Difference between revisions of "Materials:LiveRoof Lite System Conventional Roof"
Difference between revisions of "Materials:LiveRoof Lite System Conventional Roof"
| Line 1: | Line 1: | ||
| − | :< | + | __NOTOC__ |
| + | __NONUMBEREDHEADINGS__ | ||
| + | {{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}} | ||
| − | :<big> | + | <big><big>Division C - Accepted Materials</big></big> |
| + | <br> | ||
| + | <big>Group - Vegetated Roof Systems</big> | ||
| + | <hr> | ||
| + | <big><big><big><big><big>LiveRoof® Lite System (Conventional Roof)</big></big></big></big></big><br> | ||
| + | <big><big><big>by LiveRoof LLC</big></big></big><br> | ||
| + | {| class="wikitable" | ||
| + | |- | ||
| + | | style="background-color:#FFFACD" | '''<big>System/Material Acceptance and Product Details</big>''' | ||
| + | <br> | ||
| + | The information published in the RCABC '''''Roofing Practices Manual''''' and offered below does NOT represent a complete set of the manufacturer’s data or specifications, nor is this system and its various materials recommended or endorsed by the '''''Guarantor'''''. The preparation of a detailed specification is the responsibility of the ''Design Authority''. | ||
| + | |- | ||
| + | | | ||
| + | <div class="col-md-12"> | ||
| + | <div class="col-md-6"> | ||
| + | ;: | ||
| + | ;'''Vegetated Roof System Manufacturer''': [https://liveroof.com/ '''LiveRoof LLC'''] | ||
| + | ;Accepted for the ''RoofStar Guarantee Program'': January 20, 2026 | ||
| + | ;Accepted for application in: Vegetated Roof Systems | ||
| + | ;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]] | ||
| + | ;System Summary: The '''LiveRoof Lite System''' for ''conventionally insulated roof assemblies'' is typically used on retrofit projects when the roof is engineered with only 15 to 17 pounds per sf for the green roof component. Its soil depth is a full 2 ½ inches, enough to support many low growing succulents and a limited number of accent plants. It is generally not recommended for hot climates. | ||
| − | ::- Roofing Practices Manual | + | :The '''LiveRoof Lite System''' provides a modest level of storm water management and may provide modest energy savings, especially if attentively irrigated during the warm season. It also meets greenspace requirements in many instances, and provides limited biodiversity. Its plants will support pollinators such as butterflies and honeybees, and the plants that grow in the Lite System are diverse enough to support patterned designs. |
| + | |||
| + | :The plants used in the '''LiveRoof Lite System''' include a fairly broad range of low growing Sedums (mostly fine and medium-textured), as well as a few Alliums, for vertical and textural interest. | ||
| + | :(adapted from the manufacturer's literature) | ||
| + | <br> | ||
| + | <div style="text-align: left;"> | ||
| + | [[File:Extensive VR System (banner).JPG| left | class=img-responsive | link=]] | ||
| + | </div> | ||
| + | </div> | ||
| + | <div class="col-md-6"> | ||
| + | ;: | ||
| + | ;Manufacturer online resources: [https://liveroof.com/products/modules/#lite LiveRoof Lite System] | ||
| + | ;System Type: Extensive | ||
| + | ;System Depth: Varies with plant profile | ||
| + | ;Growing Media Depth: 6.35 cm (2-1/2") | ||
| + | ;Vegetation Profile: A mixture of climate specific moss-sedums | ||
| + | ;Suitable climate zones: All BC zones, subject to manufacturer's approval | ||
| + | ;System Components<sup>*</sup>: In the usual order, from top to bottom; click on link for Technical Data Sheet (TDS) or product drawing (not all components are supported by a TDS) | ||
