Difference between revisions of "Asphalt Shingle System Details"

Jump to: navigation, search

Difference between revisions of "Asphalt Shingle System Details"

 
(43 intermediate revisions by the same user not shown)
Line 1: Line 1:
The drawings contained within this section are intended to represent a variety of asphalt shingle applications while remaining generic with regards to manufacturers’ specific application specifications. They do not represent all possible manufacturer application roof system designs. Consult manufacturers’ specifications and RoofStar Guarantee Standards to develop a system acceptable to both the manufacturer and RGC.
+
{{Template:RPM Info}}
  
For further information about asphalt shingle roof designs and requirements, see '''[[Asphalt Shingles Roof Systems]]'''.
+
__NONUMBEREDHEADINGS__
 +
{{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}}
 +
__NOTOC__
  
<div style="width:300px; text-align: left;">
+
:<big><big>Division D - Construction Details</big></big>
:[[File:Shingle Thumb (Main Page).jpg|300 px]]
+
:<hr>
 +
:<big><big><big><big><big>Construction Details for Asphalt Shingle Roof Systems</big></big></big></big></big>
 +
 
 +
<div class="col-md-2">
 +
:[[File:Asphalt Shingles.JPG | link=http://rpm.rcabc.org/images/8/8a/Asphalt_Shingles.JPG |175 px]]
 
</div>
 
</div>
 +
 +
<div class="col-md-10">
 +
:The drawings linked on this page are intended to represent a variety of asphalt shingle roof system applications while remaining generic with regards to ''manufacturer's'' specific application specifications. They do not represent all possible ''manufacturer'' application roof system designs. Consult each ''manufacturer's'' specifications and the '''''RoofStar Guarantee Standards''''' to develop a system acceptable to both the manufacturer and the '''''RoofStar Guarantee Program'''''.
 +
 +
:For further information about Asphalt Shingle Roof System designs and requirements, see the '''[https://rpm.rcabc.org/index.php?title=Asphalt_Shingle_Systems_Standard Standard for Asphalt Shingle Roof Systems]'''.
 +
</div>
 +
 
<div class="col-md-12">
 
<div class="col-md-12">
<div style="width:40px; vertical-align: center; text-align: left;">
 
[[File:Pdf.png|40 px]]
 
 
</div>
 
</div>
'''NOTE''': 'PDF' shown after a file name below indicates a downloadable print sheet is available for Construction Details. Click on the detail link and look for the icon.
+
<div class="col-md-4">
 +
<hr>
 +
===Part 6 - Air and Vapour Controls===
 +
====='''Continuity and Support''' ([[Asphalt_Shingle_Systems_Standard#6.3.2.1._Continuity_and_Support | Article 6.3.2.1.]])=====
 +
<ol>
 +
<li>[[Asphalt Shingles - Air and Vapour Controls | Air and Vapour Controls]]
 +
</li></ol>
 +
 
 +
===Part 9 - Roof Field (Shingle Systems)===
 +
====='''Application (Common and Steep Slopes)''' ([[Asphalt_Shingle_Systems_Standard#9.3.2.4. General Requirements for Asphalt Shingle Application| Article 9.3.2.4.]])=====
 +
 
 +
<ol>
 +
<li>[[Asphalt Shingles - Application (Common and Steep Slopes)| Application (Common and Steep Slopes)]]
 +
</li></ol>
 +
 
 +
====='''Application (Low Slopes)''' ([[Asphalt_Shingle_Systems_Standard#9.3.2.5. Application on Slopes Less Than 1:3 | Article 9.3.2.4.]])=====
 +
 
 +
<ol>
 +
<li>[[Asphalt Shingles - Application (Low Slopes) | Application (Low Slopes)]]
 +
</li></ol>
 +
 
 +
====='''Changes in Slope''' ([[Asphalt_Shingle_Systems_Standard#9.3.2.7. Changes in Slope | Article 9.3.2.7.]])=====
 +
 
