Difference between revisions of "Materials:NLSM LiteN'Less III"

Jump to: navigation, search

Difference between revisions of "Materials:NLSM LiteN'Less III"

Line 24: Line 24:
 
;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]]
 
;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]]
 
;System Summary: The '''LiteN’Less™ III''' system is lightweight and soilless, with no “loose” growing medium, and utilizes three layers of water retention fleece while still offering solutions for roof retrofits (adapted from the manufacturer's literature).
 
;System Summary: The '''LiteN’Less™ III''' system is lightweight and soilless, with no “loose” growing medium, and utilizes three layers of water retention fleece while still offering solutions for roof retrofits (adapted from the manufacturer's literature).
<div style="text-align:left;">
+
<div style="text-align: left;">
[[File:Extensive VR System (sedum tile).jpg| left | 450 px| link=]]
+
[[File:Extensive VR System (banner).JPG| left | class=img-responsive | link=]]
 
</div>
 
</div>
 
</div>
 
</div>
Line 35: Line 35:
 
;Vegetation Profile: Moss-Sedum
 
;Vegetation Profile: Moss-Sedum
 
;Suitable climate zones: All BC zones except Zone 4, subject to manufacturer's approval
 
;Suitable climate zones: All BC zones except Zone 4, subject to manufacturer's approval
;System Components:
+
;System Components<sup>*</sup>: In the usual order, from top to bottom; click on link for Technical Data Sheet (TDS)
:'''NL718 Sedum Blanket''' (Click [https://rpm.rcabc.org/images/b/bd/NLSM_NL718_Sedum_Blanket_-_Standard_Mix_BC_TDS.pdf here] for the Technical Data Sheet PDF)
+
:{| class="wikitable"
:'''NL512 Retention Fleece''' (Click [https://rpm.rcabc.org/images/a/a7/NLSM_NL512_Retention_Fleece_TDS.pdf here] for the Technical Data Sheet PDF)
+
|-
:'''NL512 Retention Fleece'''
+
|
:'''NL512 Retention Fleece''' (Note that this system requires three (3) layers of fleece)
+
*[https://rpm.rcabc.org/images/b/bd/NLSM_NL718_Sedum_Blanket_-_Standard_Mix_BC_TDS.pdf '''NL718 Sedum Blanket''']
:'''NL300 Drainage Mat''' (Conventional Roof) (Click [https://rpm.rcabc.org/images/4/40/NLSM_NL300_Drainage_Mat_TDS.pdf here] for the Technical Data Sheet PDF) or Stone Ballast (PMRA)
+
*[https://rpm.rcabc.org/images/a/a7/NLSM_NL512_Retention_Fleece_TDS.pdf '''NL512 Retention Fleece''']
:'''NL120 Root Barrier''' (Click [https://rpm.rcabc.org/images/3/32/NLSM_NL120_Root_Barrier_TDS.pdf here] for the Technical Data Sheet PDF)
+
**'''NL512 Retention Fleece''' (Note that this system requires two (2) layers of fleece)
:'''NL200 Edging & Accessories''' (Click [https://rpm.rcabc.org/images/9/96/NLSM_NL200_Edging_and_Accessories_TDS.pdf here] for the Technical Data Sheet PDF)
+
*[https://rpm.rcabc.org/images/4/40/NLSM_NL300_Drainage_Mat_TDS.pdf '''NL300 Drainage Mat''' (Conventional Roof)] or Stone Ballast (PMRA)
:'''NL210 Drain Box & Accessories'''
+
*[https://rpm.rcabc.org/images/3/32/NLSM_NL120_Root_Barrier_TDS.pdf '''NL120 Root Barrier''']
:'''NL220 Penetration Box'''
+
:'''Conventionally Insulated Roof Assembly''' by roofing ''Contractor''
 +
*[https://rpm.rcabc.org/images/9/96/NLSM_NL200_Edging_and_Accessories_TDS.pdf '''NL200 Edging & Accessories''']
 +
*'''NL210 Drain Box & Accessories'''
 +
*'''NL220 Penetration Box'''
 +
|}
 +
</div>
 +
<div class="col-md-12">
 +
<hr>
 +
<div class="col-md-6">
 +
 
