Difference between revisions of "Working Page 10"

Jump to: navigation, search

Difference between revisions of "Working Page 10"

m
 
Line 6: Line 6:
 
<big><big><big><big><big>PVC | Expansion Joint (Field) ([[PVC_Roof_Systems_Standard#10.3.6.1._Expansion_Joints |Article 10.3.6.1.]])</big></big></big></big></big>
 
<big><big><big><big><big>PVC | Expansion Joint (Field) ([[PVC_Roof_Systems_Standard#10.3.6.1._Expansion_Joints |Article 10.3.6.1.]])</big></big></big></big></big>
 
{{Template:Construction Details Header}}
 
{{Template:Construction Details Header}}
−
<div class="panel panel-success">
+
<div class="panel panel-info">
 
<div class="panel-heading"><big>'''SBS Details'''</big></div>
 
<div class="panel-heading"><big>'''SBS Details'''</big></div>
 
<div class="panel-body">
 
<div class="panel-body">

Latest revision as of 15:36, 30 October 2026


Division D - Construction Details


PVC | Expansion Joint (Field) (Article 10.3.6.1.)

Notice to Reader
Images used in a Construction Detail are representative and not prescriptive, and are not necessarily drawn to scale. They are intended to support the related Standard (Ref. Division A, Article 2.2.1.2.).

The reader may link to the related Article in the detail title, or link to the Standard as it relates to a specific element in the detail. All hyperlinks are displayed blue text.

SBS Details

Part 10 - CD - Expansion Joints (Field) PVC.png

1 WORK INCLUDED

(1) Roof membrane
Waterproofs the expansion joint structure and provides a base layer for the control joint material to bond with.
(2) Expansion joint (elastomeric product illustrated)
This joint is proprietary to its manufacturer and will be fitted, manufactured, and installed (or its installation supervised) by others. Secured to substrate as required by manufacturer.
(3) Reinforced membrane strip
Applied to cover the control joint and seal it to the membrane system.
(4) Metal cap (coping) flashing
Fabricated and installed as required in Part 13.
(5) Metal counter-flashing
The counter-flashing below the cap flashing is secured independently of the metal cap flashing to permit movement of the expansion joint assembly across the planes of anticipated structural movement. Dimensions are project-specific.



2 RELATED WORK BY OTHERS

(A) Acceptable deck
(B) Expansion joint structure

NOTE: See the Standard for additional requirements.