 +
<ol>
 +
<li>[[Asphalt Shingles - Changes in Slope (Inside Angle) | {{hilite | Changes in Slope (Inside Angle) || 2020-October-21 }}]]
 +
<li>[[Asphalt Shingles - Changes in Slope (Outside Angle) | {{hilite | Changes in Slope (Outside Angle) || 2020-October-21 }}]]
 +
</li></ol>
 +
 
 
</div>
 
</div>
<div class="col-md-6">
+
<div class="col-md-4">
 
<hr>
 
<hr>
:[[AS Details:E2.7.1 (Shingle Application - All Slopes)|E2.7.1 Shingle Application - All Slopes]]
+
 
:[[AS Details:E2.7.2 (Low Slope Shingle Application)|E2.7.2 Low Slope Shingle Application]]
+
===Part 10 - Perimeters and Valleys===
:[[AS Details:E2.7.3 (Open Valley)|E2.7.3 Open Valley]]
+
====='''Eave and Rake Edge Details''' ([[Asphalt_Shingle_Systems_Standard#10.3.4.2._Eaves_and_Rake_Edges | Article 10.3.4.2.]])=====
:[[AS Details:E2.7.4 (Closed Cut Valley)|E2.7.4 Closed Cut Valley]]
+
<ol>
:[[AS Details:E2.7.5 (Woven Valley)|E2.7.5 Woven Valley]]
+
<li>[[Asphalt Shingles - Eaves (All Slopes) | Eaves (All Slopes)]]
:[[AS Details:E2.7.6 (Upper Junction Detail - Asphalt Shingle at BUR)|E2.7.6 Upper Junction Detail - Asphalt Shingle at BUR]]
+
<li>[[Asphalt Shingles - Diverter Flashing | {{hilite | Diverter Flashing || 2020-October-21 }}]]
 +
</li></ol>
 +
 
 +
====='''Valleys''' ([[Asphalt_Shingle_Systems_Standard#10.3.5.2._General_Requirements_for_Valley_Metal_Flashing | Article 10.3.5.2.]])=====
 +
 
 +
<ol>
 +
<li>[[Asphalt Shingles - Open Valley | Open Valley]]
 +
<li>[[Asphalt Shingles - Closed (Cut) Valley| Closed (Cut) Valley]]
 +
<li>[[Asphalt Shingles - Woven Valley| Woven Valley]]
 +
</li></ol>
 +
 
 +
====='''Valley Intersections with Ridge''' ([[Asphalt_Shingle_Systems_Standard#10.3.5.9. Valley Intersection with Ridge | Article 10.3.5.9.]])=====
 +
 
 +
<ol>
 +
<li>[[Asphalt Shingles - Valley Intersection with Ridge | Valley Intersection with Ridge]]
 +
</li></ol>
 +
 
 +
====='''Intersections with Waterproofing Roof Systems''' ([[Asphalt_Shingle_Systems_Standard#10.3.7.2. Intersections with Waterproofing Roof Systems | Article 10.3.7.2.]])=====
 +
 
 +
<ol>
 +
<li>[[Asphalt Shingles - Intersection with Waterproofing Roof (Upper)| Intersection with Waterproofing Roof (Upper)]]
 +
<li>[[Asphalt Shingles - Intersection with Waterproofing Roof (Lower)| Intersection with Waterproofing Roof (Lower)]]
 +
</li></ol>
 +
 
 
</div>
 
</div>
<div class="col-md-6">
+
<div class="col-md-4">
 
<hr>
 
<hr>
:[[AS Details:E2.7.7 (Lower Junction Detail - Asphalt Shingle at BUR)|E2.7.7 Lower Junction Detail - Asphalt Shingle at BUR]]
+
 
:[[AS Details:E2.7.8 (Eave Detail - All Slopes)|E2.7.8 Eave Detail - All Slopes]]
+
===Part 11 - Drainage===
:[[AS Details:E2.7.9 (Chimney Flashing Detail)|E2.7.9 Chimney Flashing Detail]]
+
====='''Membrane Gutters''' ([[Asphalt_Shingle_Systems_Standard#11.3.3.8._Membrane_Gutters | Article 11.3.3.8.]])=====
:[[AS Details:E2.7.10 (Lead Vent - Typical)|E2.7.10 Lead Vent - Typical]]
+
 
