Difference between revisions of "Materials:NLSM LiteN'Less II"
Difference between revisions of "Materials:NLSM LiteN'Less II"
Line 24: | Line 24: | ||
;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]] | ;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]] | ||
;System Summary: The '''LiteN’Less™ II''' system is Next Level Stormwater Management's lightest vegetated system available. Lightweight and soilless, with no “loose” growing medium, its light weight avoids excessive loading and is therefore offered as a solution for roof retrofits (adapted from the manufacturer's literature). | ;System Summary: The '''LiteN’Less™ II''' system is Next Level Stormwater Management's lightest vegetated system available. Lightweight and soilless, with no “loose” growing medium, its light weight avoids excessive loading and is therefore offered as a solution for roof retrofits (adapted from the manufacturer's literature). | ||
− | <div style="text-align:left;"> | + | <div style="text-align: left;"> |
− | [[File:Extensive VR System ( | + | [[File:Extensive VR System (banner).JPG| left | class=img-responsive | link=]] |
</div> | </div> | ||
</div> | </div> | ||
Line 35: | Line 35: | ||
;Vegetation Profile: Moss-Sedum | ;Vegetation Profile: Moss-Sedum | ||
;Suitable climate zones: All BC zones except Zone 4, subject to manufacturer's approval | ;Suitable climate zones: All BC zones except Zone 4, subject to manufacturer's approval | ||
− | ;System Components: | + | ;System Components<sup>*</sup>: In the usual order, from top to bottom; click on link for Technical Data Sheet (TDS) |
− | : | + | :{| class="wikitable" |
− | + | |- | |
− | + | | | |
− | :''' | + | *[https://rpm.rcabc.org/images/b/bd/NLSM_NL718_Sedum_Blanket_-_Standard_Mix_BC_TDS.pdf '''NL718 Sedum Blanket'''] |
− | :''' | + | *[https://rpm.rcabc.org/images/a/a7/NLSM_NL512_Retention_Fleece_TDS.pdf '''NL512 Retention Fleece'''] |
− | + | **'''NL512 Retention Fleece''' (Note that this system requires two (2) layers of fleece) | |
− | + | :'''XPS Insulation''' by roofing ''Contractor'' (Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]]) | |
− | + | *[https://rpm.rcabc.org/images/3/32/NLSM_NL120_Root_Barrier_TDS.pdf '''NL120 Root Barrier'''] | |
+ | :'''Waterproofing Roof Assembly''' (membrane) by roofing ''Contractor'' | ||
+ | *[https://rpm.rcabc.org/images/9/96/NLSM_NL200_Edging_and_Accessories_TDS.pdf '''NL200 Edging & Accessories'''] | ||
+ | *'''NL210 Drain Box & Accessories''' | ||
+ | *'''NL220 Penetration Box''' | ||
+ | *'''NL WindProtect Plate''' | ||
+ | |} | ||
+ | </div> | ||
+ | <div class="col-md-12"> | ||
+ | <hr> | ||
+ | <div class="col-md-6"> | ||
+ | |||
+ | ;<sup>†</sup>Guarantor's Notes: Systems labeled "Inverted" are designed for a ''protected membrane roof assembly'', also known as an inverted ''roof assembly''. | ||
+ | |||
+ | :While ''Semi-intensive'' and ''Intensive vegetated roof systems'' are limited to only ''protected membrane roofs'' (See the [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.2._Permitted_Vegetated_Roof_Systems Sentence 1.1.3.2.(5)] in the "RGC Standard for Vegetated Roofs"), some vegetated roof system manufacturers offer their systems for ''conventionally insulated roofs''. To request a written Variance to the published limitation, follow the requirements in [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.6._Variances Article 1.1.3.6.]. | ||
+ | |||
+ | </div> | ||
+ | <div class="col-md-6"> | ||
;<sup>*</sup>Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements. Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight. | ;<sup>*</sup>Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements. Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight. | ||
:Also note that vegetation coverage under the '''''RoofStar Vegetated Roof Guarantee''''' applies only to ''extensive systems'' planted with mats or trays - see [https://rpm.rcabc.org/index.php?title=Guarantee Part 3] of Division A for more about coverage. | :Also note that vegetation coverage under the '''''RoofStar Vegetated Roof Guarantee''''' applies only to ''extensive systems'' planted with mats or trays - see [https://rpm.rcabc.org/index.php?title=Guarantee Part 3] of Division A for more about coverage. | ||
+ | |||
</div> | </div> | ||
</div> | </div> |
Revision as of 15:56, 29 November 2024
Division C - Accepted Materials
Group - Vegetated Roof Systems
NLSM LiteN'Less II
by Next Level Stormwater Management
System/Material Acceptance and Product Details
| |
|