==== WORK INCLUDED ====
+
<big><big>Division D - Construction Details</big></big>
 
+
<hr>
(1)<b> Primary Waterproofing Membrane:</b> Fully adhered to acceptable substrates (concrete slab shown), installed a per <i>RGC Guarantee Standards E</i> and Membrane Manufacturer's installation specifications.
+
<big><big><big><big><big>WP Details:F1.7.1(Wearing Course - Concrete Pavers)</big></big></big></big></big>
 
+
{| class="wikitable" | style="color: black; background-color: orange; width: 100%;text-align:center"
(2) <b>Membrane Primer or Adhesive:</b> Proprietary primer or adhesive, application method and quantities for substrate type as directed by membrane manufacturers published application specifications.  
+
| colspan="2"  | <big>'''''Notice to Reader'''''</big>
 
+
|-
(3) <b>Protection Board/Mat: </b>Proprietary membrane protection board or drainage board approved by membrane manufacture, compatible with waterproofing membrane system, and compliant with RGC Guarantee Standards <b>E.</b>  
+
| style="color: black; background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive.  Nor are they necessarily drawn to scale. Rather, they are provided to visually convey the requirements of the Standard they represent. Unless otherwise required by the Standard, dimensions, the selection of materials and their application remains the responsibility of the ''Design Authority''.<br><br>The full text of the referenced requirements in the [[Grade-level Waterproofing Standard | '''Standard''']] may be read by using the <span style="color:#6495ed">'''blue hyperlinks'''</span>
 
+
|}
(4) <b>Pedestal</b>: Proprietary (purpose-made) pedestals, with integral spacer ribs for uniform spacing between pavers that provide a minimum 12.5 mm (1/2") of vertical separation layer for airflow and levelling. Alternative: drainage boards with sand and gravel beds for unit masonry designed to provide permeable layer and levelling.
+
<div class="panel panel-success">
 +
<div class="panel-heading"><big>'''Waterproofing Details for Plazas, Promenades and Terraces'''</big></div>
 +
<div class="panel-body">
 +
<div class="col-md-6">
 +
<div style="text-align:center; vertical-align:center">
 +
[[File:9.6.1.jpg| link=http://rpm.rcabc.org/images/2/2b/9.6.1.jpg | class=img-responsive]]
 +
</div>
 +
</div><!-- COL-MD-6 -->
  
(7) <b>Concrete Paver: </b>Designed to support predicted live loads, maximum size 200mm (24") by 200mm (24").
+
<div class="col-md-6">
 +
=== WORK INCLUDED ===
  
 +
;(1) [[Grade-level Waterproofing Standard#WPMEMBRANE | '''Primary Waterproofing Membrane''']]: Fully adhered to acceptable substrates (concrete slab shown), installed as per the [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing '''RoofStar Guarantee Standards for Waterproofing Plazas, Promenades & Terraces'''] and Membrane Manufacturer's installation specifications.
 +
;(2) Membrane Primer or Adhesive: Proprietary primer or adhesive, application method and quantities for substrate type as directed by membrane manufacturers published application specifications.
 +
;(3) [[Grade-level Waterproofing Standard#WPPROTECTION | '''Protection Board/Mat''']]: Proprietary membrane protection board or drainage board approved by membrane manufacture, compatible with waterproofing membrane system, and compliant with the [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing '''RoofStar Guarantee Standards for Waterproofing Plazas, Promenades & Terraces''']
 +
;(4) [[Grade-level Waterproofing Standard#WPWEARING | '''Pedestal''']]: Proprietary (purpose-made) pedestals, with integral spacer ribs for uniform spacing between pavers that provide a minimum 12.5 mm (1/2") of vertical separation layer for airflow and levelling. Alternative: drainage boards with sand and gravel beds for unit masonry designed to provide permeable layer and leveling.
 +
;(5) [[Grade-level Waterproofing Standard#WPWEARING |'''Pavers''']]: Designed to support predicted live loads, maximum size 600mm (24") by 600mm (24").
  
==== WORK BY OTHERS ====
+
=== WORK BY OTHERS ===
 +
;(A) [[Grade-level Waterproofing Standard#WPDECK |'''Acceptable Deck''']]: Concrete slab depicted.
 +
</div><!-- COL-6-MD -->
 +
</div><!-- PANEL BODY -->
 +
</div><!-- PANEL -->
  
(A)<b>Acceptable Deck</b>: Concrete slab depicted.
+
'''NOTE''': See the [[Grade-level Waterproofing Standard | '''Standard''']] for additional requirements.
 
 
<i>NOTE: </i>Refer to <i>RGC Guarantee Standards E</i> for additional requirements.
 
  
 
<hr>
 
<hr>
  
 +
[[Grade-level Waterproofing System Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Grade-level Waterproofing Construction Details'']]
  
 +
[[Main Page | <i class="fa fa-home fa"></i> Home]]
  
 
+
{{Tempate:RPM Page Footer with Copyright and Current Date}}
[[Section:F. Application: Waterproofing Plazas, Promenades and Terraces|<i class="fa fa-chevron-circle-left fa-2x" ></i> Back to ''Waterproofing Application'']]
 
 
 
[[Waterproofing Construction Details|<i class="fa fa-chevron-circle-left fa-2x" ></i> Back to ''Waterproofing Construction Details'']]
 
 
 
[[Section:G. Construction Details|<i class="fa fa-chevron-circle-left fa-2x" ></i> Back to ''Construction Details'']]
 

Latest revision as of 21:14, 7 September 2021



Division D - Construction Details


WP Details:F1.7.1(Wearing Course - Concrete Pavers)

Notice to Reader
Images used in a Construction Detail are representative and not prescriptive. Nor are they necessarily drawn to scale. Rather, they are provided to visually convey the requirements of the Standard they represent. Unless otherwise required by the Standard, dimensions, the selection of materials and their application remains the responsibility of the Design Authority.

The full text of the referenced requirements in the Standard may be read by using the blue hyperlinks
Waterproofing Details for Plazas, Promenades and Terraces

9.6.1.jpg

1 WORK INCLUDED

(1) Primary Waterproofing Membrane
Fully adhered to acceptable substrates (concrete slab shown), installed as per the RoofStar Guarantee Standards for Waterproofing Plazas, Promenades & Terraces and Membrane Manufacturer's installation specifications.
(2) Membrane Primer or Adhesive
Proprietary primer or adhesive, application method and quantities for substrate type as directed by membrane manufacturers published application specifications.
(3) Protection Board/Mat
Proprietary membrane protection board or drainage board approved by membrane manufacture, compatible with waterproofing membrane system, and compliant with the RoofStar Guarantee Standards for Waterproofing Plazas, Promenades & Terraces
(4) Pedestal
Proprietary (purpose-made) pedestals, with integral spacer ribs for uniform spacing between pavers that provide a minimum 12.5 mm (1/2") of vertical separation layer for airflow and levelling. Alternative: drainage boards with sand and gravel beds for unit masonry designed to provide permeable layer and leveling.
(5) Pavers
Designed to support predicted live loads, maximum size 600mm (24") by 600mm (24").

2 WORK BY OTHERS

(A) Acceptable Deck
Concrete slab depicted.

NOTE: See the Standard for additional requirements.