Difference between revisions of "SBS Fall Protection Anchor in Wall (Protected)"

Jump to: navigation, search

Difference between revisions of "SBS Fall Protection Anchor in Wall (Protected)"

 
(No difference)

Latest revision as of 18:34, 27 June 2022



Division D - Construction Details


SBS | Fall Protection Anchor in Wall (Protected Roof System) ( Article 12.3.2.1.)

Notice to Reader
Images used in a Construction Detail are representative and not prescriptive, and are not necessarily drawn to scale. They are intended to support the related Standard (Ref. Division A, Article 2.2.1.2.).

The reader may link to the related Article in the detail title, or link to the Standard as it relates to a specific element in the detail. All hyperlinks are displayed blue text.

SBS Details

10.3.7.3.jpg

1 WORK INCLUDED

(1) Inverted (Protected) Roof Assembly
(2) Counter-flashing
(3) Insulation - XPS
See available insulation products in Division C of this Manual.
(4) Primary Membrane

2 RELATED WORK BY OTHERS

(A) Acceptable Supporting Deck Structure
(B) Anchor
Anchor selection and attachment details are the responsibility of the Design Authority.
(C) Anchor Eye
(D) Anchor Placement For Roof Decks Accessible By General Public/Residential Occupants
Maximum 100 mm (4") above finished roof surface (design to prevent climbing) and not less than 3-1/2" above the finished roof surfacing.
(E) Plywood
15.9 mm (5/8") treated where required.

NOTE: See the Standard for additional requirements.


Back to "SBS" Roof System Details

Home

© RCABC 2024
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.