Difference between revisions of "Materials:ZinCo Roof Garden Assembly (Inverted)"
Difference between revisions of "Materials:ZinCo Roof Garden Assembly (Inverted)"
(Created page with "__NOTOC__ __NONUMBEREDHEADINGS__ {{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}} <big>...") |
|||
| (6 intermediate revisions by the same user not shown) | |||
| Line 19: | Line 19: | ||
<div class="col-md-6"> | <div class="col-md-6"> | ||
;: | ;: | ||
| − | ;'''Vegetated Roof System Manufacturer''': | + | ;'''Vegetated Roof System Manufacturer''': [https://www.zinco.ca/ '''ZinCo Canada Inc.'''] |
;Accepted for the ''RoofStar Guarantee Program'': October 25, 2024 | ;Accepted for the ''RoofStar Guarantee Program'': October 25, 2024 | ||
;Accepted for application in: Vegetated Roof Systems | ;Accepted for application in: Vegetated Roof Systems | ||
;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]] | ;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]] | ||
| − | ;System Summary: | + | ;System Summary: ZinCo Canada's '''Roof Garden Assembly''' is designed as a multifunctional green roof with a high capacity for water retention, allowing you to include a wider variety of plants. ZinCo's Roof Garden Assembly Features: |
| + | :*Supports lawns, perennials, shrubs and even trees | ||
| + | :*Can include paths, terraces, driveways or playgrounds | ||
| + | :*Structures can be built directly on the Floradrain® FD 60 system, without penetrating the roof membrane or impairing the drainage. | ||
| + | :(adapted from the manufacturer's literature) | ||
| + | |||
| + | |||
| + | |||
| + | |||
| + | <br> | ||
<div style="text-align: left;"> | <div style="text-align: left;"> | ||
| − | [[File:Extensive VR System ( | + | [[File:Extensive VR System (banner).JPG| left | class=img-responsive | link=]] |
</div> | </div> | ||
</div> | </div> | ||
<div class="col-md-6"> | <div class="col-md-6"> | ||
;: | ;: | ||
| − | ;Manufacturer Online Resource: [ | + | ;Manufacturer Online Resource: [https://www.zinco.ca/roof-garden ZinCo Roof Garden] |
| − | ;System Depth: | + | ;System Type: Intensive |
| − | ;Growing Media Depth: | + | ;System Depth: 241.3 mm (9-1/2") to 260.35 mm (10-1/4") |
| − | ;Vegetation Profile: | + | ;Growing Media Depth: 203.1 mm (8") to 203.1 mm (8") |
| − | ;Suitable climate zones: | + | ;Vegetation Profile: Trees, Shrubs, Perennials, Grasses, Herbacious, Sedums |
| − | ;System Components: | + | ;Suitable climate zones: All BC zones, subject to manufacturer's approval |
| − | + | ;System Components<sup>*</sup>: In the usual order, from top to bottom; click on link for Technical Data Sheet (TDS) | |
| − | : | + | :{| class="wikitable" |
| − | : | + | |- |
| − | : | + | | |
| − | : | + | *'''Perennials-Grasses-Herbacious-Sedums''' (See pre-grown vegetation by ZinCo Canada) or as specified by the ''Design Authority''/''Green Roof Design Professional'' (See '''Conditions and Limitations''' below) |
| + | *[https://rpm.rcabc.org/images/e/e3/ZinCo_System_Growing_Medium_%28ZinCo_Blend_I%29_TDS.pdf '''Growing Medium Blend-I'''] | ||
| + | *[https://rpm.rcabc.org/images/9/91/ZinCo_Filter_Sheet_SF_TDS.pdf '''Filter Sheet SF'''] | ||
| + | *[https://rpm.rcabc.org/images/c/c0/ZinCo_Floradrain_FD60_TDS.pdf '''Floradrain FD60-E'''] | ||
| + | **[https://rpm.rcabc.org/images/6/62/ZinCo_Floradrain_FD40-E_TDS.pdf '''Floradrain FD40-E'''] (alternate drainage board) | ||
| + | **[https://rpm.rcabc.org/images/7/75/ZinCo_Floradrain_FD25-E_TDS.pdf '''Floradrain FD25-E'''] (alternate drainage board) | ||
| + | *[https://rpm.rcabc.org/images/4/40/ZinCo_Separation_Membrane_TGV21_TDS.pdf '''TGV 21 Diffusion Membrane'''] | ||
| + | :'''XPS Insulation''' by roofing ''Contractor'' (Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]]) | ||
| + | *[https://rpm.rcabc.org/images/2/2e/ZinCo_Root_Barrier_WSB100-PO_TDS.pdf '''Root Barrier WSB100-PO'''] | ||
| + | **[https://rpm.rcabc.org/images/0/09/ZinCo_Root_Barrier_WSF40_TDS.pdf '''Root Barrier WSF40'''] (alternate root barrier) | ||
| + | :'''Waterproofing Roof Assembly''' (membrane) by roofing ''Contractor'' | ||
| + | |||
| + | *[https://rpm.rcabc.org/images/c/c4/ZinCo_Eaves_Profile_DP300_TDS.pdf '''Edging Profile DP300'''] or [https://rpm.rcabc.org/images/d/df/ZinCo_Eaves_Profile_DP250_TDS.pdf '''Edging Profile DP250'''] | ||
| + | *[https://rpm.rcabc.org/images/9/92/ZinCo_Inspection_Chamber_KS30-E_Stainless_steel_TDS.pdf '''Inspection Chamber KS30SS'''] | ||
| + | |} | ||
| + | </div> | ||
| + | <div class="col-md-12"> | ||
| + | <hr> | ||
| + | <div class="col-md-6"> | ||
| + | |||
| + | ;<sup>†</sup>Guarantor's Notes: Systems labeled "Inverted" are designed for a ''protected membrane roof assembly'', also known as an inverted ''roof assembly''. | ||
| + | |||
| + | :While ''Semi-intensive'' and ''Intensive vegetated roof systems'' are limited to only ''protected membrane roofs'' (See the [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.2._Permitted_Vegetated_Roof_Systems Sentence 1.1.3.2.(5)] in the "RGC Standard for Vegetated Roofs"), some vegetated roof system manufacturers offer their systems for ''conventionally insulated roofs''. To request a written Variance to the published limitation, follow the requirements in [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.6._Variances Article 1.1.3.6.]. | ||
| + | |||
| + | </div> | ||
| + | <div class="col-md-6"> | ||
;<sup>*</sup>Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements. Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight. | ;<sup>*</sup>Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements. Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight. | ||
:Also note that vegetation coverage under the '''''RoofStar Vegetated Roof Guarantee''''' applies only to ''extensive systems'' planted with mats or trays - see [https://rpm.rcabc.org/index.php?title=Guarantee Part 3] of Division A for more about coverage. | :Also note that vegetation coverage under the '''''RoofStar Vegetated Roof Guarantee''''' applies only to ''extensive systems'' planted with mats or trays - see [https://rpm.rcabc.org/index.php?title=Guarantee Part 3] of Division A for more about coverage. | ||
| + | |||
</div> | </div> | ||
</div> | </div> | ||
<div class="col-md-12"> | <div class="col-md-12"> | ||
| − | |||
| − | |||
<br> | <br> | ||
|} | |} | ||
Latest revision as of 17:23, 28 November 2024
Division C - Accepted Materials
Group - Vegetated Roof Systems
ZinCo Roof Garden Assembly (Inverted†)
by ZinCo Canada Inc.
| System/Material Acceptance and Product Details
| |
|