Difference between revisions of "Materials:ZinCo Blue Roof Assembly (Inverted)"

Jump to: navigation, search

Difference between revisions of "Materials:ZinCo Blue Roof Assembly (Inverted)"

 
(4 intermediate revisions by the same user not shown)
Line 7: Line 7:
 
<big>Group - Vegetated Roof Systems</big>
 
<big>Group - Vegetated Roof Systems</big>
 
<hr>
 
<hr>
<big><big><big><big><big>ZinCo Blue Roof Assembly (Inverted)</big></big></big></big></big><br>
+
<big><big><big><big><big>ZinCo Blue Roof Assembly (Inverted<sup>†</sup>)</big></big></big></big></big><br>
 
<big><big><big>by ZinCo Canada Inc.</big></big></big><br>
 
<big><big><big>by ZinCo Canada Inc.</big></big></big><br>
 
{| class="wikitable"
 
{| class="wikitable"
Line 19: Line 19:
 
<div class="col-md-6">
 
<div class="col-md-6">
 
;:
 
;:
;'''Vegetated Roof System Manufacturer''': Name linked to website here
+
;'''Vegetated Roof System Manufacturer''': [https://www.zinco.ca/  '''ZinCo Canada Inc.''']
 
;Accepted for the ''RoofStar Guarantee Program'': October 25, 2024
 
;Accepted for the ''RoofStar Guarantee Program'': October 25, 2024
 
;Accepted for application in: Vegetated Roof Systems
 
;Accepted for application in: Vegetated Roof Systems
 
;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]]
 
;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]]
;System Summary: description here, using <br>breaks
+
;System Summary: ZinCo's custom roof systems are designed to capture stormwater and release it in a sustainable fashion.  Features include:
 +
:*Maximum water retention with no negative impact on the green roof vegetation
 +
:*Option for timed water release
 +
:*Compliant with most Canadian municipal codes
 +
:*Addition of up to 55 L/m2 retention capacity
 
<div style="text-align: left;">
 
<div style="text-align: left;">
[[File:Extensive VR System (sedum tile).jpg| left | 450 px| link=]]
+
[[File:Extensive VR System (banner).JPG| left | class=img-responsive | link=]]
 
</div>
 
</div>
 
</div>
 
</div>
 
<div class="col-md-6">
 
<div class="col-md-6">
 
;:
 
