Difference between revisions of "Materials:ZinCo Blue Roof Assembly (Inverted)"

Jump to: navigation, search

Difference between revisions of "Materials:ZinCo Blue Roof Assembly (Inverted)"

 
(2 intermediate revisions by the same user not shown)
Line 23: Line 23:
 
;Accepted for application in: Vegetated Roof Systems
 
;Accepted for application in: Vegetated Roof Systems
 
;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]]
 
;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]]
;System Summary: description here, using <br>breaks
+
;System Summary:  ZinCo's custom roof systems are designed to capture stormwater and release it in a sustainable fashionFeatures include:
<sup>†</sup>Systems labeled "Inverted" are designed for a ''protected membrane roof assembly'', also known as an inverted ''roof assembly''. While ''Semi-intensive'' and ''Intensive vegetated roof systems'' are limited to only ''protected membrane roofs'' (See the [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.2._Permitted_Vegetated_Roof_Systems Sentence 1.1.3.2.(5)] in the "RGC Standard for Vegetated Roofs"), some vegetated roof system manufacturers offer their systems for ''conventionally insulated roofs''To request a written Variance to the published limitation, follow the requirements in [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.6._Variances Article 1.1.3.6.].
+
:*Maximum water retention with no negative impact on the green roof vegetation
 
+
:*Option for timed water release
Note that the supporting ''roof assembly'' of vegetated roof systems designed to hold free-standing water must conform to the requirements in Sentences 1.1.3.2.(6) and (7).
+
:*Compliant with most Canadian municipal codes
 +
:*Addition of up to 55 L/m2 retention capacity
 
<div style="text-align: left;">
 
<div style="text-align: left;">
[[File:Extensive VR System (sedum tile).jpg| left | 450 px| link=]]
+
[[File:Extensive VR System (banner).JPG| left | class=img-responsive | link=]]
 
</div>
 
</div>
 
</div>
 
</div>
 
<div class="col-md-6">
 
<div class="col-md-6">
 
;:
 
;:
;Manufacturer Online Resource:
+
;Manufacturer Online Resource: [https://www.zinco.ca/stormwater-management-roof ZinCo Blue Roof Assembly]
 +
;System Type: "Hybrid" (Blue-Green); see [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.2._Permitted_Vegetated_Roof_Systems Sentences 1.1.3.2.(6) through (8)] in the "RGC Standard for Vegetated Roofs".
 
;System Depth: 215.9 mm (8-1/2") to 304.8 mm (12")
 
;System Depth: 215.9 mm (8-1/2") to 304.8 mm (12")
 
;Growing Media Depth: 101.6 mm (10") to 304.8 mm (12")
 
;Growing Media Depth: 101.6 mm (10") to 304.8 mm (12")
Line 45: Line 47:
 
*[https://rpm.rcabc.org/images/8/86/ZinCo_System_Growing_Medium_%28ZinCo_Blend-E%29_TDS.pdf '''Blend-E Growing Medium'''] or [https://rpm.rcabc.org/images/e/e3/ZinCo_System_Growing_Medium_%28ZinCo_Blend_I%29_TDS.pdf '''Growing Medium Blend-I''']
 
*[https://rpm.rcabc.org/images/8/86/ZinCo_System_Growing_Medium_%28ZinCo_Blend-E%29_TDS.pdf '''Blend-E Growing Medium'''] or [https://rpm.rcabc.org/images/e/e3/ZinCo_System_Growing_Medium_%28ZinCo_Blend_I%29_TDS.pdf '''Growing Medium Blend-I''']
 
*[https://rpm.rcabc.org/images/9/91/ZinCo_Filter_Sheet_SF_TDS.pdf '''Filter Sheet SF''']
 
*[https://rpm.rcabc.org/images/9/91/ZinCo_Filter_Sheet_SF_TDS.pdf '''Filter Sheet SF''']
 +
**[https://rpm.rcabc.org/images/a/a6/ZinCo_Filter_Sheet_PV_TDS.pdf '''Filter Sheet PV'''] (Alternate)
 
