Search results

Jump to: navigation, search

Search results

Page title matches

  • 37 bytes (3 words) - 17:31, 20 June 2016
  • <big><big><big><big><big>Roofs: Insulation Joint Tape</big></big></big></big></big> <big><big>[[Insulation Joints and Overlay|Insulation Joint Tape]]</big></big>
    960 bytes (129 words) - 21:48, 7 September 2021
  • ...g Roof System (typically ASM) to separate the roof panels from the primary insulation, and to provide a flat, firm surface for the installation of panel clips (u For more information about the use of insulation overlays in a Water-shedding Roof System, consult the specific roof system
    1 KB (185 words) - 14:15, 27 July 2021
  • ===Heat-resistant Insulation=== {{Template:Materials - Insulation (Polyisocyanurate)}}
    2 KB (251 words) - 14:13, 27 July 2021
  • {{Template:Materials - Insulation (XPS)}}
    485 bytes (56 words) - 14:10, 27 July 2021
  • File:7.1 Insulation Layering.jpg
    (1,789 × 728 (183 KB)) - 16:32, 15 February 2019
  • File:7.3 Insulation Offset and Staggered.jpg
    (1,196 × 744 (105 KB)) - 16:54, 15 February 2019
  • File:8.1 Insulation and Overlays.jpg
    (1,187 × 789 (148 KB)) - 17:12, 15 February 2019
  • 5 KB (545 words) - 18:11, 16 June 2023
  • ...nsulation with a nominal density approximately 100% higher than PlastiSpan insulation (Type 1) at 32 kg / m<sup>3</sup> (2.0 lb / ft<sup>3</sup>).
    1 KB (148 words) - 15:53, 2 November 2016
  • ...taper across the 1.2-rn (48") width. A predetermined layout of the tapered insulation boards is provided by Plasti-Fab in order to include a 1:50 (1/4" in 12") o ...back slopes are available; custom computerized design of PlastiSpan sloped insulation boards layout is provided..
    2 KB (230 words) - 15:53, 2 November 2016
  • ...le Corporation manufactures a variety of polyisocyanurate insulations. The insulation panels are manufactured with flexible facers, trilaminate foil, glassmat, o :ENRGY 3 CGF identifies the most widely used insulation using HCFC 141.b in the family of products manufactured by Johns Manville C
    3 KB (408 words) - 21:32, 3 November 2016
  • ...mmary''': PlastiSpan insulation identifies the most widely used PlastiSpan insulation in the family with a nominal density of 16 kg / m3 (1.0 lb / ft3). It provi
    1 KB (154 words) - 15:52, 2 November 2016
  • ...insulation with a normal density approximately 50% higher than PlastiSpan insulation (Type 1) at 24 kg / m<sup>3</sup> (1.5 lb / ft<sup>3</sup>).
    1 KB (148 words) - 15:52, 2 November 2016
  • :#Only RoofStar-accepted insulation, specifically listed by membrane manufacturers in the RPM as acceptable for ...ns are used in a roof assembly, they must be covered with a heat-resistant insulation at least 50 mm (2") thick. || 2019-February-16 }}
    18 KB (2,588 words) - 17:28, 13 March 2018
  • RoofStar-accepted insulation overlay boards shall be installed over all plastic foam insulations (EPS, X ...gered 300 mm (12") from adjacent layers and rows. The uppermost layer of [insulation or] overlay board directly below membranes shall have joints that are offse
    8 KB (1,100 words) - 17:05, 22 August 2017
  • RoofStar-accepted insulation overlay boards shall be installed over all plastic foam insulations (EPS, X ...gered 300 mm (12") from adjacent layers and rows. The uppermost layer of [insulation or] overlay board directly below membranes shall have joints that are offse
    8 KB (1,108 words) - 22:22, 18 October 2017
  • <big><big><big><big><big>Roofs: Insulation Overlays</big></big></big></big></big><br> Insulation overlays are used to separate the roof membrane from the primary insulation, usually for one of two reasons:
    3 KB (334 words) - 18:08, 16 June 2023
  • Polyisocyanurate is a closed-cell rigid foam material. The insulation boards are manufactured with asphalt-saturated felt, glass fibre or acrylic Polyisocyanurate foamboard roof insulation is presently manufactured to two standards:
    3 KB (421 words) - 14:50, 4 May 2017
  • 43 bytes (5 words) - 20:57, 16 June 2016

