Line 23: | Line 23: | ||
;Accepted for application in: Vegetated Roof Systems | ;Accepted for application in: Vegetated Roof Systems | ||
;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]] | ;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]] | ||
− | ;System Summary: | + | ;System Summary: ZinCo's custom roof systems are designed to capture stormwater and release it in a sustainable fashion. Features include: |
− | + | :*Maximum water retention with no negative impact on the green roof vegetation | |
− | + | :*Option for timed water release | |
− | + | :*Compliant with most Canadian municipal codes | |
+ | :*Addition of up to 55 L/m2 retention capacity | ||
<div style="text-align: left;"> | <div style="text-align: left;"> | ||
− | [[File:Extensive VR System ( | + | [[File:Extensive VR System (banner).JPG| left | class=img-responsive | link=]] |
</div> | </div> | ||
</div> | </div> | ||
<div class="col-md-6"> | <div class="col-md-6"> | ||
;: | ;: | ||
− | ;Manufacturer Online Resource: | + | ;Manufacturer Online Resource: [https://www.zinco.ca/stormwater-management-roof ZinCo Blue Roof Assembly] |
+ | ;System Type: "Hybrid" (Blue-Green); see [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.2._Permitted_Vegetated_Roof_Systems Sentences 1.1.3.2.(6) through (8)] in the "RGC Standard for Vegetated Roofs". | ||
;System Depth: 215.9 mm (8-1/2") to 304.8 mm (12") | ;System Depth: 215.9 mm (8-1/2") to 304.8 mm (12") | ||
;Growing Media Depth: 101.6 mm (10") to 304.8 mm (12") | ;Growing Media Depth: 101.6 mm (10") to 304.8 mm (12") | ||
Line 45: | Line 47: | ||
*[https://rpm.rcabc.org/images/8/86/ZinCo_System_Growing_Medium_%28ZinCo_Blend-E%29_TDS.pdf '''Blend-E Growing Medium'''] or [https://rpm.rcabc.org/images/e/e3/ZinCo_System_Growing_Medium_%28ZinCo_Blend_I%29_TDS.pdf '''Growing Medium Blend-I'''] | *[https://rpm.rcabc.org/images/8/86/ZinCo_System_Growing_Medium_%28ZinCo_Blend-E%29_TDS.pdf '''Blend-E Growing Medium'''] or [https://rpm.rcabc.org/images/e/e3/ZinCo_System_Growing_Medium_%28ZinCo_Blend_I%29_TDS.pdf '''Growing Medium Blend-I'''] | ||
*[https://rpm.rcabc.org/images/9/91/ZinCo_Filter_Sheet_SF_TDS.pdf '''Filter Sheet SF'''] | *[https://rpm.rcabc.org/images/9/91/ZinCo_Filter_Sheet_SF_TDS.pdf '''Filter Sheet SF'''] | ||
+ | **[https://rpm.rcabc.org/images/a/a6/ZinCo_Filter_Sheet_PV_TDS.pdf '''Filter Sheet PV'''] (Alternate) | ||
*'''Floradrain''': | *'''Floradrain''': | ||
**[https://rpm.rcabc.org/images/c/c0/ZinCo_Floradrain_FD60_TDS.pdf '''Floradrain FD60-E'''], | **[https://rpm.rcabc.org/images/c/c0/ZinCo_Floradrain_FD60_TDS.pdf '''Floradrain FD60-E'''], | ||
**[https://rpm.rcabc.org/images/6/62/ZinCo_Floradrain_FD40-E_TDS.pdf '''Floradrain FD40-E'''], or | **[https://rpm.rcabc.org/images/6/62/ZinCo_Floradrain_FD40-E_TDS.pdf '''Floradrain FD40-E'''], or | ||
**[https://rpm.rcabc.org/images/7/75/ZinCo_Floradrain_FD25-E_TDS.pdf '''Floradrain FD25-E'''] | **[https://rpm.rcabc.org/images/7/75/ZinCo_Floradrain_FD25-E_TDS.pdf '''Floradrain FD25-E'''] | ||
− | |||
*[https://rpm.rcabc.org/images/9/91/ZinCo_RetentionSpacer_RSX-Series_%2865-80-100-150%29_TDS.pdf '''RSX150 Retention Spacer'''] | *[https://rpm.rcabc.org/images/9/91/ZinCo_RetentionSpacer_RSX-Series_%2865-80-100-150%29_TDS.pdf '''RSX150 Retention Spacer'''] | ||
