Search results

Jump to: navigation, search

Search results

  • Refer to the '''Insulation''' or '''Membrane''' Manufacturer's specifications.
    227 bytes (26 words) - 13:51, 27 July 2021
  • ...terproofing membranes, testing shall be conducted prior to installation of insulation and overburdens and be performed to ASTM D5957 - 98.
    2 KB (249 words) - 22:45, 9 November 2016
  • <big><big><big><big><big>Roofs: Insulation</big></big></big></big></big> ===Heat-resistant Insulation===
    3 KB (377 words) - 21:49, 7 September 2021
  • <big><big><big><big><big>Insulation Joints and Overlays</big></big></big></big></big> Insulation overlays are used to separate the roof membrane from the primary insulation, usually for one of two reasons:
    4 KB (532 words) - 15:44, 9 September 2021
  • ;(6) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: See available insulation products in the [[Division C| Accepted Materials]] Division of this ''Manua
    3 KB (360 words) - 18:16, 27 October 2023
  • ;(3) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: See available insulation products in Division C of this ''Manual''.
    2 KB (262 words) - 18:33, 27 June 2022
  • ...[[SBS Roof Systems Standard#PART_7|'''Insulation - XPS''']]: See available insulation products in Division C of this ''Manual''.
    2 KB (284 words) - 18:34, 27 June 2022
  • ...ed. Installed according to ''RoofStar Guarantee Standards''. See available insulation products in the [[Division C | Division C]] of this Manual.
    3 KB (429 words) - 21:34, 27 June 2022
  • ...Standard#PART_5|'''Gypsum Deck Overlay''']]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ...ed. Installed according to ''RoofStar Guarantee Standards''. See available insulation products in the [[Division C | Division C]] of this Manual.
    3 KB (367 words) - 21:52, 27 June 2022
  • ...s#EPDMSUBSTRATES|'''Gypsum Deck Overlay''']]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ...uarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual.
    3 KB (351 words) - 16:48, 23 October 2017
  • ...s#EPDMSUBSTRATES|'''Gypsum Deck Overlay''']]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ...uarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual.
    3 KB (347 words) - 16:48, 23 October 2017
  • ...s#EPDMSUBSTRATES|'''Gypsum Deck Overlay''']]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ...uarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual.
    3 KB (332 words) - 16:49, 23 October 2017
  • ...s#EPDMSUBSTRATES|'''Gypsum Deck Overlay''']]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ...uarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual.
    3 KB (334 words) - 18:30, 23 October 2017
  • <big><big><big><big><big>Roofs: Insulation Joint Tape</big></big></big></big></big> <big><big>[[Insulation Joints and Overlay|Insulation Joint Tape]]</big></big>
    960 bytes (129 words) - 21:48, 7 September 2021
  • ...materials due to thermal and moisture variations. Traditionally, the roof insulation and roofing are secured to the roof deck by means of mechanical fastening, '''''RoofStar Guarantee Standards''''' requires mechanical fastening of the insulation wherever practical. Over concrete and other non-nailable decks, or where me
    7 KB (999 words) - 15:42, 9 September 2021
  • ...tables specified minimum thermal resistance values, depending on where the insulation was installed, but these requirements were not integrated with the design a
    21 KB (3,118 words) - 16:32, 16 March 2023
  • ...Standard#PART_7|'''Insulation''']]: Mechanically fastened. See available insulation products in the [[Division C| Accepted Materials]] Division of this ''Manua ;(3) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]: Where required.
    3 KB (440 words) - 18:14, 27 October 2023
  • ;(2) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: See available insulation products in the [[Division C| Accepted Materials]] Division of this ''Manua ;(3) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]: Where required.
    3 KB (420 words) - 18:15, 27 October 2023
  • ...existing coal tar pitch roofs. In these cases a separation layer, such as insulation board, is often used to prevent the asphalt system from contacting any trac | Insulation || +204°C (+400°F) to +149°C (+300°F) || 16 Seconds
    15 KB (2,293 words) - 15:33, 9 September 2021
  • ...re the insulation is above the membrane, the gravel is used to protect the insulation from ultraviolet rays, wind uplift, and flotation. For ballast and securem
    8 KB (1,280 words) - 16:25, 9 September 2021
  • ...#8220;conventional&#8221; roof assembly the roof membrane is on top of the insulation where it is subject to many life-shortening elements, and it must function ...roduce a problem with vapour trapped within the assembly. This can lead to insulation and roof membrane deterioration and, eventually, roof failure.
