Difference between revisions of "Materials:ENRGY 3 CGF Insulation"

Jump to: navigation, search

Difference between revisions of "Materials:ENRGY 3 CGF Insulation"

 
(2 intermediate revisions by the same user not shown)
Line 11: Line 11:
 
;Accepted for '''''RoofStar Guarantee Program''''': Date TBA
 
;Accepted for '''''RoofStar Guarantee Program''''': Date TBA
 
;:
 
;:
;'''Product Summary''':  
+
;'''Product Summary''': Johns Manville Corporation manufactures a variety of polyisocyanurate insulations. The insulation panels are manufactured with flexible facers, trilaminate foil, glassmat, or non-asphaltic inorganic matt facers for use in virtually all roof assemblies.
Johns Manville Corporation manufactures a variety of polyisocyanurate insulations. The insulation panels are manufactured with flexible facers, trilaminate foil, glassmat, or non-asphaltic inorganic matt facers for use in virtually all roof assemblies.
 
  
These insulations are lightweight, easy to handle, and fully compatible with recognized roofing systems, deck types and materials. Their closed-cell structure assures long lasting thermal performance. The same polyisocyanurate foam core formulation is used in all the products manufactured by Johns Manville Corporation.  
+
:These insulations are lightweight, easy to handle, and fully compatible with recognized roofing systems, deck types and materials. Their closed-cell structure assures long lasting thermal performance. The same polyisocyanurate foam core formulation is used in all the products manufactured by Johns Manville Corporation.  
  
ENRGY 3 CGF identifies the most widely used insulation using HCFC 141.b in the family of products manufactured by Johns Manville Corporation.  
+
:ENRGY 3 CGF identifies the most widely used insulation using HCFC 141.b in the family of products manufactured by Johns Manville Corporation.
 +
 
 +
:<table border=0 cellpadding=10 cellspacing=0>
 +
<tr>
 +
<td>Long Term Thermal Resistance (LTTR):</td>
 +
<td colspan=2>RSI value = 1.06 / 25 mm (1") [R Value = 6.0 / 25 mm (1")]</td>
 +
</tr>
 +
<tr>
 +
<td>Compressive Strength</td>
 +
<td colspan=2>138 kpa nom (173 kpa available) [20 lb / sq. in nom (25 lb / sq. in available)]</td>
 +
</tr>
 +
<tr>
 +
<td>Uses</td>
 +
<td colspan=2> All conventional single-ply, modified and built-up roofing systems.</td>
 +
</tr>
 +
<tr>
 +
<td>Standards</td>
 +
<td colspan=2>Conforms to CAN / ULC-S704-01 / CAN / CGSB 51.26-M86 (Types 1-4)</td>
 +
</tr>
 +
<tr>
 +
<td></td>
 +
<td colspan=2>FM-Class 1, I-60, I-90</td>
 +
</tr>
 +
<tr>
 +
<td></td>
 +
<td colspan=2>ULC S-126</td>
 +
</tr>
 +
<tr>
 +
<td>Standard Sizes</td>
 +
<td>1.2 m x 1.2 m<br>(4' x 4')</td>   
 +
<td>1.2 m x 2.4 m<br>(4' x 8')</td>
 +
</tr>
 +
<tr>
 +
<td></td>
 +
<td colspan=2>Thicknesses: 25 mm to 104 mm (1" to 4.1")</td>
 +
</tr>
 +
</table>
 +
 
 +
 
 +
<u>TAPERED ENRGY 3 AGF INSULATION</u>
 +
 
 +
Johns Manville Corporation designs and manufactures tapered polyisocyanurate roof insulation systems, with slopes ranging from 1:200 (1/16" in 12") to 1:25 (1/2" in 12"). The most commonly used slopes are 1:100 (1/8" in 12") and 1:50 (1/4" in 12"). Complimentary computerized design service, as well as the normal &#8220;shop drawings&#8221; required for application, are available to the architect / specifier from Johns Manville Corporation.
 
|}
 
|}
  
:Click below for the '''Technical Data Sheet''' (TBA).
+
:Click below for the '''Technical Data Sheet'''.
  
 
<div style="width:150px; text-align: left;">
 
<div style="width:150px; text-align: left;">
:[[File:Pdf.png|150 px|link=http://rpm3.rcabc.org/images/3/30/JM_ENRGY_3_CGF_TDS.pdf|'''Technical Data Sheet''']]
+
:[[File:Pdf.png|150 px|link=http://rpm.rcabc.org/images/3/30/JM_ENRGY_3_CGF_TDS.pdf|'''Technical Data Sheet''']]
 
</div>
 
</div>
  

Latest revision as of 21:32, 3 November 2016

Notice to the Reader:

The roofing assembly / material information published in the RCABC Roofing Practices Manual and offered below does NOT represent a complete set of the manufacturer’s data or specifications. The preparation of a detailed specification is the responsibility of the design authority.

Manufacturer: Johns Manville Corporation
Accepted for RoofStar Guarantee Program
Date TBA
Product Summary
Johns Manville Corporation manufactures a variety of polyisocyanurate insulations. The insulation panels are manufactured with flexible facers, trilaminate foil, glassmat, or non-asphaltic inorganic matt facers for use in virtually all roof assemblies.
These insulations are lightweight, easy to handle, and fully compatible with recognized roofing systems, deck types and materials. Their closed-cell structure assures long lasting thermal performance. The same polyisocyanurate foam core formulation is used in all the products manufactured by Johns Manville Corporation.
ENRGY 3 CGF identifies the most widely used insulation using HCFC 141.b in the family of products manufactured by Johns Manville Corporation.
Long Term Thermal Resistance (LTTR): RSI value = 1.06 / 25 mm (1") [R Value = 6.0 / 25 mm (1")]
Compressive Strength 138 kpa nom (173 kpa available) [20 lb / sq. in nom (25 lb / sq. in available)]
Uses All conventional single-ply, modified and built-up roofing systems.
Standards Conforms to CAN / ULC-S704-01 / CAN / CGSB 51.26-M86 (Types 1-4)
FM-Class 1, I-60, I-90
ULC S-126
Standard Sizes 1.2 m x 1.2 m
(4' x 4')
1.2 m x 2.4 m
(4' x 8')
Thicknesses: 25 mm to 104 mm (1" to 4.1")


TAPERED ENRGY 3 AGF INSULATION

Johns Manville Corporation designs and manufactures tapered polyisocyanurate roof insulation systems, with slopes ranging from 1:200 (1/16" in 12") to 1:25 (1/2" in 12"). The most commonly used slopes are 1:100 (1/8" in 12") and 1:50 (1/4" in 12"). Complimentary computerized design service, as well as the normal “shop drawings” required for application, are available to the architect / specifier from Johns Manville Corporation.

Click below for the Technical Data Sheet.
Technical Data Sheet



Back to Accepted Materials


Home