Search results

Jump to: navigation, search

Search results

  • ...roofing felts. While offering the higher performance and versatility of a flexible membrane, these products also offer the practical advantages of bituminous Simply stated, flexible polybutadiene “chains” interconnect with the glass-like polysty
    22 KB (3,281 words) - 21:46, 17 July 2017
  • <big>Waterproofing Roof Systems: Thermosplastic Membranes</big><br> ...n of requirements previously published in the Roofing Practices Manual for Flexible Membrane Roofing Systems. It is comprised of fourteen (14) Parts that cont
    416 KB (56,532 words) - 22:23, 5 April 2024
  • <big>Waterproofing Roof Systems: Thermoset Membranes</big><br> ...n of requirements previously published in the Roofing Practices Manual for Flexible Membrane Roofing Systems. It is comprised of fourteen (14) Parts that cont
    424 KB (57,418 words) - 22:20, 5 April 2024
  • <big>Waterproofing Roof Systems: Thermosplastic Membranes</big><br> ...n of requirements previously published in the Roofing Practices Manual for Flexible Membrane Roofing Systems. It is comprised of fourteen (14) Parts that cont
    421 KB (57,062 words) - 22:20, 5 April 2024
  • <big>Waterproofing Roof Systems: Liquid Membranes</big><br> ...PM and Standards"]]. When the requirements in this Standard conflict with other resources found either in this Manual or in ''manufacturer's'' published in
    296 KB (41,811 words) - 22:23, 5 April 2024
  • ...he weight of live and dead loads to supporting members. Live loads include construction equipment and workers, rain, snow, and ice. Dead loads include the deck its ...ion systems installed by the roofing contractor and cause ponding. On new construction projects, this is usually provided by the general contractor with review by
    20 KB (2,969 words) - 16:06, 9 September 2021
  • <div class="panel-heading"><big>'''EPDM Details'''</big></div> ...n, standing seam at corners. Full width base flashing optional on flexible membranes. Partial skirt flashing minimum 75 mm (3") required on mechanical curbs tha
    3 KB (347 words) - 16:48, 23 October 2017
  • ...increased popularity of flexible membrane roofing systems. As building and construction technology become more sophisticated, the demands on the roofing membrane b ...membrane systems have the benefit of offering the physical properties of a flexible membrane while retaining the practical advantages of bituminous materials.
    23 KB (3,307 words) - 15:57, 9 September 2021
  • <div class="panel-heading"><big>'''TPO/PVC Details'''</big></div> ...n, standing seam at corners. Full width base flashing optional on flexible membranes. Partial skirt flashing minimum 75 mm (3") required on mechanical curbs tha
    3 KB (382 words) - 17:02, 23 October 2017
  • <big><big>Division D - Construction Details</big></big> {{Template:Construction Details Header}}
    4 KB (607 words) - 18:19, 27 October 2023
  • ...all isolated problems caused through abuse, stress concentration, error or other factors result in shortened lifespan. These small problems, if undetected, * As-built drawings of construction details directly related to the roofing system, such as flashings, deck, etc.
    75 KB (11,617 words) - 21:00, 3 September 2021
  • ...e use of contact cements, such as air-cured phenolic-neoprene mixtures, or other similar adhesives. See <b>ADHESION, ADHESIVE, BOND</b>. ...ation boards, etc. Before adhesives are applied, their compatibility with other roofing materials and components should be ensured through consultation wit
    76 KB (11,565 words) - 18:09, 26 January 2024
  • <big><big>Division D - Construction Details</big></big> {{Template:Construction Details Header}}
    3 KB (377 words) - 18:21, 27 October 2023
  • :[[Other Flexible Membranes - Introduction|<big>Introduction</big>]] :[[Other Flexible Membranes - Definition and Terms|<big>Definition and Terms</big>]]
    817 bytes (103 words) - 19:02, 23 October 2017
  • ...is the official version of the Roofing Practices Manual and supersedes all other printed versions which may be in circulation. ...The RPM meets or exceeds the current national and provincial standards for construction and wind uplift design resistance. It also includes
    7 KB (990 words) - 20:54, 2 August 2016
  • ...tandards for Waterproofing#WPPROTECTED|'''Protected and Modified Protected Membranes''']] <span class="reference">part of these Guarantee Standards, or to</span ...liance with National Building Code of Canada provisions for the design and construction of buildings their structural members made of plain, reinforced and pre-str
    117 KB (13,071 words) - 18:36, 5 April 2024
  • <i>Product Group:</i> <b>BUILT-UP ROOFING SYSTEMS EXPOSED MEMBRANES, INSULATED </b> ...mat used in GAF’s membranes provides excellent tensile strength. The GAF membranes are fully adhered with hot asphalt to prepared surfaces.
    25 KB (3,685 words) - 16:52, 4 November 2016
  • For application guidelines pertaining to Garland SBS membranes, see the [[Garland SBS Membrane Installation Guidelines|'''Garland SBS Memb ### Three-ply roof membranes: the first two plies consists of a type IV or Type VI glass felt; applied w
    22 KB (3,005 words) - 17:17, 4 November 2016
  • Distributor: <b>STEELS INDUSTRIAL PRODUCTS, PRO-LINE CONSTRUCTION MATERIALS</b> ...ponent of the roofing system is the Firestone RubberGard Membrane, a tough flexible EPDM (Ethylene Propylene Diene Terpolymer) based sheet, which is fully vulc
    46 KB (7,081 words) - 22:47, 7 November 2016
  • ...ed to provide premium performance at a very cost-effective price. Strong, flexible, durable EverGuard&#174; TPO membrane is suitable for use in fully adhered, :.2 Range of application: new construction and reroofing.
    12 KB (1,686 words) - 17:07, 8 November 2016