Asphalt Shingles - Intersection with Waterproofing Roof (Lower)

Jump to: navigation, search

Asphalt Shingles - Intersection with Waterproofing Roof (Lower)

Revision as of 15:55, 31 August 2021 by James Klassen (talk | contribs)


Notice to Reader
Images used in a Construction Detail are representative and not prescriptive. Nor are they necessarily drawn to scale. Rather, they are provided to visually convey the requirements of the Standard they represent. Unless otherwise required by the Standard, dimensions, the selection of materials and their application remains the responsibility of the Design Authority.

The full text of the referenced requirements in the Standard may be read by using the blue hyperlinks
Asphalt Shingle Details
Click on any image to expand it
link=http://rpm.rcabc.org/images/e/ef/ASh 10.7.2-1 CD.jpg
link=http://rpm.rcabc.org/images/e/ed/ASh 10.7.2-2 CD.jpg

1 WORK INCLUDED

(1) Underlayment
Required, and installed to overlap the Valley Protection Membrane and the Valley Metal Flashing. Install ‘shingle-style’, following the requirements for side and end laps; use acceptable fasteners, or adhere (if a self-adhering membrane) in keeping with the manufacturer’s published requirements.
(2) Shingles (field)
(3) Field Shingles
Fasteners used to secure shingles must be at least 300 mm (12") above the finished surface of the roof waterproofing system.
(4) Field Membrane
Secure membrane to water-shedding roof deck at least 300 mm (12") above the finished surface of the roof waterproofing (refer to the related Membrane Standards, Part 9 FIELD MEMBRANE and Part 10 PERIMETERS and WALLS).

2 RELATED WORK BY OTHERS

(A) Acceptable Deck

NOTE: See the Standard for additional requirements.