Canada Inc.]] || style="text-align:center;"| [[Materials:ZinCo Semi-Intensive Perennial Garden Assembly | ZinCo Semi-Intensive Perennial Garden Assembly]] || style="text-align:center;"| Semi-intensive || style="text-align:center;"| 185 (7-1/4) || style="text-align:center;"| 203.2 (8) || style="text-align:center;"| 152.4 mm (6) || style="text-align:center;"| 152.4 mm (6) || style="text-align:center;"| - || style="text-align:center;"| Consult Manufacturer || style="text-align:center;"| On file
 
|-
 
| [[Manufacturers:ZinCo Canada Inc. | ZinCo Canada Inc.]] || style="text-align:center;"| [[Materials:ZinCo Roof Garden Assembly | ZinCo Roof Garden Assembly]] || style="text-align:center;"| Intensive || style="text-align:center;"| 241.3 (9-1/2) || style="text-align:center;"| 260.35 (10-1/4) || style="text-align:center;"| 203.1 (8) || style="text-align:center;"| 203.1 (8) || style="text-align:center;"| - || style="text-align:center;"| Consult Manufacturer || style="text-align:center;"| On file
 
|-
 
| [[Manufacturers:ZinCo Canada Inc. | ZinCo Canada Inc.]] || style="text-align:center;"| [[Materials:ZinCo Blue Roof Assembly | ZinCo Blue Roof Assembly]] || style="text-align:center;"| Intensive || style="text-align:center;"| 215.9 (8-1/2) || style="text-align:center;"| 304.8 (12) || style="text-align:center;"| 101.6 (10) || style="text-align:center;"| 304.8 (12) || style="text-align:center;"| - || style="text-align:center;"| Consult Manufacturer || style="text-align:center;"| On file
 
|-
 
| [[Manufacturers:ZinCo Canada Inc. | ZinCo Canada Inc.]] || style="text-align:center;"| [[Materials:ZinCo Green Roof & Solar | ZinCo Green Roof & Solar]] || style="text-align:center;"| Intensive || style="text-align:center;"| 203.2 (8) || style="text-align:center;"| 203.2 (8) || style="text-align:center;"| 101.6 (4) || style="text-align:center;"| 101.6 (4) || style="text-align:center;"| - || style="text-align:center;"| Consult Manufacturer || style="text-align:center;"| On file
 
|-
 
|}
 
 
::<sup>‡</sup> Click on the Vegetated Roof System page for specified or optional vegetation profiles
 
::<sup>*</sup> Vegetated roof systems can be divided into three classic types: ''Extensive'', ''Semi-intensive'', and ''Intensive''.  Added to this are blue-green roofs, also referred to as "hybrid systems."  Refer to the Notes to the [https://rpm.rcabc.org/index.php?title=Notes_to_VRA_Standard Notes to the Standard for Vegetated Roofs] for an expanded treatment on these types.
 
::<sup>**</sup> Minimum system and growing media depths may vary.  For example, some manufacturers produce retention/detention mats in various thicknesses, to accommodate varying hydrological requirements.  This may affect the minimum thickness of a system.  Similarly, manufacturers may specify different minimum growing media depths depending on how the system will be used (i.e., deeper media if an intensive system is to be cultivated for rooftop agriculture).  Always refer to the '''system page''' for more information.
 
::<sup>†</sup> Saturated weight of a ''vegetated roof system'' depends on which components are used (since there are variabilities in many listed systems), but excludes the mature weight of ''vegetation'' as this is a variable the ''vegetated roof system manufacturer'' cannot control or predict.  It is therefore incumbent upon the ''Design Authority'' and structural engineer to factor these variables into load calculations.
 
