(2) [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPMEMBRANE '''Primary Waterproofing Membrane''']: Fully adhered to acceptable substrates (concrete slab shown), installed as per [[RoofStar Guarantee Standards for Waterproofing|'''RoofStar Guarantee Standards for Waterproofing Plazas, Promenades & Terraces''']] and Membrane Manufacturer's installation specifications.<b> </b> | (2) [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPMEMBRANE '''Primary Waterproofing Membrane''']: Fully adhered to acceptable substrates (concrete slab shown), installed as per [[RoofStar Guarantee Standards for Waterproofing|'''RoofStar Guarantee Standards for Waterproofing Plazas, Promenades & Terraces''']] and Membrane Manufacturer's installation specifications.<b> </b> | ||
− | (3) [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPPROTECTION '''Protection Board/Mat''']: Proprietary membrane protection board or mat approved by membrane manufacturer, compatible with waterproofing membrane system, and compliant with [[RoofStar Guarantee Standards for Waterproofing#WPPROTECTION|''' | + | (3) [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPPROTECTION '''Protection Board/Mat''']: Proprietary membrane protection board or mat approved by membrane manufacturer, compatible with waterproofing membrane system, and compliant with Section 8, [[RoofStar Guarantee Standards for Waterproofing#WPPROTECTION|'''Membrane Protection''']]. |
(4) [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPINSULATION '''Insulation''']: Type 4 extruded polystyrene insulation | (4) [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPINSULATION '''Insulation''']: Type 4 extruded polystyrene insulation |
Revision as of 18:33, 12 October 2016
RoofStar Guarantee Standards are blue-linked |
1 WORK INCLUDED
(1) Membrane Primer or Adhesive: proprietary primer or adhesive, application method and quantities for substrate type as directed by membrane manufacturer's published application specifications.
(2) Primary Waterproofing Membrane: Fully adhered to acceptable substrates (concrete slab shown), installed as per RoofStar Guarantee Standards for Waterproofing Plazas, Promenades & Terraces and Membrane Manufacturer's installation specifications.
(3) Protection Board/Mat: Proprietary membrane protection board or mat approved by membrane manufacturer, compatible with waterproofing membrane system, and compliant with Section 8, Membrane Protection.
(4) Insulation: Type 4 extruded polystyrene insulation
(5) Filter Mat: Synthetic water permeable fabric.
2 WORK BY OTHERS
(A) Acceptable Deck: Concrete slab shown
(B) Drain Assembly: Proprietary cast iron waterproofing/roof drain assembly
(C) Pedestals Proprietary paver pedestals designed to carry predicted live loads and accepted by the insulation manufacturer.
(D) Concrete Paver
NOTE: Refer to RoofStar Guarantee Standards for additional requirements.
Back to Waterproofing Application