Difference between revisions of "SBS Roof System Details"

Jump to: navigation, search

Difference between revisions of "SBS Roof System Details"

(Part 12 - Penetrations and Curbs)
(Part 14 - The Roof as a Platform)
Line 119: Line 119:
  
 
====Part 14 - The Roof as a Platform====
 
====Part 14 - The Roof as a Platform====
:[[SBS 14.3.3 Structures and Equipment (planter pre-curb) | SBS 14.3.2.7.-1 Planter Wall ("pre-curb")]]
+
 
 +
:'''Structures and Equipment''' (Article 14.3.2.7.)
 +
:[[SBS 14.3.3 Structures and Equipment (planter pre-curb) | Planter Wall ("pre-curb")]]
  
 
</div>
 
</div>

Revision as of 20:22, 10 June 2022



Division D - Construction Details

Construction Details for SBS-modified Bitumen Membrane Roof Systems
The drawings linked on this page are intended to represent a variety of SBS-modified Bitumen Membrane roof system applications while remaining generic with regards to manufacturers’ specific application specifications. They do not represent all possible manufacturer application roof system designs. Consult each manufacturers’ specifications and the RoofStar Guarantee Standards to develop a system acceptable to both the manufacturer and the RoofStar Guarantee Program.
For further information about SBS-modified Bitumen Membrane System designs and requirements, see the Standard for SBS-modified Bitumen Membrane Roof Systems.
SBS Systems page thumb.JPG

Pdf.png

NOTE: 'PDF' shown after a file name below indicates a downloadable print sheet is available for Construction Details. Click on the detail link and look for the icon.


Part 1 - General

Permitted Roof Systems (Article 1.1.3.1.)
Conventionally Insulated System (typical)
Conventionally Insulated System (alternate)
Protected Membrane Roof (typical)

Part 2 (Reserved)

Part 3 (Reserved)

Part 4 (Reserved)

Part 5 - Deck and Wall Overlays

Part 6 - Air and Vapour Controls

SBS 6.3.2.1.-1 Air and Vapour Controls (field)

Part 7 (Reserved)

Part 8 (Reserved)

Part 9 (Reserved)

Part 10 - Perimeters and Walls

General Application ( Article 10.3.2.3.)
Perimeter Membrane Termination (typical)
Stucco Wall (replacement roofing)
Double Surface Reglet
Parapets (Article 10.3.4.1.)
Parapet (typical)
Parapet (independent of roof structure)(typical)
Parapet, tall (typical)
Parapet (wall tie-in)
Low-profile Edges (Article 10.3.4.2.)
Metal Edge Termination
Canted Edge
Fire Separation Walls (Article 10.3.4.4.)
SBS 10.3.4.4.-1 Fire Separation Joint
SBS 10.3.4.4.-2 Fire Separation Wall
Doors, Windows, and Wall Openings (Article 10.3.4.5.)
Low Door Opening
Window Opening
Expansion Joints (Article 10.3.6.1.)
Expansion Joint (at wall)
Expansion Joint (in field)
Control Joints (Roof Dividers) (Article 10.3.6.2.)
Control Joint (typical)

Part 11 - Drainage

General Requirements for Cast-iron Roof Drains (Article 11.3.3.2.)
Cast Iron Drains
Flanged Insert-type Roof Drains (Article 11.3.3.6.)
Flanged Drains (typical)
Flanged Drains (clamping)
Scuppers and Overflows (Article 11.3.3.7.)
Open Wall Scupper
Through-wall Scupper

Part 12 - Penetrations and Curbs

General Requirements for Flashing Penetrations (Article 12.3.2.1.)
Plumbing Vent
Two-part Cable Flashing
Multiple Penetration Flashing
Roof Anchors (typical)
Roof Anchors (conventional system)
Roof Anchors (PMRA)
Curbs, Sleepers, and Equipment Pads (Article 12.3.2.4.)
Uninsulated Curb
Insulated Curb (Mechanical)
Equipment Sleeper
Railings, Ladders, and Other Attached Structures (Article 12.3.2.7.)
Railing
Sealant Pockets (Article 12.3.2.8.)
Sealant Pocket (typical)

Part 13 - Linear Metal Flashing

See the separate page, Construction Details for Linear Metal Flashings.

Part 14 - The Roof as a Platform

Structures and Equipment (Article 14.3.2.7.)
Planter Wall ("pre-curb")

Standard for SBS-modified Bitumen Membrane Roof Systems

Home

© RCABC 2024
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.