Difference between revisions of "WP Details:F1.7.12 (Deck Drain - Unit Masonry on Pedestal Supports)"

Jump to: navigation, search

Difference between revisions of "WP Details:F1.7.12 (Deck Drain - Unit Masonry on Pedestal Supports)"

Line 1: Line 1:
<hr>
+
<div class="panel panel-success">
[[File:9.6.12.jpg]]
+
<div class="panel-heading"><big>'''Waterproofing Details for Plazas, Promenades and Terraces'''</big></div>
 
+
<div class="panel-body">
 +
<div class="col-md-6">
 +
<div style="text-align:center; vertical-align:center">
 +
[[File:9.6.12.jpg|class=img-responsive]]
 +
</div>
 +
</div><!-- COL-MD-6 -->
  
 +
<div class="col-md-6">
 
=== WORK INCLUDED ===
 
=== WORK INCLUDED ===
 
 
(1) <b>Membrane Primer or Adhesive: </b>proprietary primer or adhesive, application method and quantities for substrate type as directed by membrane manufacturer's published application specifications.  
 
(1) <b>Membrane Primer or Adhesive: </b>proprietary primer or adhesive, application method and quantities for substrate type as directed by membrane manufacturer's published application specifications.  
  
Line 18: Line 23:
  
 
=== WORK BY OTHERS ===
 
=== WORK BY OTHERS ===
 
 
(A) <b>Acceptable Deck</b>: Concrete slab shown (B) <b>Drain Assembly: </b>Proprietary cast iron waterproofing/roof drain assembly
 
(A) <b>Acceptable Deck</b>: Concrete slab shown (B) <b>Drain Assembly: </b>Proprietary cast iron waterproofing/roof drain assembly
  
Line 24: Line 28:
  
 
(D) <b>Concrete Paver</b>  
 
(D) <b>Concrete Paver</b>  
 +
</div><!-- COL-6-MD -->
 +
</div><!-- PANEL BODY -->
 +
</div><!-- PANEL -->
  
<b><i>NOTE: </i> Refer to<i> RGC Guarantee Standards E </i>for additional requirements.</b>
+
'''NOTE''': Refer to '''''RoofStar Guarantee Standards''''' for additional requirements.
  
 
<hr>
 
<hr>
Line 31: Line 38:
  
  
[[Section:F. Application: Waterproofing Plazas, Promenades and Terraces|<i class="fa fa-chevron-circle-left fa-2x" ></i> Back to ''Waterproofing Application'']]
 
  
[[Waterproofing Construction Details|<i class="fa fa-chevron-circle-left fa-2x" ></i> Back to ''Waterproofing Construction Details'']]
+
[[Section:F. Application: Waterproofing Plazas, Promenades and Terraces|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Waterproofing Application'']]
 +
 
 +
[[Waterproofing Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Waterproofing Construction Details'']]
  
[[Section:G. Construction Details|<i class="fa fa-chevron-circle-left fa-2x" ></i> Back to ''Construction Details'']]
+
[[Section:G. Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Construction Details'']]

Revision as of 21:53, 19 August 2016

Waterproofing Details for Plazas, Promenades and Terraces

9.6.12.jpg

1 WORK INCLUDED

(1) Membrane Primer or Adhesive: proprietary primer or adhesive, application method and quantities for substrate type as directed by membrane manufacturer's published application specifications.

(2) Primary Waterproofing Membrane: Fully adhered to acceptable substrates (concrete slab shown), installed as per RoofStar Guarantee Standards E and Membrane Manufacturer's installation specifications.

(3) Protection Board/Mat: Proprietary membrane protection board or mat approved by membrane manufacturer, compatible with waterproofing membrane system, and compliant with RGC Guarantee Standards E.

(4) Insulation: Type 4 extruded polystyrene insulation

(5) Filter Mat: synthetic water permeable fabric.


2 WORK BY OTHERS

(A) Acceptable Deck: Concrete slab shown (B) Drain Assembly: Proprietary cast iron waterproofing/roof drain assembly

(C) Pedestals Proprietary paver pedestals designed to carry predicted live loads and accepted by the insulation manufacturer.

(D) Concrete Paver

NOTE: Refer to RoofStar Guarantee Standards for additional requirements.




Back to Waterproofing Application

Back to Waterproofing Construction Details

Back to Construction Details