 
 
 
</div>
 
</div>
 
<div class="col-md-12">
 
<div class="col-md-12">
Line 101: Line 17:
  
 
[[Main Page | <i class="fa fa-home fa"></i> Home]]
 
[[Main Page | <i class="fa fa-home fa"></i> Home]]
{{Tempate:RPM Page Footer with Copyright and Current Date}}
+
{{Template:RPM Page Footer with Copyright and Current Date}}
 
</div>
 
</div>

Latest revision as of 15:46, 29 November 2024

Division C - Accepted Materials


Vegetated ("Green") Roof Systems (VRS)

Vegetated Roof Systems
Click on a manufacturer's name to see the full list of their vegetated roof systems accepted for use in the RoofStar Guarantee Program. Click on the System Name to see the materials and documentation for the system.
To reset this page to its original view, click your browser refresh button.
VRS Supplier VR System Name * VRS
Type
Permissible
Roof Assembly
System
Min.
Depth
mm (in)
System
Max.
Depth
mm (in)
Media
Min.
Depth
mm (in)
Media
Max.
Depth
mm (in)
Carlisle SynTec Systems Canada Carlisle Extensive Roof Garden System Extensive All 101.6 (4) 158.8 (6-1/4) 70 (1-1/4) 127 (5)
Carlisle SynTec Systems Canada Carlisle Roof Garden Extensive Stormwater Retention System Extensive All 140 (5-1/2) 165.1 (6-1/2) 101.6 (4) 127 (5)
Carlisle SynTec Systems Canada Carlisle Semi-Intensive Roof Garden System Semi-Intensive PMRA 158.8 (6-1/4) 235 (9-1/4) 127 (5) 203.2 (8)
Carlisle SynTec Systems Canada Carlisle Intensive Roof Garden System Intensive PMRA 235 (9-1/4) None Stated 203.2 (8) None Stated
Hydrotech Membrane Corporation Hydrotech Extensive Garden Roof Assembly Extensive All 101.6 (4) 203.2 (7) 76.2 (3) 152.4 (6)
Hydrotech Membrane Corporation Hydrotech Semi-intensive Garden Roof Assembly Semi-Intensive PMRA 203.2 (8) 355.6 (14) 152.4 (6) 304.8 (12)
Hydrotech Membrane Corporation Hydrotech Intensive Garden Roof Assembly Intensive PMRA 355.6 (14) 939.8 (37) 304.8 (12) 889 (35)
Next Level Stormwater Management NLSM LiteN'Less Extensive All 40.7 (1-5/8) 64.0 (2-1/2) 25.4 (1) 25.4 (1)
Next Level Stormwater Management NLSM LiteN'Less II Extensive All 30.7 (1-1/8) 30.7 (1-1/8) 20 (13/16) 20 (13/16)
Next Level Stormwater Management NLSM LiteN'Less III Extensive All 45.0 (1-13/16) 62.0 (2-7/16) 20 (13/16) 20 (13/16)
Next Level Stormwater Management NLSM TerraEXT Extensive All 113.0 (4-13/16) 188 (7-13/16) 95.0 (3-3/4) 170 (6-11/16)
Next Level Stormwater Management NLSM StormCap Extensive All 114 (4-1/2) 264 (10-3/8) 70 (2-3/4) 170 (6-11/16)
Next Level Stormwater Management NLSM StormCap Detain 3° Extensive All 114 (4-1/2) 352 (13-7/8) 70 (2-3/4) 170 (6-11/16)
Next Level Stormwater Management NLSM Eco-Grass Semi-Intensive PMRA 188 (7-7/16) 338 (13-5/16) 170 (6-11/16) 320 (12-9/16)
Next Level Stormwater Management NLSM Flora Garden Semi-Intensive PMRA 162 (6-3/8) 312 (12-5/16) 150.4 (6) 304.8 (12)
