;Accepted for application in: Vegetated Roof Systems
 
;Accepted for application in: Vegetated Roof Systems
 
;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]]
 
;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]]
;System Summary: description here, using <br>breaks
+
;System Summary: The '''Flora Garden''' system by Next Level Stormwater Management is designed to support native or non-native grasses, sedges, shrubs, perennials, aromatic herbs, berries, fruits, and vegetables in 150 mm or more of intensive engineered growing medium.  Growing medium is a proprietary blend of mineral and organic components. Depth can be increased and customized as required (adapted from the manufacturer's literature. See the link at right to the manufacturer's online resources page for more information).
<div style="text-align:left;">
+
<div style="text-align: left;">
[[File:Extensive VR System (sedum tile).jpg| left | 450 px| link=]]
+
[[File:Extensive VR System (banner).JPG| left | class=img-responsive | link=]]
 
</div>
 
</div>
 
</div>
 
</div>
 
<div class="col-md-6">
 
<div class="col-md-6">
 
;:
 
;:
;Manufacturer Online Resource: [Link Name]
+
;Manufacturer Online Resource: [https://www.nlsm.ca/systems-technical-info-2/intensive-systems/xf200-flora-garden/ Flora Garden System]
;System Depth: give range
+
;System Type: Intensive
;Growing Media Depth: give range
+
;System Depth: 162 mm (6-3/8") to 312 mm (12-5/16")
;Vegetation Profile: give manufacturer's profile name or description
+
;Growing Media Depth: 150.4 mm (6") to 304.8 mm (12")
;Suitable climate zones: give range or list zone numbers
+
;Vegetation Profile: native or non-native grasses, sedges, shrubs, perennials, aromatic herbs, berries, fruits, and vegetables (as specified by the Design Authority/Green Roof Design Professional. See Conditions and Limitations below)
;System Components:
+
;Suitable climate zones: All BC zones, subject to manufacturer's approval
:Component name (Click [link here] for the Technical Data Sheet PDF)
+
;System Components<sup>*</sup>: In the usual order, from top to bottom; click on link for Technical Data Sheet (TDS)
:Component name (Click [link here] for the Technical Data Sheet PDF)
+
:{| class="wikitable"
:Component name (Click [link here] for the Technical Data Sheet PDF)
+
|-
:Component name (Click [link here] for the Technical Data Sheet PDF)
+
|
:Component name (Click [link here] for the Technical Data Sheet PDF)
+
*'''Plant plugs''' (supplied by others*)
 +
*[https://rpm.rcabc.org/images/0/09/NLSM_NL630_Growing_Medium_TDS.pdf '''NL630 Growing Medium''']
 +
*[https://rpm.rcabc.org/images/f/fa/NLSM_NL400_Filter_Fabric_TDS.pdf '''NL400 Filter Fabric''']
 +
*[https://rpm.rcabc.org/images/c/cc/NLSM_NL310_Drainage_Board_TDS.pdf '''NL310 Drainage Board''']
 +
:'''XPS Insulation''' by roofing ''Contractor'' (Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]])
 +
*[https://rpm.rcabc.org/images/3/32/NLSM_NL120_Root_Barrier_TDS.pdf '''NL120 Root Barrier''']
 +
:'''Waterproofing Roof Assembly''' (membrane) by roofing ''Contractor''
 +
*[https://rpm.rcabc.org/images/9/96/NLSM_NL200_Edging_and_Accessories_TDS.pdf '''NL200 Edging & Accessories''']
 +
*'''NL210 Drain Box & Accessories'''
 +
*'''NL220 Penetration Box'''
 +
|}
 +
</div>
 +
<div class="col-md-12">
 +
<hr>
 +
<div class="col-md-6">
 +
 
 +
;<sup>†</sup>Guarantor's Notes: Systems labeled "Inverted" are designed for a ''protected membrane roof assembly'', also known as an inverted ''roof assembly''.
 +
 
 +
:While ''Semi-intensive'' and ''Intensive vegetated roof systems'' are limited to only ''protected membrane roofs'' (See the [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.2._Permitted_Vegetated_Roof_Systems Sentence 1.1.3.2.(5)] in the "RGC Standard for Vegetated Roofs"), some vegetated roof system manufacturers offer their systems for ''conventionally insulated roofs''.  To request a written Variance to the published limitation, follow the requirements in [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.6._Variances Article 1.1.3.6.].
 +
 
 +
</div>
 +
<div class="col-md-6">
  
 
;<sup>*</sup>Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements.  Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight.
 
