=== WORK INCLUDED ===
 
=== WORK INCLUDED ===
;(1) [[Standard for Asphalt Shingle Systems#AShEAVE-UNDERLAYMENT|'''Eave Protection''']]: One ply of self-adhered modified bituminous underlayment material or other acceptable eaves protection.  Lap 50 mm (2") minimum on sides and 150 mm (6") minimum on ends.  Refer also to [[Standard for Asphalt Shingle Systems#LSEAVE|'''2.2.2 Eave Protection / Underlay''']].
+
;(1) [[Standard for Asphalt Shingle Systems|'''Eave Protection''']]: One ply of self-adhered modified bituminous underlayment material or other acceptable eaves protection.  Lap 75 mm (3") minimum on sides and 150 mm (6") minimum on ends.
 
;(2) [[Standard for Asphalt Shingle Systems#AShUNDERLAYMENT|'''Underlayment''']]: Minimum one ply of No. 15 non-perforated asphalt saturated felt or accepted eaves protection. Overlap 50 mm (2") minimum on side laps and 150 mm (6") minimum on end laps.
 
;(2) [[Standard for Asphalt Shingle Systems#AShUNDERLAYMENT|'''Underlayment''']]: Minimum one ply of No. 15 non-perforated asphalt saturated felt or accepted eaves protection. Overlap 50 mm (2") minimum on side laps and 150 mm (6") minimum on end laps.
;(3) '''Edge Metal Flashing''': Optional (cf. [[Standard for Asphalt Shingle Systems#ASLSEDGE|'''1.2.10 Wood Deck Overlay Sheathing (Non-Structural)''']] for specific requirements), installed to manufacturer's printed instructions.
+
;(3) [[Standard for Asphalt Shingle Systems#AShPERIM-GEN-APPLICATION|'''Edge Metal Flashing''']]: Required for all eave and rake edges.
;(4) [[Standard for Asphalt Shingle Systems#AShGEN-APPLICATION|'''Starter Course''']]: '''Standard Strip and interlocking shingles''' starter course consist of same type shingles as for roof, applied tabs facing up the slope. Laminated shingle starter courses consist of Manufacturer's proprietary starter shingles or same type shingle with the exposed (bottom) portion cut off below the seal strip. Apply to Manufacturer's printed application instructions.
+
;(4) [[Standard for Asphalt Shingle Systems#AShPART9GEN-APPLICATION|'''Starter Course''']]: '''Standard strip, laminated or architectural shingle''' starter course consists of proprietary starter shingles or (in the case of strip shingles) the same type shingles used in the field. Install according to requirements in Subsection '''9.3.1 General''', together with the Manufacturer's printed application instructions.
;(5) '''Standard Strip, Laminated or Interlocking Shingles''': Applied as recommended by manufacturer.
+
;(5) '''Standard Strip, Laminated or Architectural Shingles''': Applied as recommended by manufacturer.
;(6) [[Standard for Asphalt Shingle Systems#AShSECUREMENT|'''Nailing''']]: Note manufacturer's recommended nailing pattern. Placement varies with manufacturer.
+
;(6) [[Standard for Asphalt Shingle Systems#AShSECUREMENT|'''Nailing''']]: See the requirements in Section '''3.3 Application'''.
  
 
<hr>
 
<hr>

Revision as of 14:29, 8 June 2021

RoofStar Guarantee Standards are blue-linked
Asphalt Shingle Details

Applicable to slopes 1:3 (4" in 12") and greater. 7.1.2.1.1.jpg

1 WORK INCLUDED

(1) Eave Protection
One ply of self-adhered modified bituminous underlayment material or other acceptable eaves protection. Lap 75 mm (3") minimum on sides and 150 mm (6") minimum on ends.
(2) Underlayment
Minimum one ply of No. 15 non-perforated asphalt saturated felt or accepted eaves protection. Overlap 50 mm (2") minimum on side laps and 150 mm (6") minimum on end laps.
(3) Edge Metal Flashing
Required for all eave and rake edges.
(4) Starter Course
Standard strip, laminated or architectural shingle starter course consists of proprietary starter shingles or (in the case of strip shingles) the same type shingles used in the field. Install according to requirements in Subsection 9.3.1 General, together with the Manufacturer's printed application instructions.
(5) Standard Strip, Laminated or Architectural Shingles
Applied as recommended by manufacturer.
(6) Nailing
See the requirements in Section 3.3 Application.