:[[AS Details:E2.7.11 (Counter-Flashing - Diverter Flashing)|E2.7.11 Counter-flashing - Diverter Flashing]]
+
<ol>
:[[AS Details:E2.7.12 (Integral Flashing with Capillary Table)|E2.7.12 Integral Flashing with Capillary Table]]
+
<li>[[Asphalt Shingles - Membrane Gutter (Design Elements)| Membrane Gutter (Design Elements)]]
 +
</li></ol>
 +
 
 +
===Part 12 - Penetrations and Curbs===
 +
====='''Penetration Flashing''' ([[Asphalt_Shingle_Systems_Standard#12.3.2.1._General_Requirements_for_Flashing_Penetrations | Article 12.3.2.1.]])=====
 +
 
 +
<ol>
 +
<li>[[Asphalt Shingles - Cylindrical Penetration (Lead Flashing)| Cylindrical Penetration (Lead Flashing)]]
 +
<li>[[Asphalt Shingles - Cylindrical Penetration (Flashing, Storm Collar) | {{hilite | Cylindrical Penetration (Flashing, Storm Collar)|| 2022-February-5 }}]]
 +
</li></ol>
 +
 
 +
====='''Curbs''' ([[Asphalt_Shingle_Systems_Standard#12.3.2.4._Curbs_and_Sleepers | Article 12.3.2.4.]])=====
 +
 
 +
<ol>
 +
<li>[[Asphalt Shingles - Curb Flashing (Typical) | Curb Flashing (Typical)]]
 +
<li>[[Asphalt Shingles - Flashing a Masonry Chimney| Flashing a Masonry Chimney]]
 +
</li></ol>
 +
 
 +
===Part 13 - Linear Metal Flashing===
 +
:See the separate page, [[Linear_Metal_Flashing_Details | Details for Linear Metal Flashings]].
 +
 
 
</div>
 
</div>
 +
 
<div class="col-md-12">
 
<div class="col-md-12">
 +
<hr>
  
 +
[[Asphalt Shingle Systems Standard|<i class="fa fa-chevron-circle-left" ></i> ''Standard for Asphalt Shingle Roof Systems'']]
  
 
+
[[Main Page | <i class="fa fa-home fa"></i> Home]]
[[Asphalt Shingles|<i class="fa fa-chevron-circle-left" ></i> Back to ''Asphalt Shingle Roof Systems'']]
+
{{Template:RPM Page Footer with Copyright and Current Date}}
 
 
[[Construction Details|<i class="fa fa-chevron-circle-left" ></i> Back to ''Construction Details Section'']]
 
 
</div>
 
</div>

Latest revision as of 15:53, 30 June 2022



Division D - Construction Details

Construction Details for Asphalt Shingle Roof Systems
Asphalt Shingles.JPG
The drawings linked on this page are intended to represent a variety of asphalt shingle roof system applications while remaining generic with regards to manufacturer's specific application specifications. They do not represent all possible manufacturer application roof system designs. Consult each manufacturer's specifications and the RoofStar Guarantee Standards to develop a system acceptable to both the manufacturer and the RoofStar Guarantee Program.
For further information about Asphalt Shingle Roof System designs and requirements, see the Standard for Asphalt Shingle Roof Systems.

Part 6 - Air and Vapour Controls

Continuity and Support ( Article 6.3.2.1.)
  1. Air and Vapour Controls

Part 9 - Roof Field (Shingle Systems)

Application (Common and Steep Slopes) ( Article 9.3.2.4.)
  1. Application (Common and Steep Slopes)
Application (Low Slopes) ( Article 9.3.2.4.)
  1. Application (Low Slopes)
Changes in Slope ( Article 9.3.2.7.)
  1. Changes in Slope (Inside Angle)
  2. Changes in Slope (Outside Angle)

Standard for Asphalt Shingle Roof Systems

Home

© RCABC 2024
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.