|
|
Line 1: |
Line 1: |
− | Manufacturer: <b>ADMIRAL ROOFING LTD.</b>
| + | [[Materials: Admiral AR9150 Mechanical Lock|AR9150 Mechanical Lock]] |
| | | |
− | Contact Address: See Membership List in Section 1.
| + | [[Materials:Admiral AR5150 SNAP LOCK PANEL|AR5150 Snap Lock]] |
| | | |
− | Product Group: <b>STANDING SEAM METAL ROOF SYSTEM - AR5150 SNAP LOCK PANEL</b>
| + | [[Materials:Admiral AR5150 NAIL STRIP PANEL|AR5150 Nail Strip]] |
− | | |
− | ;DESCRIPTION
| |
− | | |
− | The AR5150 Snap Lock panel is formed with an on-site / in-shop continuous metal roofing panel roll forming machine (Schlebach Quadro+). This machine produces a Snap-lock panel with a seam height of 38 mm (1-1/2") and profiles can vary from 200 mm (8") wide up to 500 mm (20") wide. This machine also produces a Nail-strip panel and a mechanically seamed panel.
| |
− | | |
− | On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities in lengths up to nominal 46 m (150').
| |
− | | |
− | ;1.1 <u>GENERAL</u>
| |
− | :The roofing assembly / material information published in the <b>RCABC <i>Roofing Practices Manual</i></b> DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority.
| |
− | | |
− | ;1.2 <u>SYSTEM DESCRIPTION</u>
| |
− | :.1 The AR5150 SL panel is a snap-lock concealed fastener roofing panel. The panel is attached with a hidden roof deck panel clip fastened to the acceptable substrate. The overlying panel (female rib) locks together with the underlying panel’s intergraded clip (male) and roof deck panel clips. The maximum spacing of the clips is 600 mm (24") on centre.
| |
− | :.2 Range of application: on wood or metal sloped roofs; in commercial, institutional, industrial and residential construction; for re-roofing or new construction.
| |
− | :.3 Panel Attachment:
| |
− | ::<b>Fasteners (Screws)</b> - Fasteners used to attach panels to plywood to be No. 10-12 by 25 mm (1") long pancake head wood screws. Minimum two fasteners per clip to be used.
| |
− | ::<b> Roof Deck Fasteners (Panel Clips)</b> - One piece assembly 57.15 mm (2-1/4") wide, 38 mm (1-1/2") high, minimum thickness 0.036" (No. 20 MSG). Clips spaced maximum 600 mm (24") on centre, fastened to the roof deck.
| |
− | | |
− | ;1.3 <u>SITE CONDITIONS</u>
| |
− | :.1 Minimum roof slope is 1:4 (3" in 12"). Severe conditions (heavy snow or ice) minimum slope is 1:1.5 (8" in 12").
| |
− | | |
− | ;1.4 <u>PERFORMANCE REQUIREMENTS</u>
| |
− | :.1 <u>Wind Uplift Standards</u>:
| |
− | ::National Research Council (NRC-CNRC) Report No.B1040 Wind Uplift Resistance of Metal Roofing. The NRC-CNRC Report No. B1040 test results confirm that an acceptable level of wind uplift resistance can be achieved with RGC Accepted Metal Panel Systems on typical roof designs over solid decking for most British Columbia geographical locations. Refer to Appendix II for calculations for typical roof wind uplift pressure requirements for buildings located in the Province of British Columbia.
| |
− | | |
− | ::A simplified design procedure developed by NRC-CNRC for selecting wind pressure calculations for metal roof assemblies by region (location) and building height in the Province of British Columbia is provided in TAB 8.1.5 to assist designers.
| |
− | | |
− | ::RGC accepted metal panel systems shall be formed of steel conforming to one of the following material specifications, as applicable:
| |
− | | |
− | ::* ASTM Standard Specification A653 / A653M, Sheet Steel, Zinc-Coated (Galvanized) or Zinc-Iron Alloy Coated (Galvannealed) by the hot dip process, minimum Grade 33, with a design thickness of 24 gauge. (0.024") or greater and a minimum zinc coating designation Z275 (G-90).
| |
− | ::* ASTM Standard Specification A792 / A792M, Steel Sheet, 55% Aluminum-Zinc Alloy-Coated by the Hot-Dip Process, minimum Grade 33, with a design thickness of 24 gauge (0.024") or greater and minimum coating designation AZ150.
| |
− | | |
− | <hr>
| |
− | | |
− | Manufacturer: <b>ADMIRAL ROOFING LTD.</b>
| |
− | | |
− | Contact Address: See Membership List in Section 1.