    11 KB (1,624 words) - 16:21, 9 September 2021
  • ...h living space condenses in the attic, producing moisture on wood framing, insulation and roofing. || [[File:Roofventcold.gif]] || Proper ventilation allows mois ...all be designed to prevent the entry of rain, snow and insects. || Ceiling insulation shall not be installed in a manner that will restrict free flow of air thou
    6 KB (911 words) - 15:33, 9 September 2021
  • ...uarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual. ...yed (3A: 2- part low rising insulation adhesive, specifically used to bond insulation and cover boards)
    4 KB (462 words) - 17:01, 23 October 2017
  • ...ts. Installed according to ''RoofStar Guarantee Standards''. See available insulation products in the [[Division C | Division C]] of this Manual.
    2 KB (281 words) - 21:53, 27 June 2022
  • ...ed. Installed according to ''RoofStar Guarantee Standards''. See available insulation products in the [[Division C | Division C]] of this Manual.
    3 KB (422 words) - 21:33, 27 June 2022
  • ...es#TPOSUBSTRATES|'''Gypsum Deck Overlay''']]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ...uarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual.
    3 KB (382 words) - 17:02, 23 October 2017
  • ...es#TPOSUBSTRATES|'''Gypsum Deck Overlay''']]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ...uarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual.
    3 KB (360 words) - 17:01, 23 October 2017
  • ...es#TPOSUBSTRATES|'''Gypsum Deck Overlay''']]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ...uarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual.
    3 KB (374 words) - 17:02, 23 October 2017
  • ...es#TPOSUBSTRATES|'''Gypsum Deck Overlay''']]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ...uarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual.
    3 KB (373 words) - 17:02, 23 October 2017
  • ...lso Accepted Roof Deck Insulation products by clicking on this [[Roof Deck Insulation|link]]. :{{Template:Insulation (Polyiso)}}
    146 bytes (19 words) - 17:16, 17 June 2016
  • ...g Roof System (typically ASM) to separate the roof panels from the primary insulation, and to provide a flat, firm surface for the installation of panel clips (u For more information about the use of insulation overlays in a Water-shedding Roof System, consult the specific roof system
    1 KB (185 words) - 14:15, 27 July 2021
  • ===Heat-resistant Insulation=== {{Template:Materials - Insulation (Polyisocyanurate)}}
    2 KB (251 words) - 14:13, 27 July 2021
  • {{Template:Materials - Insulation (XPS)}}
    485 bytes (56 words) - 14:10, 27 July 2021
  • ...oof Systems Standard#PART_5|'''Supporting Deck Overlay''']]: Required when insulation is too thin to span flutes of steel decking or when required as thermal bar ...Standard#PART_7|'''Insulation''']]: Mechanically fastened. See available insulation products in the[[Division C| Accepted Materials]] Division of this ''Manual
    4 KB (607 words) - 18:19, 27 October 2023
  • ;(3) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: Installed in staggered and offset layers, and secured in accordance w ;(4) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]: Subject to the requirements of '''Part 8''' in the '''''RoofS
    4 KB (630 words) - 18:16, 27 October 2023
  • ...oof Systems Standard#PART_5|'''Supporting Deck Overlay''']]: Required when insulation is too thin to span flutes of steel decking or when required as thermal bar ...Standard#PART_7|'''Insulation''']]: Mechanically fastened. See available insulation products in the [[Division C| Accepted Materials]] Division of this ''Manua
    3 KB (420 words) - 18:14, 27 October 2023
  • ;(3) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: Installed in staggered and offset layers (not illustrated), and secur ;(4) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]: Subject to the requirements of '''Part 8''' in the '''''RoofS
    3 KB (474 words) - 18:18, 27 October 2023
  • ;(2) '''Insulation Overlay Protection''': Recommended. ;(5) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMINS |'''Insulation''']]: Installed between &#8216;Z&#8217; bars or wood battens on 600 mm (24
    2 KB (291 words) - 16:27, 26 April 2019
  • ;(3) [[ASM Roof Systems Standard#PART_7|'''Insulation''']]: Installed with offset side and end joints. ...ctural Sheet Metal Roof Systems. The material must be located between the insulation and metal panels/ventilation material (see [http://rpm.rcabc.org/index.php?
