ASM Eave and Rake Edges (Snap-Lock Seams)

Jump to: navigation, search

ASM Eave and Rake Edges (Snap-Lock Seams)

Revision as of 20:33, 7 September 2021 by James Klassen (talk | contribs)



Division D - Construction Details


ASM 10.1.2 Eave and Rake Flashing (Snap Seam)

Notice to Reader
Images used in a Construction Detail are representative and not prescriptive. Nor are they necessarily drawn to scale. Rather, they are provided to visually convey the requirements of the Standard they represent. Unless otherwise required by the Standard, dimensions, the selection of materials and their application remains the responsibility of the Design Authority.

The full text of the referenced requirements in the Standard may be read by using the blue hyperlinks
ASM Details

8.1.4.4.1.jpg

1 WORK INCLUDED

(1) Ice and Water Protection
Accepted self-adhered modified bituminous membrane.
(2) Slip Sheet
Recommended over asphaltic underlays and / or as required by metal panel manufacturer.
(3) Metal Panel Clip
Installed to metal roof panel manufacturer's printed instructions.
(4) Architectural Metal Roof Panel
(5) Continuous Metal Cleat
(6) Metal Fascia Flashing
(7) Edge Metal Flashing (Continuous)
(8) Pre-formed Closures
(9) Exposed Fasteners
High-domed gasketed cladding type screws compatible with metal roof panel.
(10) Rake Edge Metal Flashing

2 RELATED WORK BY OTHERS

(A) Acceptable Deck
(B) Fascia Board


NOTE: See the Standard for additional requirements.


Back to ASM Roof System Details

Home

© RCABC 2024
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.