Soprema Inc. SOPRANATURE® Extensive-Conv. Veg. Roof Extensive All 85.85 (3-3/8) 162 (6-3/8) 76.2 (3) 152.4 (6)
Soprema Inc. SOPRANATURE® Extensive-Inverted Veg. Roof Extensive All 88.1 (3-6/16) 164.3 (6-6/16) 76.3 (3) 152.4 (6)
Soprema Inc. SOPRANATURE® Modular-Conv. Veg. Roof Extensive All 100.5 (3-15/16) 100.5 (3-15/16) 100 (3-7/8) 100 (3-7/8)
Soprema Inc. SOPRANATURE® Modular-Inverted Veg. Roof Extensive All 100.5 (3-15/16) 100.5 (3-15/16) 100 (3-7/8) 100 (3-7/8)
Soprema Inc. SOPRANATURE® Semi-Intensive-Inverted Veg. Roof Semi-intensive PMRA 164.3 (6-6/16) 316.7 (12-6/16) 152.4 (6) 304.8 (12)
Soprema Inc. SOPRANATURE® Semi-Intensive-Conventional Veg. Roof** Semi-intensive PMRA** 164.3 (6-6/16) 316.7 (12-6/16) 152.4 (6) 304.8 (12)
Soprema Inc. SOPRANATURE® Intensive-Inverted Veg. Roof Intensive PMRA 361.7 (12-6/16) 361.7 (12-6/16) + 304.8 (12) 304.8 (12) +
Soprema Inc. SOPRANATURE® Intensive-Conventional Vegetated Roof** Intensive PMRA** 361.7 (12-6/16) 361.7 (12-6/16) + 304.8 (12) 304.8 (12) +
Soprema Inc. SKYWATER® Ballasted-Inverted Hybrid Roof Hybrid PMRA 107.9 (4-1/4) 336.5 (13-1/4) + 76.3 (3) 304.8 (12) +
Soprema Inc. SKYWATER® Ballasted-Conv. Hybrid Roof** Hybrid PMRA** 107.9 (4-1/4) 336.5 (13-1/4) + 76.3 (3) 304.8 (12) +
Soprema Inc. SKYWATER® SOPRAFLOW CONTROL** Hybrid PMRA** 136.9 (5-3/8) 265.2 (14-3/8) 76.3 (3) 304.8 (12) +
ZinCo Canada Inc. ZinCo Sedum Roof Extensive All 101.6 (4) 127 (5) 80 (3-1/8) 80 (3-1/8)
ZinCo Canada Inc. ZinCo Sedum Roof (Inverted) Extensive All 101.6 (4) 127 (5) 80 (3-1/8) 80 (3-1/8)
ZinCo Canada Inc. ZinCo Sedum Roof XL Extensive All 114.3 (4-1/2) 152.4 mm (6) 80 (3-1/8) 80 (3-1/8)
ZinCo Canada Inc. ZinCo Sedum Roof XL (Inverted) Extensive All 114.3 (4-1/2) 152.4 mm (6) 80 (3-1/8) 80 (3-1/8)
ZinCo Canada Inc. ZinCo Semi-Intensive Perennial Garden Assembly (Inverted) Semi-intensive PMRA 185 (7-1/4) 203.2 (8) 152.4 (6) 152.4 (6)
ZinCo Canada Inc. ZinCo Semi-Intensive Perennial Garden Assembly** Semi-intensive PMRA** 185 (7-1/4) 203.2 (8) 152.4 (6) 152.4 (6)
ZinCo Canada Inc. ZinCo Roof Garden Assembly (Inverted) Intensive PMRA 241.3 (9-1/2) 260.35 (10-1/4) 203.1 (8) 203.1 (8)
ZinCo Canada Inc. ZinCo Roof Garden Assembly** Intensive PMRA** 241.3 (9-1/2) 260.35 (10-1/4) 203.1 (8) 203.1 (8)
ZinCo Canada Inc. ZinCo Blue Roof Assembly (Inverted) Hybrid PMRA 215.9 (8-1/2) 304.8 (12) 101.6 (10) 304.8 (12)
ZinCo Canada Inc. ZinCo Blue Roof Assembly** Hybrid PMRA** 215.9 (8-1/2) 304.8 (12) 101.6 (10) 304.8 (12)
ZinCo Canada Inc. ZinCo Green Roof & Solar Extensive All 203.2 (8) 203.2 (8) 101.6 (4) 101.6 (4)
ZinCo Canada Inc. ZinCo Green Roof & Solar (Inverted)** Extensive PMRA** 203.2 (8) 203.2 (8) 101.6 (4) 101.6 (4)

Accepted Materials

Home

© RCABC 2025
RoofStarTM is a registered Trademark of the RCABC.
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.