Page text matches

  • ...tion of, a roof or waterproofing membrane assembly. This excludes thermal insulation but includes, and is not limited to, || 2018-January-25 }} ...oot intrusion barrier, and drainage layer. Tightly butt all protection and insulation boards, overlap all filter mat seams and seal all laps of roof intrusion ba
    21 KB (2,722 words) - 14:55, 25 September 2017
  • ...tion of, a roof or waterproofing membrane assembly. This excludes thermal insulation but includes, and is not limited to, || 2018-January-25 }} ...oot intrusion barrier, and drainage layer. Tightly butt all protection and insulation boards, overlap all filter mat seams and seal all laps of roof intrusion ba
    21 KB (2,856 words) - 22:57, 9 November 2018
  • Only RoofStar-accepted insulation materials, specifically listed by membrane manufacturers in this Manual as ...be installed under two (2) offset / staggered layers of RoofStar-accepted insulation overlay boards.
    14 KB (2,160 words) - 15:21, 29 September 2016
  • ...ched) roofing membranes that are adhered directly to concrete decks unless insulation is installed directly above or over the membrane. ...tened insulation, the gypsum board must be fastened independently from the insulation. The minimum number of fasteners(screws or screws and plate) is four (4) pe
    5 KB (815 words) - 16:33, 29 September 2016
  • ...ight, and free of "humps" or depressions. These can counteract any sloped insulation systems installed by the roofing contractor and cause ponding. On new cons ...vel in the roof deck are less than the percentage of slope provided by the insulation.</span> <span class="recommended">A minimum slope of 1:50 (1/4" in 12") is
    20 KB (3,072 words) - 15:18, 15 January 2019
  • ...polystyrene with square edges, suitable for heavy loads. '''Sopra-XPS''' insulation is used in Protected Membrane Roof Assemblies and on plaza decks.
    1 KB (152 words) - 22:29, 31 January 2019
  • ...polystyrene with square edges, suitable for heavy loads. '''Sopra-XPS''' insulation is used in Protected Membrane Roof Assemblies and on plaza decks.
    1 KB (155 words) - 22:31, 31 January 2019
  • *Insulation (board or panel; tapered) *Insulation overlay board
    22 KB (3,050 words) - 16:20, 12 December 2023
  • * Use a protective base sheet on all wood decks and over ignitable insulation, can strips or other flammable surfaces. ...all ignitable insulation surfaces, edges and over all joints between rigid insulation boards. The base ply provides a protective covering for underlying ignitab
    14 KB (2,333 words) - 16:39, 9 February 2022
  • .../index.php?title=Standard_for_SBS-Modified_Bitumen_Membrane_Systems#PART_7 Insulation]=== :<big><big>Composite Board Insulation</big></big>
    6 KB (742 words) - 20:36, 27 July 2021
  • |+ EPS Insulation<br><small>Click on a manufacturer's name to see the full list of their prod ...| Plasti-Fab]]''' || [[Materials:Plastispan Insulation (Type 1)|Plastispan Insulation (Type 1)]] || style="text-align:center;"| ‒ || style="text-align:center;"
    7 KB (630 words) - 17:46, 24 June 2022
  • ====Insulation====
    2 KB (242 words) - 20:44, 8 June 2023
  • | [[#PART_7 | Part 7 - Insulation]] | [[#PART_8 | Part 8 - Insulation Overlays]]
    416 KB (56,532 words) - 22:23, 5 April 2024
  • | [[#PART_7 | Part 7 - Insulation]] | [[#PART_8 | Part 8 - Insulation Overlays]]
    424 KB (57,418 words) - 22:20, 5 April 2024
  • | [[#PART_7 | Part 7 - Insulation]] | [[#PART_8 | Part 8 - Insulation Overlays]]
    421 KB (57,062 words) - 22:20, 5 April 2024
  • | [[#PART_7 | Part 7 - Insulation]] | [[#PART_8 | Part 8 - Insulation Overlays]]
    296 KB (41,811 words) - 22:23, 5 April 2024
  • ...="1" rowspan="2" style="vertical-align:center;text-align:center;" | <small>Insulation<br>Overlay </small> ...="1" rowspan="2" style="vertical-align:center;text-align:center;" | <small>Insulation </small>
    5 KB (558 words) - 14:26, 7 April 2020
  • ...n flat or low-slope roofing. It can be installed over word decks or rigid insulation as an overlay board.</td>
    2 KB (285 words) - 20:47, 26 August 2021
  • <big><big>'''Secondary Materials: Insulation & Overlays'''</big></big> ...s - Insulation (Waterproofing Systems) | <i class="fa fa-caret-right"></i> Insulation]]</big>
    13 KB (1,636 words) - 17:02, 5 January 2024
  • ...ight, and free of "humps" or depressions. These can counteract any sloped insulation systems installed by the roofing contractor and cause ponding. On new cons ...vel in the roof deck are less than the percentage of slope provided by the insulation. A minimum slope of 1:50 (1/4" in 12") is strongly recommended. The except
    20 KB (2,969 words) - 16:06, 9 September 2021

View (previous 20 | next 20) (20 | 50 | 100 | 250 | 500)