| |
− | | |
− | Product Group: <b>STANDING SEAM METAL ROOF SYSTEM - AR5150 NAIL STRIP PANEL</b>
| |
− | | |
− | ;DESCRIPTION
| |
− | | |
− | The AR5 150 Nail Strip panel is formed with an on-site / in-shop continuous metal roofing panel roll forming machine (Schlebach Quadro+). This machine produces a Nail-strip panel with a seam height of 38 mm (1½") and profiles can vary from 200 mm (8") wide up to 637.5 mm (25½") wide . This machine also produces a Snap-lock panel and a mechanically seamed panel.
| |
− | | |
− | On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities in lengths up to nominal 46 m (150').
| |
− | | |
− | ;1.1 GENERAL
| |
− | :The roofing assembly / material information published in the <b>RCABC <i>Roofing Practices Manual</i></b> does NOT represent a complete set of the manufacturer’s published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority.
| |
− | | |
− | ;1.2 SYSTEM DESCRIPTION
| |
− | :.1 The AR5150 NS panel is a snap-lock concealed fastener roofing panel. The panel is fastened to the acceptable substrate along the integrated fastening strip along the entire length of the panel. The overlying panel (female rib) locks together with the underlying panel’s integrated clip (male), along the entire length of the panel. The maximum spacing of the fasteners is 600 mm (24") on centre.
| |
− | :.2 Range of application: on wood or metal sloped roofs; in commercial, institutional, industrial and residential construction; for re-roofing or new construction.
| |
− | :.3 Panel Attachment:
| |
− | ::<b>Fasteners (Screws)</b> - Fasteners used to attach panels to plywood to be No. 10-12 by 25 mm (1") long pancake head wood screws.
| |
− | | |
− | ;1.3 SITE CONDITIONS
| |
− | .1 Minimum roof slope is 1:4 (3" in 12"). Severe conditions (heavy snow or ice) minimum slope is 1:1.5 (8" in 12").
| |
− | | |
− | <hr>
| |
− | | |
− | Manufacturer: <b>ADMIRAL ROOFING LTD.</b>
| |
− | | |
− | Contact Address: See Membership List in Section 1.
| |
− | | |
− | Product Group: <b>STANDING SEAM METAL ROOF SYSTEM - AR9150</b>
| |
− | | |
− | ;DESCRIPTION
| |
− | | |
− | :The AR9150 standing seam panel is formed with an on-site/in-shop continuous metal roofing panel roll forming machine (Schlebach Quadro+). This machine produces a standing seam panel with a seam height of 38 mm (1½") and profiles can vary from 200 mm (8") wide up to 652.5 mm (26½") wide. This machine also produces a Nail-strip panel and a Snap-lock panel.
| |
− | | |
− | :On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities in lengths up to nominal 46 m (150').
| |
− | | |
− | ;1.1 <u>GENERAL</u>
| |
− | :The roofing assembly / material information published in the <b>RGC </b><b><i>Roofing Practices Manual</i></b> does NOT represent a complete set of the manufacturer’s published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority.
| |
− | | |
− | ;1.2 <u>SYSTEM DESCRIPTION</u>
| |
− | :.1 The AR9150 panel is a standing seam concealed fastener roofing panel. The panel is attached with a hidden roof deck panel clip fastened to the acceptable substrate. The panels are seamed together with a mechanical seamer. The maximum spacing of the clips is 600 mm (24") on centre.
| |
− | :.2 Range of application: on wood or metal sloped roofs; in commercial, institutional, industrial and residential construction; for re-roofing or new construction.
| |
− | :.3 Panel Attachment:
| |
− | :;Fasteners (Screws)
| |
− | ::Fasteners used to attach panels to plywood to be No. 10-12 by 25 mm (1") long pancake head wood screws. Minimum two fasteners per clip to be used.
| |
− | | |
− | ;Roof Deck Fasteners (Panel Clips)
| |
− | ::Two piece assembly consisting of steel base approx 25 mm (1") wide x 150 mm (6") long, minimum thickness of 0.036" (No. 20 MSG) and an upper tab, 41 mm (1<sup>5</sup>/<sub>8</sub>") high, minimum thickness of 0.020" (No. 26 MSG). One panel clip spaced at 600 mm (24") on centre maximum.
| |
− | | |
− | ;1.3 <u>SITE CONDITIONS</u>
| |
− | :.1 Minimum roof slope is 1:4 (3" in 12"). Severe conditions (heavy snow or ice) minimum slope is 1:1.5 (8" in 12").
| |
− | | |
− | <hr>
| |
− | | |
− | | |
− | | |
− | [[Accepted Materials - ASM Roofing|<i class="fa fa-chevron-circle-left fa-2x" ></i> Back to ''Accepted Materials - ASM Roofing'']]
| |
− | | |
− | [[Section:E. Application: Steep Slope Roofs|<i class="fa fa-chevron-circle-left fa-2x" ></i> Back to ''Application: Steep Slopes'']]
| |