;:
;Manufacturer Online Resource: [Link Name]
+
;Manufacturer Online Resource: [https://www.zinco.ca/stormwater-management-roof ZinCo Blue Roof Assembly]
;System Depth: give range
+
;System Type: "Hybrid" (Blue-Green); see [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.2._Permitted_Vegetated_Roof_Systems Sentences 1.1.3.2.(6) through (8)] in the "RGC Standard for Vegetated Roofs".
;Growing Media Depth: give range
+
;System Depth: 215.9 mm (8-1/2") to 304.8 mm (12")
;Vegetation Profile: give manufacturer's profile name or description
+
;Growing Media Depth: 101.6 mm (10") to 304.8 mm (12")
;Suitable climate zones: give range or list zone numbers
+
;Vegetation Profile: Trees, Shrubs, Perennials, Grasses, Herbacious, Sedums
;System Components:
+
;Suitable climate zones: All BC zones, subject to manufacturer's approval
:Component name (Click [link here] for the Technical Data Sheet PDF)
+
;System Components<sup>*</sup>: In the usual order, from top to bottom; click on link for Technical Data Sheet (TDS)
:Component name (Click [link here] for the Technical Data Sheet PDF)
+
:{| class="wikitable"
:Component name (Click [link here] for the Technical Data Sheet PDF)
+
|-
:Component name (Click [link here] for the Technical Data Sheet PDF)
+
|
:Component name (Click [link here] for the Technical Data Sheet PDF)
+
*'''Perennials-Grasses-Herbacious-Sedums''' (See pre-grown vegetation by ZinCo Canada) or as specified by the ''Design Authority''/''Green Roof Design Professional'' (See '''Conditions and Limitations''' below)
 +
*[https://rpm.rcabc.org/images/8/86/ZinCo_System_Growing_Medium_%28ZinCo_Blend-E%29_TDS.pdf '''Blend-E Growing Medium'''] or [https://rpm.rcabc.org/images/e/e3/ZinCo_System_Growing_Medium_%28ZinCo_Blend_I%29_TDS.pdf '''Growing Medium Blend-I''']
 +
*[https://rpm.rcabc.org/images/9/91/ZinCo_Filter_Sheet_SF_TDS.pdf '''Filter Sheet SF''']
 +
**[https://rpm.rcabc.org/images/a/a6/ZinCo_Filter_Sheet_PV_TDS.pdf '''Filter Sheet PV'''] (Alternate)
 +
*'''Floradrain''':
 +
**[https://rpm.rcabc.org/images/c/c0/ZinCo_Floradrain_FD60_TDS.pdf '''Floradrain FD60-E'''],
 +
**[https://rpm.rcabc.org/images/6/62/ZinCo_Floradrain_FD40-E_TDS.pdf '''Floradrain FD40-E'''], or
 +
**[https://rpm.rcabc.org/images/7/75/ZinCo_Floradrain_FD25-E_TDS.pdf '''Floradrain FD25-E''']
 +
*[https://rpm.rcabc.org/images/9/91/ZinCo_RetentionSpacer_RSX-Series_%2865-80-100-150%29_TDS.pdf '''RSX150 Retention Spacer''']
 +
**[https://rpm.rcabc.org/images/9/91/ZinCo_RetentionSpacer_RSX-Series_%2865-80-100-150%29_TDS.pdf '''RSX Series (65-80-100) Retention Spacer'''] (Alternate)
 +
**[https://rpm.rcabc.org/images/2/20/ZinCo_Retention_Spacer_RSX_Series_%2870-120-170%29_TDS.pdf '''RSX Series (70-120-170) Retention Spacer'''] (Alternate)
 +
*[https://rpm.rcabc.org/images/7/73/ZinCo_Filter_Sheet_TG_TDS.pdf '''Filter Sheet TG''']
 +
*[https://rpm.rcabc.org/images/4/40/ZinCo_Separation_Membrane_TGV21_TDS.pdf '''TGV 21 Diffusion Membrane''']
 +
:'''XPS Insulation''' by roofing ''Contractor'' (Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]])
 +
*[https://rpm.rcabc.org/images/0/09/ZinCo_Root_Barrier_WSF40_TDS.pdf '''Root Barrier WSF40''']
 +
**[https://rpm.rcabc.org/images/2/2e/ZinCo_Root_Barrier_WSB100-PO_TDS.pdf '''Root Barrier WSB100-PO'''] (alternate root barrier)
 +
:'''Waterproofing Roof Assembly''' (membrane) by roofing ''Contractor''
 +
 
 +
*[https://rpm.rcabc.org/images/c/c4/ZinCo_Eaves_Profile_DP300_TDS.pdf '''Edging Profile DP300'''], [https://rpm.rcabc.org/images/d/df/ZinCo_Eaves_Profile_DP250_TDS.pdf '''Edging Profile DP250'''], or [https://rpm.rcabc.org/images/3/3f/ZinCo_Eaves_Profile_DP225_TDS.pdf '''Edging Profile DP225''']
 +
*[https://rpm.rcabc.org/images/9/92/ZinCo_Inspection_Chamber_KS30-E_Stainless_steel_TDS.pdf '''Inspection Chamber KS30SS''']
 +
|}
 +
</div>
 +
<div class="col-md-12">
 +
<hr>
 +
<div class="col-md-6">
 +
 
 +
;<sup>†</sup>Guarantor's Notes: Systems labeled "Inverted" are designed for a ''protected membrane roof assembly'', also known as an inverted ''roof assembly''.
 +
 