*'''Floradrain''':
 
*'''Floradrain''':
 
**[https://rpm.rcabc.org/images/c/c0/ZinCo_Floradrain_FD60_TDS.pdf '''Floradrain FD60-E'''],
 
**[https://rpm.rcabc.org/images/c/c0/ZinCo_Floradrain_FD60_TDS.pdf '''Floradrain FD60-E'''],
 
**[https://rpm.rcabc.org/images/6/62/ZinCo_Floradrain_FD40-E_TDS.pdf '''Floradrain FD40-E'''], or
 
**[https://rpm.rcabc.org/images/6/62/ZinCo_Floradrain_FD40-E_TDS.pdf '''Floradrain FD40-E'''], or
 
**[https://rpm.rcabc.org/images/7/75/ZinCo_Floradrain_FD25-E_TDS.pdf '''Floradrain FD25-E''']
 
**[https://rpm.rcabc.org/images/7/75/ZinCo_Floradrain_FD25-E_TDS.pdf '''Floradrain FD25-E''']
**[https://rpm.rcabc.org/images/a/a6/ZinCo_Filter_Sheet_PV_TDS.pdf '''Filter Sheet PV'''] (Alternate)
 
 
*[https://rpm.rcabc.org/images/9/91/ZinCo_RetentionSpacer_RSX-Series_%2865-80-100-150%29_TDS.pdf '''RSX150 Retention Spacer''']
 
*[https://rpm.rcabc.org/images/9/91/ZinCo_RetentionSpacer_RSX-Series_%2865-80-100-150%29_TDS.pdf '''RSX150 Retention Spacer''']
 
**[https://rpm.rcabc.org/images/9/91/ZinCo_RetentionSpacer_RSX-Series_%2865-80-100-150%29_TDS.pdf '''RSX Series (65-80-100) Retention Spacer'''] (Alternate)
 
**[https://rpm.rcabc.org/images/9/91/ZinCo_RetentionSpacer_RSX-Series_%2865-80-100-150%29_TDS.pdf '''RSX Series (65-80-100) Retention Spacer'''] (Alternate)
Line 60: Line 62:
 
:'''Waterproofing Roof Assembly''' (membrane) by roofing ''Contractor''
 
:'''Waterproofing Roof Assembly''' (membrane) by roofing ''Contractor''
  
*[https://rpm.rcabc.org/images/c/c4/ZinCo_Eaves_Profile_DP300_TDS.pdf '''Edging Profile DP300'''], *[https://rpm.rcabc.org/images/d/df/ZinCo_Eaves_Profile_DP250_TDS.pdf '''Edging Profile DP250'''], or *[https://rpm.rcabc.org/images/3/3f/ZinCo_Eaves_Profile_DP225_TDS.pdf '''Edging Profile DP225''']
+
*[https://rpm.rcabc.org/images/c/c4/ZinCo_Eaves_Profile_DP300_TDS.pdf '''Edging Profile DP300'''], [https://rpm.rcabc.org/images/d/df/ZinCo_Eaves_Profile_DP250_TDS.pdf '''Edging Profile DP250'''], or [https://rpm.rcabc.org/images/3/3f/ZinCo_Eaves_Profile_DP225_TDS.pdf '''Edging Profile DP225''']
 
*[https://rpm.rcabc.org/images/9/92/ZinCo_Inspection_Chamber_KS30-E_Stainless_steel_TDS.pdf '''Inspection Chamber KS30SS''']
 
