<div class="panel-heading"><big>'''Waterproofing Details for Plazas, Promenades and Terraces'''</big></div>
 
<div class="panel-heading"><big>'''Waterproofing Details for Plazas, Promenades and Terraces'''</big></div>
Line 12: Line 15:
 
(1) <b>Membrane Primer or Adhesive: </b>proprietary primer or adhesive, application method and quantities for substrate type as directed by membrane manufacturer's published application specifications.  
 
(1) <b>Membrane Primer or Adhesive: </b>proprietary primer or adhesive, application method and quantities for substrate type as directed by membrane manufacturer's published application specifications.  
  
(2) <b>Primary Waterproofing Membrane: </b>Fully adhered to acceptable substrates (concrete slab shown), installed as per {{hilite | <i>RoofStar Guarantee
+
(2) <b>Primary Waterproofing Membrane: </b>Fully adhered to acceptable substrates (concrete slab shown), installed as per [[RoofStar Guarantee Standards for Waterproofing|'''RoofStar Guarantee Standards for Waterproofing Plazas, Promenades & Terraces''']] and Membrane Manufacturer's installation specifications.<b> </b>  
Standards E </i> || 2016-November-19 }} and Membrane Manufacturer's installation specifications.<b> </b>  
 
  
(3) <b>Protection Board/Mat: </b>Proprietary membrane protection board or mat approved by membrane manufacturer, compatible with waterproofing membrane system, and compliant with {{hilite | RGC Guarantee Standards <b>E.</b> || 2016-November-19 }}
+
(3) <b>Protection Board/Mat: </b>Proprietary membrane protection board or mat approved by membrane manufacturer, compatible with waterproofing membrane system, and compliant with [[RoofStar Guarantee Standards for Waterproofing#WPPROTECTION|'''8. Membrane Protection''']].
  
 
(4) <b>Insulation</b>: Type 4 extruded polystyrene insulation
 
(4) <b>Insulation</b>: Type 4 extruded polystyrene insulation
Line 22: Line 24:
  
 
=== WORK BY OTHERS ===
 
=== WORK BY OTHERS ===
(A) <b>Acceptable Deck</b>: Concrete slab shown (B) <b>Drain Assembly: </b>Proprietary cast iron waterproofing/roof drain assembly
+
(A) <b>Acceptable Deck</b>: Concrete slab shown  
 +
 
 +
(B) <b>Drain Assembly: </b>Proprietary cast iron waterproofing/roof drain assembly
  
 
(C) <b>Pedestals </b>Proprietary paver pedestals designed to carry predicted live loads and accepted by the insulation manufacturer.
 
(C) <b>Pedestals </b>Proprietary paver pedestals designed to carry predicted live loads and accepted by the insulation manufacturer.

Revision as of 16:28, 1 September 2016

RoofStar Guarantee Standards are blue-linked
Waterproofing Details for Plazas, Promenades and Terraces

9.6.12.jpg

1 WORK INCLUDED

(1) Membrane Primer or Adhesive: proprietary primer or adhesive, application method and quantities for substrate type as directed by membrane manufacturer's published application specifications.

(2) Primary Waterproofing Membrane: Fully adhered to acceptable substrates (concrete slab shown), installed as per RoofStar Guarantee Standards for Waterproofing Plazas, Promenades & Terraces and Membrane Manufacturer's installation specifications.

(3) Protection Board/Mat: Proprietary membrane protection board or mat approved by membrane manufacturer, compatible with waterproofing membrane system, and compliant with 8. Membrane Protection.

(4) Insulation: Type 4 extruded polystyrene insulation

(5) Filter Mat: synthetic water permeable fabric.

2 WORK BY OTHERS

(A) Acceptable Deck: Concrete slab shown

(B) Drain Assembly: Proprietary cast iron waterproofing/roof drain assembly

(C) Pedestals Proprietary paver pedestals designed to carry predicted live loads and accepted by the insulation manufacturer.

(D) Concrete Paver

NOTE: Refer to RoofStar Guarantee Standards for additional requirements.