<hr>
 +
<big><big><big><big><big>Asphalt Shingles | Cylindrical Penetration (Flashing, Storm Collar) ([[Asphalt_Shingle_Systems_Standard#12.3.2.1. General Requirements for Flashing Penetrations | Article 12.3.2.1.]])</big></big></big></big></big>
 +
{{Template:Construction Details Header}}
 
<div class="panel panel-success">
 
<div class="panel panel-success">
 
<div class="panel-heading"><big>'''Asphalt Shingle Details'''</big></div>
 
<div class="panel-heading"><big>'''Asphalt Shingle Details'''</big></div>
Line 13: Line 19:
 
<div class="col-md-6">
 
<div class="col-md-6">
 
=== WORK INCLUDED ===
 
=== WORK INCLUDED ===
;(1) [[RoofStar Guarantee Standards for Asphalt Shingle Systems#AShEAVE-UNDERLAYMENT|'''Underlayment''']]: Self-adhering or mechanically fastened, depending upon the designed slope (see '''8.1.2 Design''').  Install “shingle-style” and overlap roll ends at least 150 mm (6”); side laps must be at least 75 mm (3”).
+
;(1) [[Asphalt Shingle Systems Standard#AShEAVE-UNDERLAYMENT|'''Underlayment''']]: Self-adhering or mechanically fastened, depending upon the designed slope (see '''8.1.2 Design''').  Install “shingle-style” and overlap roll ends at least 150 mm (6”); side laps must be at least 75 mm (3”).
;(2) [[RoofStar Guarantee Standards for Asphalt Shingle Systems#AShPENETRATIONFLASH|'''Penetration flashing''']]:Conforming to material standards in '''11.2 Materials'''.  Drawing shows cut-away, for illustrative purposes only.
+
;(2) [[Asphalt Shingle Systems Standard#AShPENETRATIONFLASH|'''Penetration flashing''']]:Conforming to material standards in '''11.2 Materials'''.  Drawing shows cut-away, for illustrative purposes only.
;(3) [[RoofStar Guarantee Standards for Asphalt Shingle Systems#AShPENETRATIONFLASHINSTALL|'''Horseshoe patch''']]: Self-adhered membrane cut to fit penetration flashing flange and extend beyond flange edges as shown in drawing and required in '''11.3.1 General'''.
+
;(3) [[Asphalt Shingle Systems Standard#AShPENETRATIONFLASHINSTALL|'''Horseshoe patch''']]: Self-adhered membrane cut to fit penetration flashing flange and extend beyond flange edges as shown in drawing and required in '''11.3.1 General'''.
;(4) [[RoofStar Guarantee Standards for Asphalt Shingle Systems#AShPENETRATIONFLASHINSTALL|'''Underlayment patch''']]: Overlaps the horseshoe patch and fits beneath the upper course of underlayment material.
+
;(4) [[Asphalt Shingle Systems Standard#AShPENETRATIONFLASHINSTALL|'''Underlayment patch''']]: Overlaps the horseshoe patch and fits beneath the upper course of underlayment material.
;(5) [[RoofStar Guarantee Standards for Asphalt Shingle Systems#AShPENETRATIONFLASHINSTALL|'''Drainage path (top of penetration flashing)''']]: Minimum 12 mm (1/2”).
+
;(5) [[Asphalt Shingle Systems Standard#AShPENETRATIONFLASHINSTALL|'''Drainage path (top of penetration flashing)''']]: Minimum 12 mm (1/2”).
;(6) [[RoofStar Guarantee Standards for Asphalt Shingle Systems#AShPENETRATIONFLASHINSTALL|'''Drainage path (side of penetration flashing)''']]:  Minimum 19 mm (3/4’).
+
;(6) [[Asphalt Shingle Systems Standard#AShPENETRATIONFLASHINSTALL|'''Drainage path (side of penetration flashing)''']]:  Minimum 19 mm (3/4’).
;(7) [[RoofStar Guarantee Standards for Asphalt Shingle Systems#AShFASTENERS|'''Exposed fasteners''']]: Cladding fasteners with gasketed washers.  See '''11.3.1 General''' and '''13.2.3 Fasteners'''.
+
;(7) [[Asphalt Shingle Systems Standard#AShFASTENERS|'''Exposed fasteners''']]: Cladding fasteners with gasketed washers.  See '''11.3.1 General''' and '''13.2.3 Fasteners'''.
;(8) [[RoofStar Guarantee Standards for Asphalt Shingle Systems#AShPENETRATIONFLASHINSTALL|'''Storm collar''']]: Required for pipe-type flashings (see '''11.3.3 Penetrations and Vents''').  Caulked with an untooled bead of an acceptable sealant.
+
;(8) [[Asphalt Shingle Systems Standard#AShPENETRATIONFLASHINSTALL|'''Storm collar''']]: Required for pipe-type flashings (see '''11.3.3 Penetrations and Vents''').  Caulked with an untooled bead of an acceptable sealant.
 
