SBS Equipment Sleeper

Jump to: navigation, search

SBS Equipment Sleeper

Revision as of 16:07, 19 July 2016 by James Klassen (talk | contribs) (Created page with "File:10.3.5.2.jpg === WORK INCLUDED === (1) <b>Gypsum Overlay Board: </b>If required by design authority. (2) <b>Vapour Retarder</b>: If required by design authority....")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

10.3.5.2.jpg

1 WORK INCLUDED

(1) Gypsum Overlay Board: If required by design authority.

(2) Vapour Retarder: If required by design authority.

(3) Insulation

(4) Insulation Overlay: As required. See RGC Guarantee Standard B4.1, B4.2 and C4.1

(5) Primary Membrane and Membrane Protection

(6) Membrane Flashing: Lap one ply from each side over top of sleeper (C) and mechanically fasten.

(7) Alternate Cap Flashing: May be used instead of lapping membrane flashing over sleeper.

(8) Metal Base Flashing: Mechanically fasten to top of wood blocking, standing seam at corners, optional on flexible membrane systems. Optional on flexible membrane systems. Required on assemblies using gravel ballast filter mats. See RGC Guarantee Standard A6.9

(9) Metal Cap Flashing: Flashings

(8) and (9) may be one piece.

2 RELATED WORK BY OTHERS

(A) Acceptable Deck

(B) Air / Vapour Seal

(C) Wood Blocking / Sleeper: Minimum 150 mm (6") thick, minimum 100 mm (4") above finished roof surface.

NOTE: Refer to RGC Guarantee Standards for additional requirements.





Back to SBS Application

Back to SBS Construction Details

Back to Construction Details