;Accepted for application in: Vegetated Roof Systems | ;Accepted for application in: Vegetated Roof Systems | ||
;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]] | ;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]] | ||
− | ;System Summary: '''Carlisle Extensive Roof Garden System''', also known as a "shallow" green roof, is a built-in-place system with a media depth ranging from 7 cm (2.75 in) to 12.7 cm (5 in). ''Extensive green roofs'' are the most commonly specified type due to their lightweight design and cost-effectiveness, making them ideal for retrofit applications. | + | ;System Summary: '''Carlisle Extensive Roof Garden System''', also known as a "shallow" green roof, is a built-in-place system with a media depth ranging from 7 cm (2.75 in) to 12.7 cm (5 in). ''Extensive green roofs'' are the most commonly specified type due to their lightweight design and cost-effectiveness, making them ideal for retrofit applications. The shallower ''growing media'' depth is well-suited for low-growing, drought-tolerant vegetation like sedum, which requires minimal maintenance compared to other green roof types (Adapted from the manufacturer's summary. See the link at right to the manufacturer's online resources page for more information). |
− | |||
− | |||
<div style="text-align: left;"> | <div style="text-align: left;"> | ||
− | [[File:Extensive VR System ( | + | [[File:Extensive VR System (banner).JPG| left | class=img-responsive | link=]] |
</div> | </div> | ||
</div> | </div> | ||
Line 34: | Line 32: | ||
;Manufacturer online resources: [https://www.carlislesyntec.com/en/Roofing-Products/Specialty/Roof-Garden Roof Garden Systems] | ;Manufacturer online resources: [https://www.carlislesyntec.com/en/Roofing-Products/Specialty/Roof-Garden Roof Garden Systems] | ||
;System Type: Extensive | ;System Type: Extensive | ||
− | ;System Depth: 101.6 mm (4") to | + | ;System Depth: 101.6 mm (4") to 158.8 mm (6-1/4") |
;Growing Media Depth: 70 mm (1-1/4") to 127 mm (5") | ;Growing Media Depth: 70 mm (1-1/4") to 127 mm (5") | ||
;Vegetation Profile: Sedum-Herbaceous-Grass | ;Vegetation Profile: Sedum-Herbaceous-Grass | ||
Line 50: | Line 48: | ||
*[https://rpm.rcabc.org/images/8/80/Carlisle_Roof_Garden_200V-300HV_Protection_Fabrics_TDS.pdf '''300HV Protection Fabric'''] | *[https://rpm.rcabc.org/images/8/80/Carlisle_Roof_Garden_200V-300HV_Protection_Fabrics_TDS.pdf '''300HV Protection Fabric'''] | ||
:'''Conventionally Insulated Roof Assembly''' by roofing ''Contractor'' | :'''Conventionally Insulated Roof Assembly''' by roofing ''Contractor'' | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|} | |} | ||