Difference between revisions of "Materials:NLSM StormCap Detain 3°"
Difference between revisions of "Materials:NLSM StormCap Detain 3°"
Line 24: | Line 24: | ||
;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]] | ;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]] | ||
;System Summary: '''StormCap™ Detain 3°''' is designed to manage stormwater on the roof by providing retention and detention, making it a full-fledged stormwater tool ready to face second day and extra-large storms. '''StormCap™ Detain 3°''' reduces or eliminates the need for cisterns and bioretention facilities and frees up valuable space for income-generating development. It is also designed to work on sloped roofs (adapted from the manufacturer's literature). | ;System Summary: '''StormCap™ Detain 3°''' is designed to manage stormwater on the roof by providing retention and detention, making it a full-fledged stormwater tool ready to face second day and extra-large storms. '''StormCap™ Detain 3°''' reduces or eliminates the need for cisterns and bioretention facilities and frees up valuable space for income-generating development. It is also designed to work on sloped roofs (adapted from the manufacturer's literature). | ||
− | <div style="text-align:left;"> | + | <div style="text-align: left;"> |
− | [[File:Extensive VR System ( | + | [[File:Extensive VR System (banner).JPG| left | class=img-responsive | link=]] |
</div> | </div> | ||
</div> | </div> | ||
Line 31: | Line 31: | ||
;: | ;: | ||
;Manufacturer Online Resource: [https://www.nlsm.ca/systems-technical-info-2/extensive-systems/detention/ StormCap Detain 3° System] | ;Manufacturer Online Resource: [https://www.nlsm.ca/systems-technical-info-2/extensive-systems/detention/ StormCap Detain 3° System] | ||
+ | ;System Type: Extensive | ||
;System Depth: 114 mm (4-1/2") to 352 mm (13-7/8") | ;System Depth: 114 mm (4-1/2") to 352 mm (13-7/8") | ||
;Growing Media Depth: 70 mm (2-3/4") to 170 mm (6-11/16") | ;Growing Media Depth: 70 mm (2-3/4") to 170 mm (6-11/16") | ||
;Vegetation Profile: Moss-Sedum | ;Vegetation Profile: Moss-Sedum | ||
;Suitable climate zones: All BC zones, subject to manufacturer's approval | ;Suitable climate zones: All BC zones, subject to manufacturer's approval | ||
− | ;System Components: | + | ;System Components<sup>*</sup>: In the usual order, from top to bottom; click on link for Technical Data Sheet (TDS) |
− | :'''NL718 Sedum Blanket''' | + | :{| class="wikitable" |
− | + | |- | |
− | + | | | |
− | + | *[https://rpm.rcabc.org/images/b/bd/NLSM_NL718_Sedum_Blanket_-_Standard_Mix_BC_TDS.pdf '''NL718 Sedum Blanket'''] | |
− | + | *[https://rpm.rcabc.org/images/2/25/NLSM_NL600_Growing_Medium_HOM_-_BC_G_TDS.pdf '''NL600 Growing Medium'''] | |
− | + | *[https://rpm.rcabc.org/images/6/61/NLSM_NL501_Needled_Mineral_Hydro_Blanket_TDS.pdf '''NL501 NM Hydro Blanket'''] (thickness varies from 2.5 to 7.5 cm) | |
− | :'''NL201 Non-Perforated Edging''' | + | *[https://rpm.rcabc.org/images/e/e3/NLSM_NL351_Reservoir_Cell_TDS.pdf '''NL351 Reservoir Cell'''] (thickness varies from 1.25 to 10 cm) |
− | + | *[https://rpm.rcabc.org/images/1/1e/NLSM_NL350_Detention_Mat_TDS.pdf '''NL350 Detention Mat'''] | |
+ | *[https://rpm.rcabc.org/images/3/32/NLSM_NL120_Root_Barrier_TDS.pdf '''NL120 Root Barrier'''] | ||
+ | :'''Conventionally Insulated Roof Assembly''' by roofing ''Contractor'' | ||
+ | *'''NL201 Non-Perforated Edging''' | ||
+ | *'''NL211 Drainbox''' | ||
+ | |} | ||
+ | |||
+ | </div> | ||
+ | <div class="col-md-12"> | ||
+ | <hr> | ||
+ | <div class="col-md-6"> | ||
+ | |||
+ | ;<sup>†</sup>Guarantor's Notes: Systems labeled "Inverted" are designed for a ''protected membrane roof assembly'', also known as an inverted ''roof assembly''. | ||
+ | |||
+ | :Note that perforated edge metal is required in the "RGC Standard for Vegetated Roofs"; therefore, when a system specifies materials that do not conform to the Standard, the ''Design Authority'' must request a written Variance from the '''''Guarantor'''''. | ||
+ | |||
+ | :In addition, while ''Semi-intensive'' and ''Intensive vegetated roof systems'' are limited to only ''protected membrane roofs'' (See the [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.2._Permitted_Vegetated_Roof_Systems Sentence 1.1.3.2.(5)] in the "RGC Standard for Vegetated Roofs"), some vegetated roof system manufacturers offer their systems for ''conventionally insulated roofs''. To request a written Variance to the published limitation, follow the requirements in [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.6._Variances Article 1.1.3.6.]. | ||
+ | |||
+ | </div> | ||
+ | <div class="col-md-6"> | ||
;<sup>*</sup>Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements. Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight. | ;<sup>*</sup>Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements. Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight. | ||
:Also note that vegetation coverage under the '''''RoofStar Vegetated Roof Guarantee''''' applies only to ''extensive systems'' planted with mats or trays - see [https://rpm.rcabc.org/index.php?title=Guarantee Part 3] of Division A for more about coverage. | :Also note that vegetation coverage under the '''''RoofStar Vegetated Roof Guarantee''''' applies only to ''extensive systems'' planted with mats or trays - see [https://rpm.rcabc.org/index.php?title=Guarantee Part 3] of Division A for more about coverage. | ||
+ | |||
</div> | </div> | ||
</div> | </div> |
Revision as of 17:03, 29 November 2024
Division C - Accepted Materials
Group - Vegetated Roof Systems
NLSM StormCap Detain 3°
by Next Level Stormwater Management
System/Material Acceptance and Product Details
| |
|