  • ;(3) [[ASM Roof Systems Standard#PART_7|'''Insulation''']]: Offset and stagger layers 300 mm (12"). ...ctural Sheet Metal Roof Systems. The material must be located between the insulation and metal panels/ventilation material.
    4 KB (537 words) - 17:35, 17 March 2023
  • ;(2) [[ASM Roof Systems Standard#PART_7|'''Insulation''']]: Offset and stagger layers 300 mm (12"). ...ctural Sheet Metal Roof Systems. The material must be located between the insulation and metal panels/ventilation material (see [http://rpm.rcabc.org/index.php?
    4 KB (530 words) - 20:11, 28 June 2022
  • ...ctural Sheet Metal Roof Systems. The material must be located between the insulation and metal panels (see [http://rpm.rcabc.org/index.php?title=RoofStar_Guaran
    3 KB (430 words) - 16:23, 28 June 2022
  • ;(4) [[ASM Roof Systems Standard#PART_7|'''Insulation''']]: Tapered to support gutter membrane, which is tied into underlayment, ...ART_7| '''Upper insulation''']]: Tapered at lower edge to conform to lower insulation slope. All flat panels must be offset and stagger layers 300 mm (12").
    5 KB (611 words) - 18:17, 12 March 2024
  • ...oof system specifications. In addition, approved proprietary underlayment, insulation overlays and metal panel separation sheets must be installed and comply to (2) <b>Ice Dam Protection / Insulation Overlay: </b>For slopes 2:12 to 4:12 use RGC accepted self-adhered modified
    3 KB (421 words) - 22:51, 21 December 2015
  • ...Standard#PART_5|'''Gypsum Deck Overlay''']]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ...uarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual.
    3 KB (383 words) - 21:38, 27 June 2022
  • ;(5) [[Grade-level Waterproofing Standard#WPINSULATION | '''Insulation''']]: Optional: Extruded, Expanded Polystyrene, Type 4, CAN/ULC-S701-97, co
    4 KB (527 words) - 21:15, 7 September 2021
  • ;(6) [[Grade-level Waterproofing Standard#WPINSULATION | '''Insulation''']]: Optional: Extruded, Expanded Polystyrene, Type 4, CAN/ULC-S701-97, co ...]: Synthetic permeable fabric required over extruded, expanded polystyrene insulation overburdened with pavers, growing mediums, sand and gravel beds for unit ma
    4 KB (527 words) - 21:16, 7 September 2021
  • ...oofing Standard#WPDECK | '''Plaza Deck Assembly''']]: Extruded polystyrene insulation and filter mat (optional) over primary waterproofing membrane. Concrete pav
    5 KB (580 words) - 21:16, 7 September 2021
  • ;(3) [[Grade-level Waterproofing Standard#WPINSULATION | '''Insulation''']]: Extruded, Expanded Polystyrene, Type 4, CAN/ULC-S701-97, compressive ;(B) Supporting Curb: Height varies depending on the insulation thickness and type of waterproofing assembly.
    4 KB (596 words) - 21:17, 7 September 2021
  • ...ng Standard#WPINSULATION | '''Insulation''']]: Type 4 extruded polystyrene insulation ...paver pedestals designed to carry predicted live loads and accepted by the insulation manufacturer.
    3 KB (413 words) - 21:22, 7 September 2021
  • ;(2) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: Installed in staggered and offset layers (not illustrated), and secur ;(3) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]: Subject to the requirements of Part 8 in the Standard.
    3 KB (472 words) - 17:57, 27 October 2023
  • ;(2) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: Installed in staggered and offset layers (not illustrated), and secur ;(3) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]: Subject to the requirements of '''Part 8''' in the '''''RoofS
    3 KB (446 words) - 17:36, 27 October 2023
  • ...('''5''')('''4'''). In all other cases, a second drainage layer above the insulation is discretionary). Turn the drainage layer up at the perimeter to convey w ;(6) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: XPS insulation, ideally installed in multiple layers that are offset and staggered as illu
    5 KB (661 words) - 17:37, 27 October 2023
  • ;(7) '''Plaza Deck / Planter Interior Assembly''': Extruded polystyrene insulation and filter mat over primary roof membranes. Concrete pavers placed above pr
    4 KB (513 words) - 18:21, 27 October 2023
  • * Insulation to replace any wet materials discovered in cuts ...entrapped air or water, usually over decks with concrete fills or with wet insulation.</td>
    75 KB (11,617 words) - 21:00, 3 September 2021
  • ...roofing materials and components, such as single-ply membranes, flashings, insulation boards, etc. Before adhesives are applied, their compatibility with other :Applying hot asphalt to what will be the concealed side of a material (insulation sheet, felt, etc.) before turning it over and arranging it in place.
    76 KB (11,565 words) - 18:09, 26 January 2024
  • <u>RSI - Roofing / Siding / Insulation</u>. 7500 Old Oak Boulevard, Cleveland, OH 44130.
    4 KB (548 words) - 14:32, 18 August 2023
  • ===[[RoofStar Guarantee Standards for EPDM Membrane Systems#EPDMINSULATION | Insulation]] === :<big><big>Composite Board Insulation</big></big>
    5 KB (633 words) - 20:30, 26 July 2021