Materials:NLSM LiteN'Less III

Jump to: navigation, search

Materials:NLSM LiteN'Less III



Division C - Accepted Materials
Group - Vegetated Roof Systems


NLSM LiteN'Less III
by Next Level Stormwater Management

System/Material Acceptance and Product Details


The information published in the RCABC Roofing Practices Manual and offered below does NOT represent a complete set of the manufacturer’s data or specifications, nor is this system and its various materials recommended or endorsed by the Guarantor. The preparation of a detailed specification is the responsibility of the Design Authority.

Vegetated Roof System Manufacturer
Name linked to website here
Accepted for the RoofStar Guarantee Program
October 25, 2024
Accepted for application in
Vegetated Roof Systems
Acceptance Criteria
Refer to the RGC Standard for Vegetated Roofs
System Summary
The LiteN’Less™ III system is lightweight and soilless, with no “loose” growing medium, and utilizes three layers of water retention fleece while still offering solutions for roof retrofits (adapted from the manufacturer's literature. See the link at right to the manufacturer's online resources page for more information).
Extensive VR System (banner).JPG
Manufacturer Online Resource
LiteN'Less III System
System Type
Extensive
System Depth
45.0 mm (1-13/16") to 62.0 mm (2-7/16")
Growing Media Depth
20 mm (13/16")
Vegetation Profile
Moss-Sedum
Suitable climate zones
All BC zones except Zone 4, subject to manufacturer's approval
System Components*
In the usual order, from top to bottom; click on link for Technical Data Sheet (TDS)
Conventionally Insulated Roof Assembly by roofing Contractor

Guarantor's Notes
Systems labeled "Inverted" are designed for a protected membrane roof assembly, also known as an inverted roof assembly.
While Semi-intensive and Intensive vegetated roof systems are limited to only protected membrane roofs (See the Sentence 1.1.3.2.(5) in the "RGC Standard for Vegetated Roofs"), some vegetated roof system manufacturers offer their systems for conventionally insulated roofs. To request a written Variance to the published limitation, follow the requirements in Article 1.1.3.6..
*Conditions and Limitations
Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements. Consult with the vegetated roof system manufacturer for options and saturated system weight.
Also note that vegetation coverage under the RoofStar Vegetated Roof Guarantee applies only to extensive systems planted with mats or trays - see Part 3 of Division A for more about coverage.



Back to Accepted Materials

Home