1 WORK INCLUDED

(1) Inverted Roof Assembly

(2) Metal Counter Flashing

(3) Insulation: Extruded Polystyrene

(4) Primary Membrane

2 RELATED WORK BY OTHERS

(A) Acceptable Deck

(B) Anchor to CSA Z91-M90: Poured concrete shown, see anchor manufacturer’s attachment for other wall types and attachment methods

(C) Anchor Eye to CSA Z91-M90

(D) Anchor Placement For Roof Decks Accessible By General Public/Residential Occupants: Maximum 100 mm (4") above finished roof surface (design to prevent climbing) and not less than 3-1/2" above the finished roof surfacing.

(E) Plywood: 15.9 mm (5/8") treated where required.


NOTE: Refer to RGC Guarantee Standards for additional requirements.