Difference between revisions of "PVC Expansion Joint (Field)"
Difference between revisions of "PVC Expansion Joint (Field)"
(Created page with "{{Template:RPM Info}} {{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}} __NOTOC__ <big>...") |
|||
| Line 6: | Line 6: | ||
<big><big>Division D - Construction Details</big></big> | <big><big>Division D - Construction Details</big></big> | ||
<hr> | <hr> | ||
| − | <big><big><big><big><big>PVC | Expansion Joint (Field)</big></big></big></big></big> | + | <big><big><big><big><big>PVC | Expansion Joint (Field) ([[PVC_Roof_Systems_Standard#10.3.6.1._Expansion_Joints |Article 10.3.6.1.]])</big></big></big></big></big> |
{{Template:Construction Details Header}} | {{Template:Construction Details Header}} | ||
<div class="panel panel-info"> | <div class="panel panel-info"> | ||
| − | <div class="panel-heading"><big>''' | + | <div class="panel-heading"><big>'''SBS Details'''</big></div> |
<div class="panel-body"> | <div class="panel-body"> | ||
| − | <div class="col-md- | + | <div class="col-md-7"> |
<div style="text-align:center; vertical-align:center"> | <div style="text-align:center; vertical-align:center"> | ||
| − | + | [[File:Part 10 - CD - Expansion Joints (Field) PVC.png |link=https://rpm.rcabc.org/images/a/ad/Part_10_-_CD_-_Expansion_Joints_%28Field%29_PVC.png | class=img-responsive]] | |
| − | [[File: | ||
| − | |||
</div> | </div> | ||
| − | </div><!-- COL- | + | </div><!-- COL-MD-7 --> |
| − | <div class="col-md- | + | <div class="col-md-5"> |
=== WORK INCLUDED === | === WORK INCLUDED === | ||
| + | ;(1) [[EPDM Roof Systems Standard#PART_10|'''Roof membrane''']]: Waterproofs the expansion joint structure and provides a base layer for the control joint material to bond with. | ||
| + | ;(2) [[EPDM Roof Systems Standard#PART_10|'''Expansion joint (elastomeric product illustrated)''']]: This joint is proprietary to its manufacturer and will be fitted, manufactured, and installed (or its installation supervised) by others. Secured to substrate as required by manufacturer. | ||
| + | ;(3) '''Reinforced membrane strip''': Applied to cover the control joint and seal it to the membrane system. | ||
| + | ;(4) [[EPDM Roof Systems Standard#PART_13|'''Metal cap (coping) flashing''']]: Fabricated and installed as required in Part 13. | ||
| + | ;(5) [[EPDM Roof Systems Standard#PART_13|'''Metal counter-flashing''']]: The counter-flashing below the cap flashing is secured independently of the metal cap flashing to permit movement of the expansion joint assembly across the planes of anticipated structural movement. Dimensions are project-specific. | ||
| − | + | ||
| + | <hr> | ||
=== RELATED WORK BY OTHERS === | === RELATED WORK BY OTHERS === | ||
| − | ; | + | ;(A) [[PVC Roof Systems Standard#PART_2|'''Acceptable deck''']] |
| − | + | ;(B) '''Expansion joint structure''' | |
| − | </div><!-- COL- | + | </div><!-- COL-5-MD --> |
</div><!-- PANEL BODY --> | </div><!-- PANEL BODY --> | ||
</div><!-- PANEL --> | </div><!-- PANEL --> | ||
| − | '''NOTE''': See the [[PVC Roof Systems Standard | ''' | + | '''NOTE''': See the [[PVC Roof Systems Standard | '''Standard''']] for additional requirements. |
<hr> | <hr> | ||
| Line 37: | Line 41: | ||
[[PVC Roof System Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''PVC Roof System Details'']] | [[PVC Roof System Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''PVC Roof System Details'']] | ||
| − | [[ | + | [[Main Page | <i class="fa fa-home fa"></i> Home]] |
{{Template:RPM Page Footer with Copyright and Current Date}} | {{Template:RPM Page Footer with Copyright and Current Date}} | ||
Latest revision as of 15:36, 30 October 2026
Division D - Construction Details
PVC | Expansion Joint (Field) (Article 10.3.6.1.)
| Notice to Reader | |
| Images used in a Construction Detail are representative and not prescriptive, and are not necessarily drawn to scale. They are intended to support the related Standard (Ref. Division A, Article 2.2.1.2.).
The reader may link to the related Article in the detail title, or link to the Standard as it relates to a specific element in the detail. All hyperlinks are displayed blue text. | |
SBS Details
1 WORK INCLUDED
- (1) Roof membrane
- Waterproofs the expansion joint structure and provides a base layer for the control joint material to bond with.
- (2) Expansion joint (elastomeric product illustrated)
- This joint is proprietary to its manufacturer and will be fitted, manufactured, and installed (or its installation supervised) by others. Secured to substrate as required by manufacturer.
- (3) Reinforced membrane strip
- Applied to cover the control joint and seal it to the membrane system.
- (4) Metal cap (coping) flashing
- Fabricated and installed as required in Part 13.
- (5) Metal counter-flashing
- The counter-flashing below the cap flashing is secured independently of the metal cap flashing to permit movement of the expansion joint assembly across the planes of anticipated structural movement. Dimensions are project-specific.
2 RELATED WORK BY OTHERS
- (A) Acceptable deck
- (B) Expansion joint structure
NOTE: See the Standard for additional requirements.
Back to PVC Roof System Details
© RCABC 2026
RoofStarTM is a registered Trademark of the RCABC.
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.