(WORK BY OTHERS)
Line 22: Line 22:
 
(4) [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPWEARING '''Pedestal''']: Proprietary (purpose-made) pedestals, with integral spacer ribs for uniform spacing between pavers that provide a minimum 12.5 mm (1/2") of vertical separation layer for airflow and levelling. Alternative: drainage boards with sand and gravel beds for unit masonry designed to provide permeable layer and levelling.
 
(4) [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPWEARING '''Pedestal''']: Proprietary (purpose-made) pedestals, with integral spacer ribs for uniform spacing between pavers that provide a minimum 12.5 mm (1/2") of vertical separation layer for airflow and levelling. Alternative: drainage boards with sand and gravel beds for unit masonry designed to provide permeable layer and levelling.
  
(7) [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPWEARING '''Pavers''']: Designed to support predicted live loads, maximum size 200mm (24") by 200mm (24").
+
(7) [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPWEARING '''Pavers''']: Designed to support predicted live loads, maximum size 600mm (24") by 600mm (24").
  
 
=== WORK BY OTHERS ===
 
=== WORK BY OTHERS ===

Revision as of 16:36, 16 August 2017

RoofStar Guarantee Standards are blue-linked
Waterproofing Details for Plazas, Promenades and Terraces

9.6.1.jpg

1 WORK INCLUDED

(1) Primary Waterproofing Membrane: Fully adhered to acceptable substrates (concrete slab shown), installed as per the RoofStar Guarantee Standards for Waterproofing Plazas, Promenades & Terraces and Membrane Manufacturer's installation specifications.

(2) Membrane Primer or Adhesive: Proprietary primer or adhesive, application method and quantities for substrate type as directed by membrane manufacturers published application specifications.

(3) Protection Board/Mat: Proprietary membrane protection board or drainage board approved by membrane manufacture, compatible with waterproofing membrane system, and compliant with the RoofStar Guarantee Standards for Waterproofing Plazas, Promenades & Terraces

(4) Pedestal: Proprietary (purpose-made) pedestals, with integral spacer ribs for uniform spacing between pavers that provide a minimum 12.5 mm (1/2") of vertical separation layer for airflow and levelling. Alternative: drainage boards with sand and gravel beds for unit masonry designed to provide permeable layer and levelling.

(7) Pavers: Designed to support predicted live loads, maximum size 600mm (24") by 600mm (24").

2 WORK BY OTHERS

(A) Acceptable Deck: Concrete slab depicted.

NOTE: Refer to RoofStar Guarantee Standards for additional requirements.



RoofStar Guarantee Standards for Waterproofing Plazas, Promenades & Terraces

Back to Waterproofing Construction Details

Back to Construction Details