    4 KB (540 words) - 17:25, 28 June 2022
  • ;(2) [[ASM Roof Systems Standard#PART_7|'''Insulation''']]: Offset and stagger layers 300 mm (12"). ...ctural Sheet Metal Roof Systems. The material must be located between the insulation and metal panels/ventilation material (see [http://rpm.rcabc.org/index.php?
    3 KB (432 words) - 19:00, 28 June 2022
  • ;(3) [[ASM Roof Systems Standard#PART_7|'''Insulation''']]: Offset and stagger layers 300 mm (12"). ...ctural Sheet Metal Roof Systems. The material must be located between the insulation and metal panels/ventilation material.
    4 KB (537 words) - 17:35, 17 March 2023
  • ;(2) [[ASM Roof Systems Standard#PART_7|'''Insulation''']]: Offset and stagger layers 300 mm (12"). ...ctural Sheet Metal Roof Systems. The material must be located between the insulation and metal panels/ventilation material (see [http://rpm.rcabc.org/index.php?
    4 KB (530 words) - 20:11, 28 June 2022
  • ...ctural Sheet Metal Roof Systems. The material must be located between the insulation and metal panels (see [http://rpm.rcabc.org/index.php?title=RoofStar_Guaran
    3 KB (430 words) - 16:23, 28 June 2022
  • ;(4) [[ASM Roof Systems Standard#PART_7|'''Insulation''']]: Tapered to support gutter membrane, which is tied into underlayment, ...ART_7| '''Upper insulation''']]: Tapered at lower edge to conform to lower insulation slope. All flat panels must be offset and stagger layers 300 mm (12").
    5 KB (611 words) - 18:17, 12 March 2024
  • ...oof system specifications. In addition, approved proprietary underlayment, insulation overlays and metal panel separation sheets must be installed and comply to (2) <b>Ice Dam Protection / Insulation Overlay: </b>For slopes 2:12 to 4:12 use RGC accepted self-adhered modified
    3 KB (421 words) - 22:51, 21 December 2015
  • ...Standard#PART_5|'''Gypsum Deck Overlay''']]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ...uarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual.
    3 KB (383 words) - 21:38, 27 June 2022
  • ;(5) [[Grade-level Waterproofing Standard#WPINSULATION | '''Insulation''']]: Optional: Extruded, Expanded Polystyrene, Type 4, CAN/ULC-S701-97, co
    4 KB (527 words) - 21:15, 7 September 2021
  • ;(6) [[Grade-level Waterproofing Standard#WPINSULATION | '''Insulation''']]: Optional: Extruded, Expanded Polystyrene, Type 4, CAN/ULC-S701-97, co ...]: Synthetic permeable fabric required over extruded, expanded polystyrene insulation overburdened with pavers, growing mediums, sand and gravel beds for unit ma
    4 KB (527 words) - 21:16, 7 September 2021
  • ...oofing Standard#WPDECK | '''Plaza Deck Assembly''']]: Extruded polystyrene insulation and filter mat (optional) over primary waterproofing membrane. Concrete pav
    5 KB (580 words) - 21:16, 7 September 2021
  • ;(3) [[Grade-level Waterproofing Standard#WPINSULATION | '''Insulation''']]: Extruded, Expanded Polystyrene, Type 4, CAN/ULC-S701-97, compressive ;(B) Supporting Curb: Height varies depending on the insulation thickness and type of waterproofing assembly.
    4 KB (596 words) - 21:17, 7 September 2021

View (previous 50 | next 50) (20 | 50 | 100 | 250 | 500)