*[https://rpm.rcabc.org/images/9/92/ZinCo_Inspection_Chamber_KS30-E_Stainless_steel_TDS.pdf '''Inspection Chamber KS30SS''']
 
|}
 
|}
 +
</div>
 +
<div class="col-md-12">
 +
<hr>
 +
<div class="col-md-6">
 +
 +
;<sup>†</sup>Guarantor's Notes: Systems labeled "Inverted" are designed for a ''protected membrane roof assembly'', also known as an inverted ''roof assembly''.
 +
 +
:While ''Semi-intensive'' and ''Intensive vegetated roof systems'' are limited to only ''protected membrane roofs'' (See the [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.2._Permitted_Vegetated_Roof_Systems Sentence 1.1.3.2.(5)] in the "RGC Standard for Vegetated Roofs"), some vegetated roof system manufacturers offer their systems for ''conventionally insulated roofs''.  To request a written Variance to the published limitation, follow the requirements in [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.6._Variances Article 1.1.3.6.].
 +
 +
</div>
 +
<div class="col-md-6">
  
 
;<sup>*</sup>Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements.  Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight.
 
;<sup>*</sup>Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements.  Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight.
  
 
:Also note that vegetation coverage under the '''''RoofStar Vegetated Roof Guarantee''''' applies only to ''extensive systems'' planted with mats or trays - see [https://rpm.rcabc.org/index.php?title=Guarantee Part 3] of Division A for more about coverage.
 
:Also note that vegetation coverage under the '''''RoofStar Vegetated Roof Guarantee''''' applies only to ''extensive systems'' planted with mats or trays - see [https://rpm.rcabc.org/index.php?title=Guarantee Part 3] of Division A for more about coverage.
 +
 
</div>
 
</div>
 
</div>
 
</div>

Latest revision as of 23:21, 2 December 2024



Division C - Accepted Materials
Group - Vegetated Roof Systems


ZinCo Blue Roof Assembly (Inverted)
by ZinCo Canada Inc.

System/Material Acceptance and Product Details


The information published in the RCABC Roofing Practices Manual and offered below does NOT represent a complete set of the manufacturer’s data or specifications, nor is this system and its various materials recommended or endorsed by the Guarantor. The preparation of a detailed specification is the responsibility of the Design Authority.

Vegetated Roof System Manufacturer
ZinCo Canada Inc.
Accepted for the RoofStar Guarantee Program
October 25, 2024
Accepted for application in
Vegetated Roof Systems
Acceptance Criteria
Refer to the RGC Standard for Vegetated Roofs
System Summary
ZinCo's custom roof systems are designed to capture stormwater and release it in a sustainable fashion. Features include:
  • Maximum water retention with no negative impact on the green roof vegetation
  • Option for timed water release
  • Compliant with most Canadian municipal codes
  • Addition of up to 55 L/m2 retention capacity
Extensive VR System (banner).JPG
Manufacturer Online Resource
ZinCo Blue Roof Assembly
System Type
"Hybrid" (Blue-Green); see Sentences 1.1.3.2.(6) through (8) in the "RGC Standard for Vegetated Roofs".
System Depth
215.9 mm (8-1/2") to 304.8 mm (12")
Growing Media Depth
101.6 mm (10") to 304.8 mm (12")
Vegetation Profile
Trees, Shrubs, Perennials, Grasses, Herbacious, Sedums
Suitable climate zones
All BC zones, subject to manufacturer's approval
System Components*
In the usual order, from top to bottom; click on link for Technical Data Sheet (TDS)
XPS Insulation by roofing Contractor (Refer to the RGC Standard for Vegetated Roofs)
Waterproofing Roof Assembly (membrane) by roofing Contractor

Guarantor's Notes
Systems labeled "Inverted" are designed for a protected membrane roof assembly, also known as an inverted roof assembly.
While Semi-intensive and Intensive vegetated roof systems are limited to only protected membrane roofs (See the Sentence 1.1.3.2.(5) in the "RGC Standard for Vegetated Roofs"), some vegetated roof system manufacturers offer their systems for conventionally insulated roofs. To request a written Variance to the published limitation, follow the requirements in Article 1.1.3.6..
*Conditions and Limitations
Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements. Consult with the vegetated roof system manufacturer for options and saturated system weight.
Also note that vegetation coverage under the RoofStar Vegetated Roof Guarantee applies only to extensive systems planted with mats or trays - see Part 3 of Division A for more about coverage.



Back to Accepted Materials

Home