Difference between revisions of "EPDM Plumbing Vent (Conventional Roof System)"

Jump to: navigation, search

Difference between revisions of "EPDM Plumbing Vent (Conventional Roof System)"

(Created page with " {{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}} __NOTOC__ <big><big>Division D - Con...")
 
(WORK INCLUDED)
 
(3 intermediate revisions by the same user not shown)
Line 8: Line 8:
 
<big><big><big><big><big>EPDM | Plumbing Vent (Conventional Roof System)</big></big></big></big></big>
 
<big><big><big><big><big>EPDM | Plumbing Vent (Conventional Roof System)</big></big></big></big></big>
 
{{Template:Construction Details Header}}
 
{{Template:Construction Details Header}}
<div class="panel panel-success">
+
<div class="panel panel-info">
 
<div class="panel-heading"><big>'''EPDM Details'''</big></div>
 
<div class="panel-heading"><big>'''EPDM Details'''</big></div>
 
<div class="panel-body">
 
<div class="panel-body">
Line 14: Line 14:
 
<div style="text-align:center; vertical-align:center">
 
<div style="text-align:center; vertical-align:center">
 
<br>
 
<br>
[[File:Illustration Unavailable (Filler Image).png |class=img-responsive | link=https://rpm.rcabc.org/images/6/6a/Illustration_Unavailable_%28Filler_Image%29.png]]
+
[[File:Part 12 - CD - Plumbing Vent - EPDM.png |class=img-responsive | link=https://rpm.rcabc.org/images/f/fa/Part_12_-_CD_-_Plumbing_Vent_-_EPDM.png]]
 
:Drawing NTS
 
:Drawing NTS
 
</div>
 
</div>
Line 21: Line 21:
 
<div class="col-md-6">
 
<div class="col-md-6">
 
=== WORK INCLUDED ===
 
=== WORK INCLUDED ===
 +
;(1) [[EPDM Roof Systems Standard#PART_5|'''Supporting Deck Overlay''']]: If specified and included in a ''Tested Assembly'', an ''Assembly with Proven Past Performance'', or a custom-engineered assembly.
 +
;(2) [[EPDM Roof Systems Standard#PART_6|'''Air or Vapour Control Layers''']]: As required by ''Design Authority''.
 +
;(3) [[EPDM Roof Systems Standard#PART_6|'''Air or Vapour Control Layer Tie-in''']]: Illustrated to show AVB continuity with penetration.
 +
;(4) [[EPDM Roof Systems Standard#PART_7|'''Insulation''']]: Multiple layering shown (Refer to '''Part 7''' for design, material, and installation requirements).
 +
;(5) [[EPDM Roof Systems Standard#PART_8|'''Insulation Overlay''']]: As required by the RGC Standard; see '''Part 8''' for design, material, and installation requirements. Additionally, an overlay is required is included in a ''Tested Assembly'', an ''Assembly with Proven Past Performance'', or a custom-engineered assembly.
 +
;(6) [[EPDM Roof Systems Standard#PART_9|'''Field Sheet Membrane''']]: Selected to conform to the requirements in [https://rpm.rcabc.org/index.php?title=EPDM_Roof_Systems_Standard#9.2.1.1._Membrane_Composition,_Thickness,_and_Selection '''Table 9.2.1.1.'''] and conforming to the options or requirements in a ''Tested Assembly'', an ''Assembly with Proven Past Performance'', or a custom-engineered assembly.
 +
;(7) [[EPDM Roof Systems Standard#PART_12 | '''Wood Blocking''']]: Optional (only required with metal flanged penetration flashings).
 +
;(8) [[EPDM Roof Systems Standard#PART_12 | '''Penetration Flashing''']]: Purpose-made plumbing vent flashing fabricated and supplied by the membrane ''manufacturer''. Adhere to field membrane with proprietary sealant.
 +
;(9) [[EPDM Roof Systems Standard#PART_12 | '''Edge Sealant''']]: Proprietary (membrane manufacturer) and applied to edge of membrane.
 +
;(10) [[EPDM Roof Systems Standard#PART_12 | '''Sealant''']]: Proprietary (membrane manufacturer) and applied to edge of boot flashing.
 +
;(11) [[EPDM Roof Systems Standard#PART_12 | '''Mechanical Band Clamp''']]:Required by the RGC Standard.
  
;This Page is under construction.
+
<hr>
  
 
=== RELATED WORK BY OTHERS ===
 
=== RELATED WORK BY OTHERS ===
;This Page is under construction
+
;(A) [[EPDM Roof Systems Standard#PART_2|'''Supporting (Structural) Roof Deck''']]: Steel deck illustrated.
 +
;(B) '''Plumbing Penetration''': Extend to match top of metal flashing.
  
 
</div><!-- COL-6-MD -->
 
</div><!-- COL-6-MD -->
Line 37: Line 49:
 
[[EPDM Roof System Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''EPDM Roof System Details'']]
 
[[EPDM Roof System Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''EPDM Roof System Details'']]
  
[[Main Page | <i class="fa fa-home fa"></i> Home]]
+
[[RCABC Roofing Practices Manual | <i class="fa fa-home fa"></i> Home]]
  
 
{{Template:RPM Page Footer with Copyright and Current Date}}
 
{{Template:RPM Page Footer with Copyright and Current Date}}

Latest revision as of 23:26, 6 November 2025



Division D - Construction Details


EPDM | Plumbing Vent (Conventional Roof System)

Notice to Reader
Images used in a Construction Detail are representative and not prescriptive, and are not necessarily drawn to scale. They are intended to support the related Standard (Ref. Division A, Article 2.2.1.2.).

The reader may link to the related Article in the detail title, or link to the Standard as it relates to a specific element in the detail. All hyperlinks are displayed blue text.

EPDM Details


Part 12 - CD - Plumbing Vent - EPDM.png

Drawing NTS

1 WORK INCLUDED

(1) Supporting Deck Overlay
If specified and included in a Tested Assembly, an Assembly with Proven Past Performance, or a custom-engineered assembly.
(2) Air or Vapour Control Layers
As required by Design Authority.
(3) Air or Vapour Control Layer Tie-in
Illustrated to show AVB continuity with penetration.
(4) Insulation
Multiple layering shown (Refer to Part 7 for design, material, and installation requirements).
(5) Insulation Overlay
As required by the RGC Standard; see Part 8 for design, material, and installation requirements. Additionally, an overlay is required is included in a Tested Assembly, an Assembly with Proven Past Performance, or a custom-engineered assembly.
(6) Field Sheet Membrane
Selected to conform to the requirements in Table 9.2.1.1. and conforming to the options or requirements in a Tested Assembly, an Assembly with Proven Past Performance, or a custom-engineered assembly.
(7) Wood Blocking
Optional (only required with metal flanged penetration flashings).
(8) Penetration Flashing
Purpose-made plumbing vent flashing fabricated and supplied by the membrane manufacturer. Adhere to field membrane with proprietary sealant.
(9) Edge Sealant
Proprietary (membrane manufacturer) and applied to edge of membrane.
(10) Sealant
Proprietary (membrane manufacturer) and applied to edge of boot flashing.
(11) Mechanical Band Clamp
Required by the RGC Standard.

2 RELATED WORK BY OTHERS

(A) Supporting (Structural) Roof Deck
Steel deck illustrated.
(B) Plumbing Penetration
Extend to match top of metal flashing.

NOTE: See the EPDM Roof Systems Standard for additional requirements.