Difference between revisions of "WP Details:F1.7.6 (Walls - Planter Pre-Curb Wall)"

Jump to: navigation, search

Difference between revisions of "WP Details:F1.7.6 (Walls - Planter Pre-Curb Wall)"

Line 16: Line 16:
 
=== WORK INCLUDED ===
 
=== WORK INCLUDED ===
  
(1) <b>Primary Waterproofing Membrane</b>: Fully adhered to acceptable substrates (concrete slab depicted), installed as per <i>RGC Guarantee Standards E </i>and Membrane Manufacturer's installation specifications.  
+
(1) [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPMEMBRANE '''Primary Waterproofing Membrane''']: Fully adhered to acceptable substrates (concrete slab depicted), installed as per '''''RoofStar Guarantee Standards''''' and Membrane Manufacturer's installation specifications.  
  
 
(2) <b>Membrane Primer or Adhesive</b>: proprietary primer or adhesive, application and quantities as directed by membrane manufacturers published application specifications.  
 
(2) <b>Membrane Primer or Adhesive</b>: proprietary primer or adhesive, application and quantities as directed by membrane manufacturers published application specifications.  
  
(3) <b>Pre-Curb (Start-Up Curb) Membrane Flashing</b>: Two ply of membrane flashing (elastomeric, plastomeric, or modified bituminous) completely enclosing pre-curb and installed as per membrane manufacturer's published application specifications. Install membrane reinforcement gussets at all corner detail transitions.
+
(3) [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPPLANTERS '''Pre-Curb (Start-Up Curb) Membrane Flashing''']: Two ply of membrane flashing (elastomeric, plastomeric, or modified bituminous) completely enclosing pre-curb and installed as per membrane manufacturer's published application specifications. Install membrane reinforcement gussets at all corner detail transitions.
  
(4) <b>Proprietary liquid membrane flashing System</b>: RGC accepted Liquid Membrane Flashing System(s) (Refer to RPM Section2.2 for accepted systms. Install as per Manufacturer's published instructions.
+
(4) <b>Proprietary liquid membrane flashing System</b>: RoofStar-accepted Liquid Membrane Flashing System(s) (Refer to [[Flexible Membrane Roofing Systems: Liquid Membrane Flashing Systems|'''Liquid Membrane Flashing Systems''']] in the Accepted Materials section of this Manual). Install as per Manufacturer's published instructions.
  
(5) <b>Inside Planter Wall Membrane Flashing: </b>Adhered according to manufacturer's specifications. Carry membrane flashing plies to reglet termination near top of planter wall (stagger membrane seal minimum 300mm (6").  
+
(5) [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPSTRIPPING '''Inside Planter Wall Membrane Flashing''']: Adhered according to manufacturer's specifications. Carry membrane flashing plies to reglet termination near top of planter wall (stagger membrane seal minimum 300mm (6").  
  
(6) <b>Reglet Metal Counter Flashing: </b>As required by <i>RGC Guarantee Standards E</i>.  
+
(6) [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPREGLET '''Reglet Metal Counter Flashing''']
(7) <b>Plaza Deck Assembly: </b>Extruded polystyrene insulation and filter mat (optional) over primary waterproofing membrane. Concrete pavers placed above pre-curb membrane flashing height on proprietary pedestals. <b>Note:</b> membrane and metal wall counter flashing is not required above pre-curb membrane flashing on plaza deck side of planter walls.  
+
 
 +
(7) [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPDECK '''Plaza Deck Assembly''']: Extruded polystyrene insulation and filter mat (optional) over primary waterproofing membrane. Concrete pavers placed above pre-curb membrane flashing height on proprietary pedestals. <b>Note:</b> membrane and metal wall counter flashing is not required above pre-curb membrane flashing on plaza deck side of planter walls.  
  