 +
;<sup>†</sup>Guarantor's Notes: Systems labeled "Inverted" are designed for a ''protected membrane roof assembly'', also known as an inverted ''roof assembly''.
 +
 
 +
:While ''Semi-intensive'' and ''Intensive vegetated roof systems'' are limited to only ''protected membrane roofs'' (See the [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.2._Permitted_Vegetated_Roof_Systems Sentence 1.1.3.2.(5)] in the "RGC Standard for Vegetated Roofs"), some vegetated roof system manufacturers offer their systems for ''conventionally insulated roofs''.  To request a written Variance to the published limitation, follow the requirements in [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.6._Variances Article 1.1.3.6.].
 +
 
 +
</div>
 +
<div class="col-md-6">
  
 
;<sup>*</sup>Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements.  Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight.
 
;<sup>*</sup>Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements.  Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight.
  
 
:Also note that vegetation coverage under the '''''RoofStar Vegetated Roof Guarantee''''' applies only to ''extensive systems'' planted with mats or trays - see [https://rpm.rcabc.org/index.php?title=Guarantee Part 3] of Division A for more about coverage.
 
:Also note that vegetation coverage under the '''''RoofStar Vegetated Roof Guarantee''''' applies only to ''extensive systems'' planted with mats or trays - see [https://rpm.rcabc.org/index.php?title=Guarantee Part 3] of Division A for more about coverage.
 +
 
</div>
 
</div>
 
</div>
 
</div>

Revision as of 16:41, 29 November 2024



Division C - Accepted Materials
Group - Vegetated Roof Systems


NLSM LiteN'Less III
by Next Level Stormwater Management

System/Material Acceptance and Product Details


The information published in the RCABC Roofing Practices Manual and offered below does NOT represent a complete set of the manufacturer’s data or specifications, nor is this system and its various materials recommended or endorsed by the Guarantor. The preparation of a detailed specification is the responsibility of the Design Authority.

Vegetated Roof System Manufacturer
Name linked to website here
Accepted for the RoofStar Guarantee Program
October 25, 2024
Accepted for application in
Vegetated Roof Systems
Acceptance Criteria
Refer to the RGC Standard for Vegetated Roofs
System Summary
The LiteN’Less™ III system is lightweight and soilless, with no “loose” growing medium, and utilizes three layers of water retention fleece while still offering solutions for roof retrofits (adapted from the manufacturer's literature).
Extensive VR System (banner).JPG
Manufacturer Online Resource
LiteN'Less III System
System Depth
45.0 mm (1-13/16") to 62.0 mm (2-7/16")
Growing Media Depth
20 mm (13/16")
Vegetation Profile
Moss-Sedum
Suitable climate zones
All BC zones except Zone 4, subject to manufacturer's approval
System Components*
In the usual order, from top to bottom; click on link for Technical Data Sheet (TDS)
Conventionally Insulated Roof Assembly by roofing Contractor

Guarantor's Notes
Systems labeled "Inverted" are designed for a protected membrane roof assembly, also known as an inverted roof assembly.
While Semi-intensive and Intensive vegetated roof systems are limited to only protected membrane roofs (See the Sentence 1.1.3.2.(5) in the "RGC Standard for Vegetated Roofs"), some vegetated roof system manufacturers offer their systems for conventionally insulated roofs. To request a written Variance to the published limitation, follow the requirements in Article 1.1.3.6..
*Conditions and Limitations
Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements. Consult with the vegetated roof system manufacturer for options and saturated system weight.
Also note that vegetation coverage under the RoofStar Vegetated Roof Guarantee applies only to extensive systems planted with mats or trays - see Part 3 of Division A for more about coverage.



Back to Accepted Materials