 +
:While ''Semi-intensive'' and ''Intensive vegetated roof systems'' are limited to only ''protected membrane roofs'' (See the [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.2._Permitted_Vegetated_Roof_Systems Sentence 1.1.3.2.(5)] in the "RGC Standard for Vegetated Roofs"), some vegetated roof system manufacturers offer their systems for ''conventionally insulated roofs''.  To request a written Variance to the published limitation, follow the requirements in [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.6._Variances Article 1.1.3.6.].
 +
 
 +
</div>
 +
<div class="col-md-6">
  
 
;<sup>*</sup>Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements.  Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight.
 
;<sup>*</sup>Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements.  Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight.
  
 
:Also note that vegetation coverage under the '''''RoofStar Vegetated Roof Guarantee''''' applies only to ''extensive systems'' planted with mats or trays - see [https://rpm.rcabc.org/index.php?title=Guarantee Part 3] of Division A for more about coverage.
 
:Also note that vegetation coverage under the '''''RoofStar Vegetated Roof Guarantee''''' applies only to ''extensive systems'' planted with mats or trays - see [https://rpm.rcabc.org/index.php?title=Guarantee Part 3] of Division A for more about coverage.
 +
 
</div>
 
</div>
 
</div>
 
</div>

Latest revision as of 23:21, 2 December 2024



Division C - Accepted Materials
Group - Vegetated Roof Systems


ZinCo Blue Roof Assembly (Inverted)
by ZinCo Canada Inc.

System/Material Acceptance and Product Details


The information published in the RCABC Roofing Practices Manual and offered below does NOT represent a complete set of the manufacturer’s data or specifications, nor is this system and its various materials recommended or endorsed by the Guarantor. The preparation of a detailed specification is the responsibility of the Design Authority.

Vegetated Roof System Manufacturer
ZinCo Canada Inc.
Accepted for the RoofStar Guarantee Program
October 25, 2024
Accepted for application in
Vegetated Roof Systems
Acceptance Criteria
Refer to the RGC Standard for Vegetated Roofs
System Summary
ZinCo's custom roof systems are designed to capture stormwater and release it in a sustainable fashion. Features include:
  • Maximum water retention with no negative impact on the green roof vegetation
  • Option for timed water release
  • Compliant with most Canadian municipal codes
  • Addition of up to 55 L/m2 retention capacity
Extensive VR System (banner).JPG
Manufacturer Online Resource
ZinCo Blue Roof Assembly
System Type
"Hybrid" (Blue-Green); see Sentences 1.1.3.2.(6) through (8) in the "RGC Standard for Vegetated Roofs".
System Depth
215.9 mm (8-1/2") to 304.8 mm (12")
Growing Media Depth
101.6 mm (10") to 304.8 mm (12")
Vegetation Profile
Trees, Shrubs, Perennials, Grasses, Herbacious, Sedums
Suitable climate zones
All BC zones, subject to manufacturer's approval
System Components*
In the usual order, from top to bottom; click on link for Technical Data Sheet (TDS)
XPS Insulation by roofing Contractor (Refer to the RGC Standard for Vegetated Roofs)
Waterproofing Roof Assembly (membrane) by roofing Contractor

Guarantor's Notes
Systems labeled "Inverted" are designed for a protected membrane roof assembly, also known as an inverted roof assembly.
While Semi-intensive and Intensive vegetated roof systems are limited to only protected membrane roofs (See the Sentence 1.1.3.2.(5) in the "RGC Standard for Vegetated Roofs"), some vegetated roof system manufacturers offer their systems for conventionally insulated roofs. To request a written Variance to the published limitation, follow the requirements in Article 1.1.3.6..
*Conditions and Limitations
Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements. Consult with the vegetated roof system manufacturer for options and saturated system weight.
Also note that vegetation coverage under the RoofStar Vegetated Roof Guarantee applies only to extensive systems planted with mats or trays - see Part 3 of Division A for more about coverage.



Back to Accepted Materials