**[https://rpm.rcabc.org/images/9/91/ZinCo_RetentionSpacer_RSX-Series_%2865-80-100-150%29_TDS.pdf '''RSX Series (65-80-100) Retention Spacer'''] (Alternate) | **[https://rpm.rcabc.org/images/9/91/ZinCo_RetentionSpacer_RSX-Series_%2865-80-100-150%29_TDS.pdf '''RSX Series (65-80-100) Retention Spacer'''] (Alternate) | ||
Line 60: | Line 62: | ||
:'''Waterproofing Roof Assembly''' (membrane) by roofing ''Contractor'' | :'''Waterproofing Roof Assembly''' (membrane) by roofing ''Contractor'' | ||
− | *[https://rpm.rcabc.org/images/c/c4/ZinCo_Eaves_Profile_DP300_TDS.pdf '''Edging Profile DP300'''], | + | *[https://rpm.rcabc.org/images/c/c4/ZinCo_Eaves_Profile_DP300_TDS.pdf '''Edging Profile DP300'''], [https://rpm.rcabc.org/images/d/df/ZinCo_Eaves_Profile_DP250_TDS.pdf '''Edging Profile DP250'''], or [https://rpm.rcabc.org/images/3/3f/ZinCo_Eaves_Profile_DP225_TDS.pdf '''Edging Profile DP225'''] |
*[https://rpm.rcabc.org/images/9/92/ZinCo_Inspection_Chamber_KS30-E_Stainless_steel_TDS.pdf '''Inspection Chamber KS30SS'''] | *[https://rpm.rcabc.org/images/9/92/ZinCo_Inspection_Chamber_KS30-E_Stainless_steel_TDS.pdf '''Inspection Chamber KS30SS'''] | ||
|} | |} | ||
+ | </div> | ||
+ | <div class="col-md-12"> | ||
+ | <hr> | ||
+ | <div class="col-md-6"> | ||
+ | |||
+ | ;<sup>†</sup>Guarantor's Notes: Systems labeled "Inverted" are designed for a ''protected membrane roof assembly'', also known as an inverted ''roof assembly''. | ||
+ | |||
+ | :While ''Semi-intensive'' and ''Intensive vegetated roof systems'' are limited to only ''protected membrane roofs'' (See the [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.2._Permitted_Vegetated_Roof_Systems Sentence 1.1.3.2.(5)] in the "RGC Standard for Vegetated Roofs"), some vegetated roof system manufacturers offer their systems for ''conventionally insulated roofs''. To request a written Variance to the published limitation, follow the requirements in [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.6._Variances Article 1.1.3.6.]. | ||
+ | |||
+ | </div> | ||
+ | <div class="col-md-6"> | ||
;<sup>*</sup>Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements. Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight. | ;<sup>*</sup>Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements. Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight. | ||
:Also note that vegetation coverage under the '''''RoofStar Vegetated Roof Guarantee''''' applies only to ''extensive systems'' planted with mats or trays - see [https://rpm.rcabc.org/index.php?title=Guarantee Part 3] of Division A for more about coverage. | :Also note that vegetation coverage under the '''''RoofStar Vegetated Roof Guarantee''''' applies only to ''extensive systems'' planted with mats or trays - see [https://rpm.rcabc.org/index.php?title=Guarantee Part 3] of Division A for more about coverage. | ||
+ | |||
</div> | </div> | ||
</div> | </div> |
Latest revision as of 23:21, 2 December 2024
Division C - Accepted Materials
Group - Vegetated Roof Systems
ZinCo Blue Roof Assembly (Inverted†)
by ZinCo Canada Inc.
System/Material Acceptance and Product Details
| |
|