Difference between revisions of "Materials:NLSM StormCap Detain 3°"
Difference between revisions of "Materials:NLSM StormCap Detain 3°"
(Created page with "__NOTOC__ __NONUMBEREDHEADINGS__ {{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}} <big>...") |
|||
(6 intermediate revisions by the same user not shown) | |||
Line 11: | Line 11: | ||
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
− | | style="background-color:#FFFACD" | '''<big>Material Acceptance and Product Details</big>''' | + | | style="background-color:#FFFACD" | '''<big>System/Material Acceptance and Product Details</big>''' |
<br> | <br> | ||
− | The information published in the RCABC '''''Roofing Practices Manual''''' and offered below does NOT represent a complete set of the manufacturer’s data or specifications, nor is this | + | The information published in the RCABC '''''Roofing Practices Manual''''' and offered below does NOT represent a complete set of the manufacturer’s data or specifications, nor is this system and its various materials recommended or endorsed by the ''Guarantor''. The preparation of a detailed specification is the responsibility of the ''Design Authority''. |
|- | |- | ||
| | | | ||
<div class="col-md-12"> | <div class="col-md-12"> | ||
− | <div class="col-md- | + | <div class="col-md-6"> |
;: | ;: | ||
− | ;'''Vegetated Roof System Manufacturer''': | + | ;'''Vegetated Roof System Manufacturer''': [https://www.nlsm.ca/ '''https://www.nlsm.ca/'''] |
;Accepted for the ''RoofStar Guarantee Program'': October 25, 2024 | ;Accepted for the ''RoofStar Guarantee Program'': October 25, 2024 | ||
;Accepted for application in: Vegetated Roof Systems | ;Accepted for application in: Vegetated Roof Systems | ||
;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]] | ;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]] | ||
+ | ;System Summary: '''StormCap™ Detain 3°''' is designed to manage stormwater on the roof by providing retention and detention, making it a full-fledged stormwater tool ready to face second day and extra-large storms. '''StormCap™ Detain 3°''' reduces or eliminates the need for cisterns and bioretention facilities and frees up valuable space for income-generating development. It is also designed to work on sloped roofs (adapted from the manufacturer's literature. See the link at right to the manufacturer's online resources page for more information). | ||
<div style="text-align: left;"> | <div style="text-align: left;"> | ||
− | [[File:Extensive VR System ( | + | [[File:Extensive VR System (banner).JPG| left | class=img-responsive | link=]] |
</div> | </div> | ||
</div> | </div> | ||
<div class="col-md-6"> | <div class="col-md-6"> | ||
;: | ;: | ||
− | ;System | + | ;Manufacturer Online Resource: [https://www.nlsm.ca/systems-technical-info-2/extensive-systems/detention/ StormCap Detain 3° System] |
− | ;System Depth: | + | ;System Type: Extensive |
− | ;Growing Media Depth: | + | ;System Depth: 114 mm (4-1/2") to 352 mm (13-7/8") |
− | ;Vegetation Profile: | + | ;Growing Media Depth: 70 mm (2-3/4") to 170 mm (6-11/16") |
− | ;Suitable climate zones: | + | ;Vegetation Profile: Moss-Sedum |
− | ;System Components: | + | ;Suitable climate zones: All BC zones, subject to manufacturer's approval |
− | + | ;System Components<sup>*</sup>: In the usual order, from top to bottom; click on link for Technical Data Sheet (TDS) | |
− | : | + | :{| class="wikitable" |
− | : | + | |- |
− | : | + | | |
− | : | + | *[https://rpm.rcabc.org/images/b/bd/NLSM_NL718_Sedum_Blanket_-_Standard_Mix_BC_TDS.pdf '''NL718 Sedum Blanket'''] |
+ | *[https://rpm.rcabc.org/images/2/25/NLSM_NL600_Growing_Medium_HOM_-_BC_G_TDS.pdf '''NL600 Growing Medium'''] | ||
+ | *[https://rpm.rcabc.org/images/6/61/NLSM_NL501_Needled_Mineral_Hydro_Blanket_TDS.pdf '''NL501 NM Hydro Blanket'''] (thickness varies from 2.5 to 7.5 cm) | ||
+ | *[https://rpm.rcabc.org/images/e/e3/NLSM_NL351_Reservoir_Cell_TDS.pdf '''NL351 Reservoir Cell'''] (thickness varies from 1.25 to 10 cm) | ||
+ | *[https://rpm.rcabc.org/images/1/1e/NLSM_NL350_Detention_Mat_TDS.pdf '''NL350 Detention Mat'''] | ||
+ | *[https://rpm.rcabc.org/images/3/32/NLSM_NL120_Root_Barrier_TDS.pdf '''NL120 Root Barrier'''] | ||
+ | :'''Conventionally Insulated Roof Assembly''' by roofing ''Contractor'' | ||
+ | *'''NL201 Non-Perforated Edging''' | ||
+ | *'''NL211 Drainbox''' | ||
+ | |} | ||
+ | |||
+ | </div> | ||
+ | <div class="col-md-12"> | ||
+ | <hr> | ||
+ | <div class="col-md-6"> | ||
+ | |||
+ | ;<sup>†</sup>Guarantor's Notes: Systems labeled "Inverted" are designed for a ''protected membrane roof assembly'', also known as an inverted ''roof assembly''. | ||
+ | |||
+ | :Note that perforated edge metal is required in the "RGC Standard for Vegetated Roofs"; therefore, when a system specifies materials that do not conform to the Standard, the ''Design Authority'' must request a written Variance from the '''''Guarantor'''''. | ||
+ | |||
+ | :In addition, while ''Semi-intensive'' and ''Intensive vegetated roof systems'' are limited to only ''protected membrane roofs'' (See the [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.2._Permitted_Vegetated_Roof_Systems Sentence 1.1.3.2.(5)] in the "RGC Standard for Vegetated Roofs"), some vegetated roof system manufacturers offer their systems for ''conventionally insulated roofs''. To request a written Variance to the published limitation, follow the requirements in [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.6._Variances Article 1.1.3.6.]. | ||
+ | |||
+ | </div> | ||
+ | <div class="col-md-6"> | ||
+ | |||
+ | ;<sup>*</sup>Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements. Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight. | ||
+ | |||
+ | :Also note that vegetation coverage under the '''''RoofStar Vegetated Roof Guarantee''''' applies only to ''extensive systems'' planted with mats or trays - see [https://rpm.rcabc.org/index.php?title=Guarantee Part 3] of Division A for more about coverage. | ||
− | |||
</div> | </div> | ||
</div> | </div> | ||
+ | <div class="col-md-12"> | ||
+ | <br> | ||
|} | |} | ||
Latest revision as of 21:52, 2 December 2024
Division C - Accepted Materials
Group - Vegetated Roof Systems
NLSM StormCap Detain 3°
by Next Level Stormwater Management
System/Material Acceptance and Product Details
| |
|