  
 
=== RELATED WORK BY OTHERS ===
 
=== RELATED WORK BY OTHERS ===
  
(A) <b>Acceptable Deck</b>: Concrete slab shown  
+
(A) [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPDECK '''Acceptable Deck''']: Concrete slab shown  
  
(B) <b>Pre- Curb: </b>Minimum of 100mm (4") in height above concrete deck, smooth dry and clean.
+
(B) [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPPLANTERS '''Pre-Curb''']: Minimum of 100mm (4") in height above concrete deck, smooth dry and clean.
  
(C) <b>Cast over Concrete Planter Wall: </b>Form on top of membrane sealed Pre-curbs or Start-up curbs<b>.</b>  
+
(C) [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPPLANTERS '''Pre-Curb''']: Form on top of membrane sealed Pre-curbs or Start-up curbs<b>.</b>  
  
 
(D) <b>Re-Bar: </b>Placed at centre of Pre-curb.
 
(D) <b>Re-Bar: </b>Placed at centre of Pre-curb.
  
(E) <b>Reglet</b>: Premanufactured purpose-made reglet cast in concrete wall or saw-cut.  
+
(E) [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPREGLET '''Reglet''']: Pre-manufactured purpose-made reglet cast in concrete wall or saw-cut.  
  
 
(F) <b>Alternate Termination: </b>Horizontal Reglet<b> </b>alternative to premanufactured purpose-made reglet cast in concrete wall or saw-cut on vertical surface of inside planter walls.  
 
(F) <b>Alternate Termination: </b>Horizontal Reglet<b> </b>alternative to premanufactured purpose-made reglet cast in concrete wall or saw-cut on vertical surface of inside planter walls.  

Revision as of 17:40, 12 October 2016

RoofStar Guarantee Standards are blue-linked
SBS Details

D1.7.6-5 (1).jpg

D1.7.6-5 (2).jpg

1 WORK INCLUDED

(1) Primary Waterproofing Membrane: Fully adhered to acceptable substrates (concrete slab depicted), installed as per RoofStar Guarantee Standards and Membrane Manufacturer's installation specifications.

(2) Membrane Primer or Adhesive: proprietary primer or adhesive, application and quantities as directed by membrane manufacturers published application specifications.

(3) Pre-Curb (Start-Up Curb) Membrane Flashing: Two ply of membrane flashing (elastomeric, plastomeric, or modified bituminous) completely enclosing pre-curb and installed as per membrane manufacturer's published application specifications. Install membrane reinforcement gussets at all corner detail transitions.

(4) Proprietary liquid membrane flashing System: RoofStar-accepted Liquid Membrane Flashing System(s) (Refer to Liquid Membrane Flashing Systems in the Accepted Materials section of this Manual). Install as per Manufacturer's published instructions.

(5) Inside Planter Wall Membrane Flashing: Adhered according to manufacturer's specifications. Carry membrane flashing plies to reglet termination near top of planter wall (stagger membrane seal minimum 300mm (6").

(6) Reglet Metal Counter Flashing

(7) Plaza Deck Assembly: Extruded polystyrene insulation and filter mat (optional) over primary waterproofing membrane. Concrete pavers placed above pre-curb membrane flashing height on proprietary pedestals. Note: membrane and metal wall counter flashing is not required above pre-curb membrane flashing on plaza deck side of planter walls.


2 RELATED WORK BY OTHERS

(A) Acceptable Deck: Concrete slab shown

(B) Pre-Curb: Minimum of 100mm (4") in height above concrete deck, smooth dry and clean.

(C) Pre-Curb: Form on top of membrane sealed Pre-curbs or Start-up curbs.

(D) Re-Bar: Placed at centre of Pre-curb.

(E) Reglet: Pre-manufactured purpose-made reglet cast in concrete wall or saw-cut.

(F) Alternate Termination: Horizontal Reglet alternative to premanufactured purpose-made reglet cast in concrete wall or saw-cut on vertical surface of inside planter walls.

NOTE: Refer to RoofStar Guarantee Standards for additional requirements.




Back to Waterproofing Application

Back to Waterproofing Construction Details

Back to Construction Details