<hr>
 
<hr>
  
Line 29: Line 35:
 
</div><!-- PANEL -->
 
</div><!-- PANEL -->
  
'''NOTE''': Refer to '''''RoofStar Guarantee Standards''''' for additional requirements.
+
'''NOTE''': See the [[Asphalt Shingle Systems Standard | '''Standard''']] for additional requirements.
  
 
<hr>
 
<hr>
  
 +
[[Asphalt Shingle System Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Asphalt Shingle System Details'']]
  
[[RoofStar Guarantee Standards for Asphalt Shingle Systems|<i class="fa fa-chevron-circle-left fa" ></i> RoofStar Guarantee Standards for Asphalt Shingle Systems]]
+
[[Main Page | <i class="fa fa-home fa"></i> Home]]
 
 
[[Asphalt Shingle Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Asphalt Shingles Construction Details'']]
 
  
[[Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Construction Details'']]
+
{{Tempate:RPM Page Footer with Copyright and Current Date}}

Latest revision as of 14:44, 30 June 2022



Division D - Construction Details


Asphalt Shingles | Cylindrical Penetration (Flashing, Storm Collar) ( Article 12.3.2.1.)

Notice to Reader
Images used in a Construction Detail are representative and not prescriptive, and are not necessarily drawn to scale. They are intended to support the related Standard (Ref. Division A, Article 2.2.1.2.).

The reader may link to the related Article in the detail title, or link to the Standard as it relates to a specific element in the detail. All hyperlinks are displayed blue text.

Asphalt Shingle Details

ASh 11.3.1.jpg

1 WORK INCLUDED

(1) Underlayment
Self-adhering or mechanically fastened, depending upon the designed slope (see 8.1.2 Design). Install “shingle-style” and overlap roll ends at least 150 mm (6”); side laps must be at least 75 mm (3”).
(2) Penetration flashing
Conforming to material standards in 11.2 Materials. Drawing shows cut-away, for illustrative purposes only.
(3) Horseshoe patch
Self-adhered membrane cut to fit penetration flashing flange and extend beyond flange edges as shown in drawing and required in 11.3.1 General.
(4) Underlayment patch
Overlaps the horseshoe patch and fits beneath the upper course of underlayment material.
(5) Drainage path (top of penetration flashing)
Minimum 12 mm (1/2”).
(6) Drainage path (side of penetration flashing)
Minimum 19 mm (3/4’).
(7) Exposed fasteners
Cladding fasteners with gasketed washers. See 11.3.1 General and 13.2.3 Fasteners.
(8) Storm collar
Required for pipe-type flashings (see 11.3.3 Penetrations and Vents). Caulked with an untooled bead of an acceptable sealant.

2 RELATED WORK BY OTHERS

(A) Penetration
(B-vent shown)

NOTE: See the Standard for additional requirements.