Difference between revisions of "SBS Roof System Details"

Jump to: navigation, search

Difference between revisions of "SBS Roof System Details"

(Part 11 - Drainage)
(Part 1 - General)
Line 25: Line 25:
 
====Part 1 - General====
 
====Part 1 - General====
 
:'''Permitted Roof Systems''' (Article 1.1.3.1.)
 
:'''Permitted Roof Systems''' (Article 1.1.3.1.)
:[[SBS 1.1.3.-1 Conventionally Insulated System (typical) | {{hilite | SBS 1.1.3.1.-1 Conventionally Insulated System (typical)|| 2021-February-7 }}]]
+
:[[SBS 1.1.3.-1 Conventionally Insulated System (typical) | {{hilite | Conventionally Insulated System (typical)|| 2021-February-7 }}]]
:[[SBS 1.1.3.-2 Conventionally Insulated System (alternate) | {{hilite | SBS 1.1.3.1.-2 Conventionally Insulated System (alternate)|| 2021-February-7 }}]]
+
:[[SBS 1.1.3.-2 Conventionally Insulated System (alternate) | {{hilite | Conventionally Insulated System (alternate)|| 2021-February-7 }}]]
:[[SBS 1.1.3.-3 Protected Membrane Roof (typical) | {{hilite | SBS 1.1.3.1.-3 Protected Membrane Roof (typical)|| 2021-February-7 }}]]
+
:[[SBS 1.1.3.-3 Protected Membrane Roof (typical) | {{hilite | Protected Membrane Roof (typical)|| 2021-February-7 }}]]
  
 
====Part 2 (Reserved)====
 
====Part 2 (Reserved)====

Revision as of 20:18, 10 June 2022



Division D - Construction Details

Construction Details for SBS-modified Bitumen Membrane Roof Systems
The drawings linked on this page are intended to represent a variety of SBS-modified Bitumen Membrane roof system applications while remaining generic with regards to manufacturers’ specific application specifications. They do not represent all possible manufacturer application roof system designs. Consult each manufacturers’ specifications and the RoofStar Guarantee Standards to develop a system acceptable to both the manufacturer and the RoofStar Guarantee Program.
For further information about SBS-modified Bitumen Membrane System designs and requirements, see the Standard for SBS-modified Bitumen Membrane Roof Systems.
SBS Systems page thumb.JPG

Pdf.png

NOTE: 'PDF' shown after a file name below indicates a downloadable print sheet is available for Construction Details. Click on the detail link and look for the icon.


Part 1 - General

Permitted Roof Systems (Article 1.1.3.1.)
Conventionally Insulated System (typical)
Conventionally Insulated System (alternate)
Protected Membrane Roof (typical)

Part 2 (Reserved)

Part 3 (Reserved)

Part 4 (Reserved)

Part 5 - Deck and Wall Overlays

Part 6 - Air and Vapour Controls

SBS 6.3.2.1.-1 Air and Vapour Controls (field)

Part 7 (Reserved)

Part 8 (Reserved)

Part 9 (Reserved)

Part 10 - Perimeters and Walls

General Application ( Article 10.3.2.3.)
Perimeter Membrane Termination (typical)
Stucco Wall (replacement roofing)
Double Surface Reglet
Parapets (Article 10.3.4.1.)
Parapet (typical)
Parapet (independent of roof structure)(typical)
Parapet, tall (typical)
Parapet (wall tie-in)
Low-profile Edges (Article 10.3.4.2.)
Metal Edge Termination
Canted Edge
Fire Separation Walls (Article 10.3.4.4.)
SBS 10.3.4.4.-1 Fire Separation Joint
SBS 10.3.4.4.-2 Fire Separation Wall
Doors, Windows, and Wall Openings (Article 10.3.4.5.)
Low Door Opening
Window Opening
Expansion Joints (Article 10.3.6.1.)
Expansion Joint (at wall)
Expansion Joint (in field)
Control Joints (Roof Dividers) (Article 10.3.6.2.)
Control Joint (typical)

Standard for SBS-modified Bitumen Membrane Roof Systems

Home

© RCABC 2024