Difference between revisions of "Materials:ENRGY 3 CGF Insulation"
Difference between revisions of "Materials:ENRGY 3 CGF Insulation"
(2 intermediate revisions by the same user not shown) | |||
Line 11: | Line 11: | ||
;Accepted for '''''RoofStar Guarantee Program''''': Date TBA | ;Accepted for '''''RoofStar Guarantee Program''''': Date TBA | ||
;: | ;: | ||
− | ;'''Product Summary''': | + | ;'''Product Summary''': Johns Manville Corporation manufactures a variety of polyisocyanurate insulations. The insulation panels are manufactured with flexible facers, trilaminate foil, glassmat, or non-asphaltic inorganic matt facers for use in virtually all roof assemblies. |
− | Johns Manville Corporation manufactures a variety of polyisocyanurate insulations. The insulation panels are manufactured with flexible facers, trilaminate foil, glassmat, or non-asphaltic inorganic matt facers for use in virtually all roof assemblies. | ||
− | These insulations are lightweight, easy to handle, and fully compatible with recognized roofing systems, deck types and materials. Their closed-cell structure assures long lasting thermal performance. The same polyisocyanurate foam core formulation is used in all the products manufactured by Johns Manville Corporation. | + | :These insulations are lightweight, easy to handle, and fully compatible with recognized roofing systems, deck types and materials. Their closed-cell structure assures long lasting thermal performance. The same polyisocyanurate foam core formulation is used in all the products manufactured by Johns Manville Corporation. |
− | ENRGY 3 CGF identifies the most widely used insulation using HCFC 141.b in the family of products manufactured by Johns Manville Corporation. | + | :ENRGY 3 CGF identifies the most widely used insulation using HCFC 141.b in the family of products manufactured by Johns Manville Corporation. |
+ | |||
+ | :<table border=0 cellpadding=10 cellspacing=0> | ||
+ | <tr> | ||
+ | <td>Long Term Thermal Resistance (LTTR):</td> | ||
+ | <td colspan=2>RSI value = 1.06 / 25 mm (1") [R Value = 6.0 / 25 mm (1")]</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Compressive Strength</td> | ||
+ | <td colspan=2>138 kpa nom (173 kpa available) [20 lb / sq. in nom (25 lb / sq. in available)]</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Uses</td> | ||
+ | <td colspan=2> All conventional single-ply, modified and built-up roofing systems.</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Standards</td> | ||
+ | <td colspan=2>Conforms to CAN / ULC-S704-01 / CAN / CGSB 51.26-M86 (Types 1-4)</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td></td> | ||
+ | <td colspan=2>FM-Class 1, I-60, I-90</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td></td> | ||
+ | <td colspan=2>ULC S-126</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Standard Sizes</td> | ||
+ | <td>1.2 m x 1.2 m<br>(4' x 4')</td> | ||
+ | <td>1.2 m x 2.4 m<br>(4' x 8')</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td></td> | ||
+ | <td colspan=2>Thicknesses: 25 mm to 104 mm (1" to 4.1")</td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | |||
+ | <u>TAPERED ENRGY 3 AGF INSULATION</u> | ||
+ | |||
+ | Johns Manville Corporation designs and manufactures tapered polyisocyanurate roof insulation systems, with slopes ranging from 1:200 (1/16" in 12") to 1:25 (1/2" in 12"). The most commonly used slopes are 1:100 (1/8" in 12") and 1:50 (1/4" in 12"). Complimentary computerized design service, as well as the normal “shop drawings” required for application, are available to the architect / specifier from Johns Manville Corporation. | ||
|} | |} | ||
− | :Click below for the '''Technical Data Sheet''' | + | :Click below for the '''Technical Data Sheet'''. |
<div style="width:150px; text-align: left;"> | <div style="width:150px; text-align: left;"> | ||
− | :[[File:Pdf.png|150 px|link=http:// | + | :[[File:Pdf.png|150 px|link=http://rpm.rcabc.org/images/3/30/JM_ENRGY_3_CGF_TDS.pdf|'''Technical Data Sheet''']] |
</div> | </div> | ||
Latest revision as of 21:32, 3 November 2016
Notice to the Reader:
The roofing assembly / material information published in the RCABC Roofing Practices Manual and offered below does NOT represent a complete set of the manufacturer’s data or specifications. The preparation of a detailed specification is the responsibility of the design authority. |
Manufacturer: Johns Manville Corporation
|
- Click below for the Technical Data Sheet.