| + | :{| class="wikitable" | ||
| + | |- | ||
| + | | | ||
| + | [https://rpm.rcabc.org/images/5/52/LiveRoof_System_Properties_TDS.pdf '''LiveRoof Lite (Conventional) Properties'''] (TDS) | ||
| + | * '''Vegetation''' (Consult LiveRoof LLC for available plant profiles) | ||
| + | *'''LiveRoof® Engineered Growing Media''' (Consult LiveRoof LLC for precise blend specifications) | ||
| + | *[https://rpm.rcabc.org/images/c/c8/LiveRoof_WindDics_TDS.pdf '''WindDisc™'''] (TDS) | ||
| + | *[https://rpm.rcabc.org/images/a/a7/LiveRoof_%28Lite%29_Conventional_Assembly_Drawing.pdf '''LiveRoof® Lite Module (Conventional)'''] (Drawing) | ||
| + | *[https://rpm.rcabc.org/images/f/f3/LiveRoof_Blue_Retain%2C_Detain_TDS.pdf '''RoofBlue® Retain/Detain'''] (TDS) | ||
| + | *[https://rpm.rcabc.org/images/9/99/LiveRoof_%28Lite%29_Blue_Retain_Drawing.pdf '''RoofBlue® Retain '''] (Drawing) | ||
| + | *[https://rpm.rcabc.org/images/3/3c/LiveRoof_%28Lite%29_Blue_Detain_Drawing.pdf '''RoofBlue® Detain '''] (Drawing) | ||
| + | *[https://rpm.rcabc.org/images/1/11/LiveRoof_PipeRunner_Drawing.pdf '''PipeRunner™'''] (Drawing) | ||
| + | *[https://rpm.rcabc.org/images/9/97/LiveRoof_Anchor_%28Tie-off%29_Drawing.pdf '''RoofEdge® Aluminum Tie-off Box'''] (Drawing) | ||
| + | *[https://rpm.rcabc.org/images/5/51/LiveRoof_Drain_Box_Drawing.pdf '''RoofEdge® Aluminum Drain'''] (Drawing) | ||
| + | *[https://rpm.rcabc.org/images/2/28/LiveRoof_%28Lite%29_RoofEdge_Aluminum_Edge_Drawing.pdf '''RoofEdge® Aluminum Edging'''] (Drawing) | ||
| + | *[https://rpm.rcabc.org/images/a/ad/LiveRoof_RoofStone_Specification.pdf '''RoofStone™ Paver '''] (Specification) | ||
| + | *'''Root Barrier''' (supplied by roof membrane manufacturer) | ||
| + | |} | ||
| + | </div> | ||
| + | <div class="col-md-12"> | ||
| + | <hr> | ||
| + | <div class="col-md-6"> | ||
| + | |||
| + | ;<sup>†</sup>Guarantor's Notes: Systems labeled "Inverted" are designed for a ''protected membrane roof assembly'', also known as an inverted ''roof assembly''. | ||
| + | |||
| + | :While ''Semi-intensive'' and ''Intensive vegetated roof systems'' are limited to only ''protected membrane roofs'' (See the [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.2._Permitted_Vegetated_Roof_Systems Sentence 1.1.3.2.(5)] in the "RGC Standard for Vegetated Roofs"), some vegetated roof system manufacturers offer their systems for ''conventionally insulated roofs''. To request a written Variance to the published limitation, follow the requirements in [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.6._Variances Article 1.1.3.6.]. | ||
| + | |||
| + | </div> | ||
| + | <div class="col-md-6"> | ||
| + | |||
| + | ;<sup>*</sup>Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements. Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight. | ||
| + | |||
| + | :Also note that vegetation coverage under the '''''RoofStar Vegetated Roof Guarantee''''' applies only to ''extensive systems'' planted with mats or trays - see [https://rpm.rcabc.org/index.php?title=Guarantee Part 3] of Division A for more about coverage. | ||
| + | |||
| + | </div> | ||
| + | </div> | ||
| + | <div class="col-md-12"> | ||
| + | <br> | ||
| + | |} | ||
| + | |||
| + | <hr> | ||
| + | |||
| + | [[Division C: Accepted Materials|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Accepted Materials'']] | ||
| + | |||
| + | [[RCABC Roofing Practices Manual|Home]] | ||
Revision as of 23:24, 11 February 2026
Division C - Accepted Materials
Group - Vegetated Roof Systems
LiveRoof® Lite System (Conventional Roof)
by LiveRoof LLC
| System/Material Acceptance and Product Details
| |
|