;<sup>*</sup>Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements.  Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight.
  
 
:Also note that vegetation coverage under the '''''RoofStar Vegetated Roof Guarantee''''' applies only to ''extensive systems'' planted with mats or trays - see [https://rpm.rcabc.org/index.php?title=Guarantee Part 3] of Division A for more about coverage.
 
:Also note that vegetation coverage under the '''''RoofStar Vegetated Roof Guarantee''''' applies only to ''extensive systems'' planted with mats or trays - see [https://rpm.rcabc.org/index.php?title=Guarantee Part 3] of Division A for more about coverage.
 +
 
</div>
 
</div>
 
</div>
 
</div>

Latest revision as of 21:54, 2 December 2024



Division C - Accepted Materials
Group - Vegetated Roof Systems


NLSM Flora Garden
by Next Level Stormwater Management

System/Material Acceptance and Product Details


The information published in the RCABC Roofing Practices Manual and offered below does NOT represent a complete set of the manufacturer’s data or specifications, nor is this system and its various materials recommended or endorsed by the Guarantor. The preparation of a detailed specification is the responsibility of the Design Authority.

Vegetated Roof System Manufacturer
https://www.nlsm.ca/
Accepted for the RoofStar Guarantee Program
October 25, 2024
Accepted for application in
Vegetated Roof Systems
Acceptance Criteria
Refer to the RGC Standard for Vegetated Roofs
System Summary
The Flora Garden system by Next Level Stormwater Management is designed to support native or non-native grasses, sedges, shrubs, perennials, aromatic herbs, berries, fruits, and vegetables in 150 mm or more of intensive engineered growing medium. Growing medium is a proprietary blend of mineral and organic components. Depth can be increased and customized as required (adapted from the manufacturer's literature. See the link at right to the manufacturer's online resources page for more information).
Extensive VR System (banner).JPG
Manufacturer Online Resource
Flora Garden System
System Type
Intensive
System Depth
162 mm (6-3/8") to 312 mm (12-5/16")
Growing Media Depth
150.4 mm (6") to 304.8 mm (12")
Vegetation Profile
native or non-native grasses, sedges, shrubs, perennials, aromatic herbs, berries, fruits, and vegetables (as specified by the Design Authority/Green Roof Design Professional. See Conditions and Limitations below)
Suitable climate zones
All BC zones, subject to manufacturer's approval
System Components*
In the usual order, from top to bottom; click on link for Technical Data Sheet (TDS)
XPS Insulation by roofing Contractor (Refer to the RGC Standard for Vegetated Roofs)
Waterproofing Roof Assembly (membrane) by roofing Contractor

Guarantor's Notes
Systems labeled "Inverted" are designed for a protected membrane roof assembly, also known as an inverted roof assembly.
While Semi-intensive and Intensive vegetated roof systems are limited to only protected membrane roofs (See the Sentence 1.1.3.2.(5) in the "RGC Standard for Vegetated Roofs"), some vegetated roof system manufacturers offer their systems for conventionally insulated roofs. To request a written Variance to the published limitation, follow the requirements in Article 1.1.3.6..
*Conditions and Limitations
Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements. Consult with the vegetated roof system manufacturer for options and saturated system weight.
Also note that vegetation coverage under the RoofStar Vegetated Roof Guarantee applies only to extensive systems planted with mats or trays - see Part 3 of Division A for more about coverage.