Difference between revisions of "Materials:ZinCo Roof Garden Assembly (Inverted)"
Difference between revisions of "Materials:ZinCo Roof Garden Assembly (Inverted)"
(Created page with "__NOTOC__ __NONUMBEREDHEADINGS__ {{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}} <big>...") |
|||
| Line 23: | Line 23: | ||
;Accepted for application in: Vegetated Roof Systems | ;Accepted for application in: Vegetated Roof Systems | ||
;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]] | ;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]] | ||
| − | ;System Summary: | + | ;System Summary: ZinCo Canada's '''Roof Garden Assembly''' is designed as a multifunctional green roof with a high capacity for water retention, allowing you to include a wider variety of plants. ZinCo's Roof Garden Assembly Features: |
| + | :*Supports lawns, perennials, shrubs and even trees | ||
| + | :*Can include paths, terraces, driveways or playgrounds | ||
| + | :*Structures can be built directly on the Floradrain® FD 60 system, without penetrating the roof membrane or impairing the drainage. | ||
| + | :(adapted from the manufacturer's literature) | ||
| + | <sup>†</sup>Systems labeled "Inverted" are designed for a ''protected membrane roof assembly'', also known as an inverted ''roof assembly''. While ''Semi-intensive'' and ''Intensive vegetated roof systems'' are limited to only ''protected membrane roofs'' (See the [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.2._Permitted_Vegetated_Roof_Systems Sentence 1.1.3.2.(5)] in the "RGC Standard for Vegetated Roofs"), some vegetated roof system manufacturers offer their systems for ''conventionally insulated roofs''. To request a written Variance to the published limitation, follow the requirements in [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.6._Variances Article 1.1.3.6.]. | ||
<div style="text-align: left;"> | <div style="text-align: left;"> | ||
[[File:Extensive VR System (sedum tile).jpg| left | 450 px| link=]] | [[File:Extensive VR System (sedum tile).jpg| left | 450 px| link=]] | ||
| Line 30: | Line 35: | ||
<div class="col-md-6"> | <div class="col-md-6"> | ||
;: | ;: | ||
| − | ;Manufacturer Online Resource: [ | + | ;Manufacturer Online Resource: [https://www.zinco.ca/roof-garden ZinCo Roof Garden] |
| − | ;System Depth: | + | ;System Type: Intensive |
| − | ;Growing Media Depth: | + | ;System Depth: 241.3 mm (9-1/2") to 260.35 mm (10-1/4") |
| − | ;Vegetation Profile: | + | ;Growing Media Depth: 203.1 mm (8") to 203.1 mm (8") |
| − | ;Suitable climate zones: | + | ;Vegetation Profile: Sedums-Perennials-Grasses-Herbacious |
| − | ;System Components: | + | ;Suitable climate zones: All BC zones, subject to manufacturer's approval |
| − | + | ;System Components<sup>*</sup>: In the usual order, from top to bottom; click on link for Technical Data Sheet (TDS) | |
| − | : | + | :*'''Perennials-Grasses-Herbacious-Sedums''' (See pre-grown vegetation by ZinCo Canada) or as specified by the ''Design Authority''/''Green Roof Design Professional'' (See Conditions and Limitations below) |
| − | : | + | :*[https://rpm.rcabc.org/images/a/a3/ZinCo_System_Growing_Medium_%28ZinCo_Blend-SI%29_TDS.pdf '''Growing Medium Blend-SI'''] |
| − | : | + | :*[https://rpm.rcabc.org/images/9/91/ZinCo_Filter_Sheet_SF_TDS.pdf '''Filter Sheet SF'''] |
| − | : | + | :*[https://rpm.rcabc.org/images/6/62/ZinCo_Floradrain_FD40-E_TDS.pdf '''Floradrain FD40-E'''] |
| + | :**[https://rpm.rcabc.org/images/7/75/ZinCo_Floradrain_FD25-E_TDS.pdf '''Floradrain FD25-E'''] (alternate drainage board) | ||
| + | :**[https://rpm.rcabc.org/images/3/3d/ZinCo_Drainage_Mat_DBV10_TDS.pdf '''DBV-10'''] (alternate drainage board) | ||
| + | :*[https://rpm.rcabc.org/images/4/40/ZinCo_Separation_Membrane_TGV21_TDS.pdf '''TGV 21 Diffusion Membrane'''] | ||
| + | ::'''XPS Insulation''' by roofing ''Contractor'' (Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]]) | ||
| + | :*[https://rpm.rcabc.org/images/0/09/ZinCo_Root_Barrier_WSF40_TDS.pdf '''Root Barrier WSF40'''] | ||
| + | ::'''Waterproofing Roof Assembly''' (membrane) by roofing ''Contractor'' | ||
;<sup>*</sup>Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements. Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight. | ;<sup>*</sup>Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements. Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight. | ||
Revision as of 18:54, 27 November 2024
Division C - Accepted Materials
Group - Vegetated Roof Systems
ZinCo Roof Garden Assembly (Inverted†)
by ZinCo Canada Inc.
| System/Material Acceptance and Product Details
|
†Systems labeled "Inverted" are designed for a protected membrane roof assembly, also known as an inverted roof assembly. While Semi-intensive and Intensive vegetated roof systems are limited to only protected membrane roofs (See the Sentence 1.1.3.2.(5) in the "RGC Standard for Vegetated Roofs"), some vegetated roof system manufacturers offer their systems for conventionally insulated roofs. To request a written Variance to the published limitation, follow the requirements in Article 1.1.3.6..
|