Difference between revisions of "Asphalt Shingles - Application (Common and Steep Slopes)"

Jump to: navigation, search

Difference between revisions of "Asphalt Shingles - Application (Common and Steep Slopes)"

Line 1: Line 1:
 
{{Template:RPM Info}}
 
{{Template:RPM Info}}
 
+
<hr>
 
{| class="wikitable" | style="color: black; background-color: orange; width: 100%;text-align:center"
 
{| class="wikitable" | style="color: black; background-color: orange; width: 100%;text-align:center"
| colspan="2"  | <big>'''''RoofStar Guarantee Standards''''' are <span style="color:#6495ed">'''blue-linked'''</span></big>
+
| colspan="2"  | <big>'''''Notice to Reader'''''</big>
 +
|-
 +
| style="color: black; background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive.  Nor are they necessarily drawn to scale. Rather, they are provided to visually convey the requirements of the Standard they represent. Unless otherwise required by the Standard, dimensions, the selection of materials and their application remains the responsibility of the ''Design Authority''.<br><br>The full text of the referenced requirements in the [[Asphalt Shingle Systems Standard | '''Standard''']] may be read by using the <span style="color:#6495ed">'''blue hyperlinks'''</span>
 
|}
 
|}
 
<div class="panel panel-success">
 
<div class="panel panel-success">
Line 16: Line 18:
 
<div class="col-md-6">
 
<div class="col-md-6">
 
=== WORK INCLUDED ===
 
=== WORK INCLUDED ===
;(1) [[Standard for Asphalt Shingle Systems|'''Eave Protection''']]: One ply of self-adhered modified bituminous underlayment material or other acceptable eaves protection.  Lap 75 mm (3") minimum on sides and 150 mm (6") minimum on ends.
+
;(1) [[Asphalt Shingle Systems Standard|'''Eave Protection''']]: One ply of self-adhered modified bituminous underlayment material or other acceptable eaves protection.  Lap 75 mm (3") minimum on sides and 150 mm (6") minimum on ends.
;(2) [[Standard for Asphalt Shingle Systems#AShUNDERLAYMENT|'''Underlayment''']]: Minimum one ply of No. 15 non-perforated asphalt saturated felt or accepted eaves protection. Overlap 50 mm (2") minimum on side laps and 150 mm (6") minimum on end laps.
+
;(2) [[Asphalt Shingle Systems Standard#AShUNDERLAYMENT|'''Underlayment''']]: Minimum one ply of No. 15 non-perforated asphalt saturated felt or accepted eaves protection. Overlap 50 mm (2") minimum on side laps and 150 mm (6") minimum on end laps.
;(3) [[Standard for Asphalt Shingle Systems#AShPERIM-GEN-APPLICATION|'''Edge Metal Flashing''']]: Required for all eave and rake edges.
+
;(3) [[Asphalt Shingle Systems Standard#AShPERIM-GEN-APPLICATION|'''Edge Metal Flashing''']]: Required for all eave and rake edges.
;(4) [[Standard for Asphalt Shingle Systems#AShPART9GEN-APPLICATION|'''Starter Course''']]: '''Standard strip, laminated or architectural shingle''' starter course consists of proprietary starter shingles or (in the case of strip shingles) the same type shingles used in the field.  Install according to requirements in Subsection '''9.3.1 General''', together with the Manufacturer's printed application instructions.
+
;(4) [[Asphalt Shingle Systems Standard#AShPART9GEN-APPLICATION|'''Starter Course''']]: '''Standard strip, laminated or architectural shingle''' starter course consists of proprietary starter shingles or (in the case of strip shingles) the same type shingles used in the field.  Install according to requirements in Subsection '''9.3.1 General''', together with the Manufacturer's printed application instructions.
 
;(5) '''Standard Strip, Laminated or Architectural Shingles''': Applied as recommended by manufacturer.
 
;(5) '''Standard Strip, Laminated or Architectural Shingles''': Applied as recommended by manufacturer.
;(6) [[Standard for Asphalt Shingle Systems#AShSECUREMENT|'''Nailing''']]:  See the requirements in Section '''3.3 Application'''.
+
;(6) [[Asphalt Shingle Systems Standard#AShSECUREMENT|'''Nailing''']]:  See the requirements in Section '''3.3 Application'''.
  
 
<hr>
 
<hr>
  
 
=== RELATED WORK BY OTHERS ===
 
=== RELATED WORK BY OTHERS ===
;(A) [[Standard for Asphalt Shingle Systems#AShDECKS|'''Acceptable Deck''']]
+
;(A) [[Asphalt Shingle Systems Standard#AShDECKS|'''Acceptable Deck''']]
 
</div><!-- COL-6-MD -->
 
</div><!-- COL-6-MD -->
 
</div><!-- PANEL BODY -->
 
</div><!-- PANEL BODY -->
 
</div><!-- PANEL -->
 
</div><!-- PANEL -->
  
'''NOTE''': Refer to '''''RoofStar Guarantee Standards''''' for additional requirements.
+
'''NOTE''': See the [[Asphalt Shingle Systems Standard | '''Standard''']] for additional requirements.
  
 
<hr>
 
<hr>
  
 +
[[Asphalt Shingle System Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''"SBS" Roof System Details'']]
  
[[Standard for Asphalt Shingle Systems|<i class="fa fa-chevron-circle-left fa" ></i> Standard for Asphalt Shingle Systems]]
+
[[Main Page | <i class="fa fa-home fa"></i> Home]]
 
 
[[Asphalt Shingle Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Asphalt Shingles Construction Details'']]
 
  
[[Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Construction Details'']]
+
{{Tempate:RPM Page Footer with Copyright and Current Date}}

Revision as of 15:42, 31 August 2021


Notice to Reader
Images used in a Construction Detail are representative and not prescriptive. Nor are they necessarily drawn to scale. Rather, they are provided to visually convey the requirements of the Standard they represent. Unless otherwise required by the Standard, dimensions, the selection of materials and their application remains the responsibility of the Design Authority.

The full text of the referenced requirements in the Standard may be read by using the blue hyperlinks
Asphalt Shingle Details

Applicable to slopes 1:3 (4" in 12") and greater. 7.1.2.1.1.jpg

1 WORK INCLUDED

(1) Eave Protection
One ply of self-adhered modified bituminous underlayment material or other acceptable eaves protection. Lap 75 mm (3") minimum on sides and 150 mm (6") minimum on ends.
(2) Underlayment
Minimum one ply of No. 15 non-perforated asphalt saturated felt or accepted eaves protection. Overlap 50 mm (2") minimum on side laps and 150 mm (6") minimum on end laps.
(3) Edge Metal Flashing
Required for all eave and rake edges.
(4) Starter Course
Standard strip, laminated or architectural shingle starter course consists of proprietary starter shingles or (in the case of strip shingles) the same type shingles used in the field. Install according to requirements in Subsection 9.3.1 General, together with the Manufacturer's printed application instructions.
(5) Standard Strip, Laminated or Architectural Shingles
Applied as recommended by manufacturer.
(6) Nailing
See the requirements in Section 3.3 Application.

2 RELATED WORK BY OTHERS

(A) Acceptable Deck

NOTE: See the Standard for additional requirements.


Back to "SBS" Roof System Details

Home

© RCABC 2024
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.