Difference between revisions of "Asphalt Shingles - Intersection with Waterproofing Roof (Lower)"

Jump to: navigation, search

Difference between revisions of "Asphalt Shingles - Intersection with Waterproofing Roof (Lower)"

 
(17 intermediate revisions by the same user not shown)
Line 1: Line 1:
{| class="wikitable" | style="color: black; background-color: orange; width: 100%;text-align:center"
+
{{Template:RPM Info}}
| colspan="2| <big>'''''RoofStar Guarantee Standards''''' are <span style="color:#6495ed">'''blue-linked'''</span></big>
+
 
|}
+
{{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}}
 +
__NOTOC__
 +
 
 +
<big><big>Division D - Construction Details</big></big>
 +
<hr>
 +
<big><big><big><big><big>Asphalt Shingles | Intersection with Waterproofing Roof (Lower) ([[Asphalt_Shingle_Systems_Standard#10.3.7.2. Intersections with Waterproofing Roof Systems | Article 10.3.7.2.]])</big></big></big></big></big>
 +
{{Template:Construction Details Header}}
 
<div class="panel panel-success">
 
<div class="panel panel-success">
 
<div class="panel-heading"><big>'''Asphalt Shingle Details'''</big></div>
 
<div class="panel-heading"><big>'''Asphalt Shingle Details'''</big></div>
Line 7: Line 13:
 
<div class="col-md-6">
 
<div class="col-md-6">
 
<div style="text-align:center; vertical-align:center">
 
<div style="text-align:center; vertical-align:center">
[[File:7.1.5.5.jpg|class=img-responsive]]
+
 
 +
{| class="wikitable"; table style="background-color:white"; border="#A9A9A9;"
 +
|+ Click on any image to expand it
 +
|-
 +
| [[File:ASh Intersection with Waterproofing Roof (Lower) 1.jpg| link=https://rpm.rcabc.org/images/b/b9/ASh_Intersection_with_Waterproofing_Roof_%28Lower%29_1.jpg| class=img-responsive ]]
 +
|-
 +
| [[File:ASh Intersection with Waterproofing Roof (Lower) 2.jpg| link=https://rpm.rcabc.org/images/4/46/ASh_Intersection_with_Waterproofing_Roof_%28Lower%29_2.jpg | class=img-responsive ]]  
 +
|}
 
</div>
 
</div>
 
</div><!-- COL-MD-6 -->
 
</div><!-- COL-MD-6 -->
  
 
<div class="col-md-6">
 
<div class="col-md-6">
 +
=== WORK INCLUDED ===
 +
;(1) [[Asphalt Shingle Systems Standard#AShUNDERLAYMENT|'''Underlayment''']]: Required, and installed to overlap the Valley Protection Membrane and the Valley Metal Flashing.  Install ‘shingle-style’, following the requirements for side and end laps; use acceptable fasteners, or adhere (if a self-adhering membrane) in keeping with the manufacturer’s published requirements.
 +
;(2) '''Starter Shingles'''
 +
;(3) [[Asphalt Shingle Systems Standard#AShPART9GEN-APPLICATION|'''Field Shingles''']]: Fasteners used to secure shingles must be at least 300 mm (12") above the finished surface of the ''roof waterproofing system''.
 +
;(4) Waterproofing roof system: Secure membrane to ''water-shedding roof deck'' at least 300 mm (12") above the finished surface of the ''roof waterproofing'' (refer to the related Membrane Standards, Part '''9 FIELD MEMBRANE''' and Part '''10 PERIMETERS and WALLS''').
  
 +
<hr>
 +
 +
=== RELATED WORK BY OTHERS ===
 +
;(A) [[Asphalt Shingle Systems Standard#AShDECK|'''Acceptable Deck''']]
 
</div><!-- COL-6-MD -->
 
</div><!-- COL-6-MD -->
 
</div><!-- PANEL BODY -->
 
</div><!-- PANEL BODY -->
 
</div><!-- PANEL -->
 
</div><!-- PANEL -->
  
'''NOTE''': Refer to '''''RoofStar Guarantee Standards''''' for additional requirements.
+
'''NOTE''': See the [[Asphalt Shingle Systems Standard | '''Standard''']] for additional requirements.
 
 
  
 
<hr>
 
<hr>
  
 +
[[Asphalt Shingle System Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Asphalt Shingle System Details'']]
  
 +
[[Main Page | <i class="fa fa-home fa"></i> Home]]
  
[[RoofStar Guarantee Standards for Asphalt Shingles Roof Systems|<i class="fa fa-chevron-circle-left fa" ></i> RoofStar Guarantee Standards for Asphalt Shingles Roof Systems]]
+
{{Tempate:RPM Page Footer with Copyright and Current Date}}
 
 
[[Asphalt Shingles Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Asphalt Shingles Construction Details'']]
 
 
 
[[Section:G. Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Construction Details'']]
 

Latest revision as of 14:11, 5 October 2022



Division D - Construction Details


Asphalt Shingles | Intersection with Waterproofing Roof (Lower) ( Article 10.3.7.2.)

Notice to Reader
Images used in a Construction Detail are representative and not prescriptive, and are not necessarily drawn to scale. They are intended to support the related Standard (Ref. Division A, Article 2.2.1.2.).

The reader may link to the related Article in the detail title, or link to the Standard as it relates to a specific element in the detail. All hyperlinks are displayed blue text.

Asphalt Shingle Details
Click on any image to expand it
ASh Intersection with Waterproofing Roof (Lower) 1.jpg
ASh Intersection with Waterproofing Roof (Lower) 2.jpg

1 WORK INCLUDED

(1) Underlayment
Required, and installed to overlap the Valley Protection Membrane and the Valley Metal Flashing. Install ‘shingle-style’, following the requirements for side and end laps; use acceptable fasteners, or adhere (if a self-adhering membrane) in keeping with the manufacturer’s published requirements.
(2) Starter Shingles
(3) Field Shingles
Fasteners used to secure shingles must be at least 300 mm (12") above the finished surface of the roof waterproofing system.
(4) Waterproofing roof system
Secure membrane to water-shedding roof deck at least 300 mm (12") above the finished surface of the roof waterproofing (refer to the related Membrane Standards, Part 9 FIELD MEMBRANE and Part 10 PERIMETERS and WALLS).

2 RELATED WORK BY OTHERS

(A) Acceptable Deck

NOTE: See the Standard for additional requirements.